Who is Piller and what does it make?
Piller makes high-power rotary UPS systems and energy storage solutions, used where a power interruption of just a few milliseconds can stop a critical process. From the Piller range we can quote UNIBLOCK rotary UPS units, critical power modules with a flywheel, M+ and CleanSource static UPS series, and dynamic power stabilisation systems under the SHIELDX brand.
Piller specialises in high-power uninterruptible supply with rotary technology: the UNIBLOCK series covers power ratings from 150 kW up to 50 MW, while the flywheel critical power modules range from 225 kW to 2.4 MW, a typical span for large data centres or continuous industrial plants. The M+ and CleanSource static UPS series cover 250 to 1,200 kW, for applications where a classic static UPS remains the right solution.
For installations in Romania, the Piller range makes sense for data centres, hospitals, banking facilities and critical infrastructure where continuity of the electrical supply cannot depend only on a diesel generator with a start-up time of several seconds.
What do we supply from the Piller range?
| Product | Description |
|---|---|
| UNIBLOCK Series Rotary UPS | Rotary UPS system, with power ratings from 150 kW up to 50 MW, used to protect continuous industrial plants and large data centres. It removes the need for chemical batteries, the backup energy source being the kinetic energy stored directly in the rotating system. |
| Critical Power Modules with Flywheel (CPM) | Compact modules with a flywheel, available in power ratings from 225 kW to 2.4 MW, which bridge the interval between a voltage drop and the start of a standby generator, without the chemical batteries of a static UPS. |
| M+ and CleanSource Series Static UPS | Static UPS systems with power ratings from 250 to 1,200 kW, suited to applications where rotary technology is not justified economically or technically, but continuity of supply remains critical. |
| SHIELDX Dynamic Stabilisation System | Battery-free dynamic power stabilisation system, designed mainly for data centres with AI-type loads supplied from isolated local generation, where sudden load swings of the order of megawatts occur. |
Why Piller?
- UNIBLOCK rotary UPS series, from 150 kW to 50 MW, for industrial plants and high-power data centres
- Critical power modules with a flywheel (225 kW–2.4 MW), without the chemical batteries of a classic static UPS
- M+ and CleanSource static UPS series (250-1,200 kW) for applications where rotary technology is not needed
- SHIELDX dynamic stabilisation system, battery-free, for loads with sudden power swings
- Coverage of eight critical sectors, from data centres to aviation and banking systems
Which Piller codes and series are requested most often?
| Code | Description |
|---|---|
| UNIBLOCK | Rotary UPS system with kinetic energy storage, high power |
| UB-V | Electrically coupled UPS, from 1,100 kVA to 3,600 kVA, with battery or kinetic storage, for hyperscale data centres |
| M+ | Modular static UPS, hot-swappable components for fast maintenance |
| APOSTAR | Static UPS from 3 to 500 kVA, for general applications |
| CPM | Critical power module with integrated flywheel, from 225 kW to 2.4 MW |
| SHIELDX | Battery-free dynamic stabilisation system for variable loads |
| APOTRANS | Static transfer switch, from 25 A to 1600 A |
| DeRUPS | Configuration with an integrated diesel generator alongside the UNIBLOCK rotary UPS |
| CleanSource | Static UPS with flywheel, power range from 250 to 1200 kW |
| Frequency Converters | Frequency converters for adapting the grid to 50 or 60 Hz |
| Isolated Parallel | System configuration combining isolated redundancy with parallel redundancy |
Where is Piller equipment used?
- Data centres — supply continuity for servers and critical IT infrastructure
- Industrial production — protection against interruptions for continuous-process lines
- Healthcare — uninterrupted supply for critical medical equipment
- Banking and finance — continuity for transaction-processing infrastructure
- Telecommunications — protection for network equipment and exchanges
- Aviation — critical supply for aviation applications
- Marine — critical power systems for naval applications
- Energy — protected supply for energy-sector infrastructure
How do we supply Piller in Romania?
What we present about Piller is based on the manufacturer's technical documentation and limited to what it states explicitly. We bring Piller systems in to order; the lead time is counted from confirmation and can be longer depending on the brand, the specifications and the project configuration. For a correct quotation we need the required power, the application type (data centre, industrial, marine) and the installation space requirements. Equipment of this complexity is not kept on the shelf: each project is checked individually before quotation.
Piller's founding year, headquarters city and group structure are given only on the basis of published data.
Frequently asked questions about Piller
What is a Piller UNIBLOCK rotary UPS system?
UNIBLOCK is a rotary uninterruptible power supply system that uses a flywheel to store kinetic energy and release it instantly in a voltage drop. The range covers power ratings from 150 kW up to 50 MW and is used in data centres, hospitals and heavy industry. Unlike static UPS units with batteries, UNIBLOCK reduces electrochemical components and offers a very short transfer response time.
Do you bring Piller equipment to order in Romania?
Piller systems are brought in to firm order, according to the exact configuration required by the project; the range is not kept on the shelf, and for systems of this complexity the lead time can be longer depending on the brand and specifications, and is confirmed after the project analysis. We refer to the manufacturer's technical documentation to confirm the suitable UPS or static switch variant. We recommend sending the required power and the type of critical load for a correct quotation.
What is the difference between the M+ static UPS and the UNIBLOCK rotary system at Piller?
M+ is a modular static UPS, with hot-swap modules that allow quick replacement without shutting down the load, suitable for data centres with limited space. UNIBLOCK is a rotary system with a flywheel, which offers protection at very high power ratings and reduces dependence on chemical batteries. The choice depends on the total power required, the available space and the end user's maintenance policy.
What information do I send for a Piller UPS quotation?
We need the required critical power in kW or kVA, the type of load supplied, the desired autonomy time and the preferred redundancy configuration, isolated or parallel. For existing installations, a description of the electrical switchboard and the available space helps place the request correctly in the UNIBLOCK, M+ or CPM range, avoiding over- or under-sizing of the final system supplied.
How do I request a Piller quotation?
Send the Piller code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Piller Group GmbH (manufacturer documentation)