Maxitrol supplier in Romania
For Maxitrol we quote gas pressure regulators from the RV series, Selectra and EXA electronic modulation systems, combination valves GV, CV and GW and filters GF1000 and HF2000; we need the gas, the inlet pressure and the connection size.
Headquarters: Southfield, Michigan, USA
Who is Maxitrol and what does it make?
Maxitrol Company, headquartered in Southfield, Michigan, USA, makes control and safety equipment for gas installations: electronic gas modulation systems, pressure regulators, combination control valves, safety devices and gas and air filters.
Among the regulators, the RV series splits in two. The versions with a rubber seat and poppet valve (RV12, RV20, RV47, RV48) are sized for connections from Rp 1/8 to Rp 3/4 and are used on main burner and pilot flame loads, at pressures of up to 3.4 kPa. The linear-flow versions (RV52, RV53, RV61, RV81, RV91, RV111) cover connections from Rp ½ to Rp 3, are non-lock-up regulators, with high flows at low inlet pressures, for commercial and industrial gas equipment. The series is completed by models 325, 325-L, RS/210, RZ/210Z, 220 and SR.
Selectra and EXA are the flame modulation families, with modulating and modulating-regulating valves, and the combination valves are in the GV, CV and GW series. The GF1000 filters (flanged, DN40–DN65) and HF2000 retain particles larger than 50 microns, upstream of regulators and shut-off valves. For a quotation, the gas, the inlet pressure, the flow, the connection size and the gas family under EN 437 matter.
What do we supply from the Maxitrol range?
| Product | Description |
|---|---|
| RV pressure regulators | A series with versions RV12, RV20, RV47 and RV48 (rubber seat, up to 3.4 kPa) and RV52, RV53, RV61, RV81, RV91 and RV111 (linear flow, from Rp ½ to Rp 3), for natural gas, LPG and mixtures. |
| Selectra and EXA modulation systems | Modulating and modulating-regulating valves with control electronics, for continuous flame adjustment. Series 44R is intended for space heating with direct-fired appliances and can be fitted to existing installations. |
| Combination valves GV, CV and GW | Combination gas control valves, with a gas-water version in the GW series. They are completed by shut-off devices and by automatic valves from the AV series. |
| Gas and air filters GF1000 and HF2000 | GF1000 has flanged versions DN40, DN50 and DN65, and HF2000 covers threaded connections from ½ inch to 2 inch and flanged connections from DN25 to DN150. They retain particles larger than 50 microns. |
Why Maxitrol?
- RV regulators with a rubber seat or linear flow — the version is chosen by flow and inlet pressure
- Connections from Rp 1/8 to Rp 3 in the RV series — the same family covers everything from pilot lines to main burner lines
- Compatibility with gases from families 1, 2 and 3 under EN 437 — natural gas, LPG and gas-air mixtures
- Selectra and EXA modulation systems — electronic flame control on direct-fired heating installations
- GF1000 and HF2000 filters that retain particles larger than 50 microns — they protect the regulators and shut-off valves downstream
Which Maxitrol codes and series are requested most often?
| Code | Description |
|---|---|
| RV12 | Regulator with rubber seat, Rp 1/8 connection |
| RV20 | Regulator with rubber seat, Rp 1/4 or Rp 3/8 connection |
| RV47 | Regulator with rubber seat, Rp 3/8 or Rp 1/2 connection |
| RV48 | Regulator with rubber seat, Rp 1/2 or Rp 3/4 connection |
| RV52 | Linear-flow regulator, Rp ½ or Rp ¾ connection |
| RV53 | Linear-flow regulator, Rp ¾ or Rp 1 connection |
| RV61 | Linear-flow regulator, Rp 1 or Rp 1 ¼ connection |
| RV81 | Linear-flow regulator, Rp 1 ¼ or Rp 1 ½ connection |
| RV91 | Linear-flow regulator, Rp 2 connection |
| RV111 | Linear-flow regulator, Rp 2 ½ or Rp 3 connection |
| GF1000 | Gas and air filter, flanged versions DN40–DN65 |
| HF2000 | Gas and air filter, threaded and flanged connections |
Where is Maxitrol equipment used?
- Industrial and commercial gas heating — RV regulators and Selectra modulation systems
- Industrial burners — combination valves and filters to protect the downstream fittings
- Heating of industrial spaces — Selectra modulation systems for direct-fired appliances
- Gas-fired thermal processes — GF1000 and HF2000 filters upstream of regulators
How do we supply Maxitrol in Romania?
We can quote Maxitrol regulators, filters and modulation systems from the series it makes. For a correct quotation, send the full code from the regulator or valve (for example RV52 or GF1000MF50), the gas and its EN 437 family, the inlet and outlet pressure required, the flow, the connection size (Rp or DN) and whether the unit is on the main burner or the pilot. For modulation systems add the series and the type of installation. After checking the code and the pressures, we confirm the lead time in the quotation.
Uses on installations subject to local gas regulations are checked in the quotation, based on the gas family and the pressures received.
Frequently asked questions about Maxitrol
What are the RV, Selectra, EXA and GF1000 series at Maxitrol?
The RV series comprises the gas pressure regulators, Selectra and EXA are the modulation systems with control electronics for continuous flame adjustment, and GF1000 is the gas and air filter, with flanged versions DN40, DN50 and DN65. The range also includes the combination valves GV, CV and GW.
How do I choose the right RV regulator?
Versions RV12, RV20, RV47 and RV48 have a rubber seat, up to 3.4 kPa, for small lines. Versions RV52–RV111 have linear flow, from Rp ½ to Rp 3, for high flows at low inlet pressures. Send the flow, the pressure and the connection.
Is Maxitrol equipment supplied in Romania, and how quickly?
Maxitrol equipment is supplied to order for you, usually in 1–4 weeks, longer for special configurations. A Maxitrol regulator can ship in 24–72 h when the item is in stock, locally or at the supplier. We confirm the exact lead time in the quotation, once the code is fixed.
Can I replace an existing gas regulator or filter?
Yes, after we compare the code on the body, the connection (Rp or DN), the inlet pressure, the flow and the EN 437 gas family. The GF1000 and HF2000 filters retain particles larger than 50 microns. Send a photo of the nameplate.
What must I send for a quotation on a Maxitrol regulator?
Send the full code, the gas and its family, the inlet and outlet pressure, the flow, the connection size and the place of installation, main burner or pilot. For Selectra systems add the series and the type of appliance on which it is fitted.
How do I request a Maxitrol quotation?
Send the Maxitrol code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Maxitrol Company (manufacturer documentation)