NR Electric supplier in Romania
PCS protection relays and PCS-9700 substation automation compatible with IEC 61850
Who is NR Electric and what does it make?
NR Electric Co., Ltd. is a Chinese manufacturer of protection relays, substation automation systems and equipment for digital substations. The PCS series covers line, busbar, transformer, circuit breaker, generator, feeder, capacitor and motor protection, arc protection, plus field units, RTUs, protocol converters, satellite-synchronised clocks and industrial Ethernet switches.
The PCS-9700 system is the automation solution for substations, power plants and industrial sites, from distribution up to extra-high voltage. The architecture has four levels: station (HMI), network (single or dual, in a ring), field (field units, relays and disturbance recorders) and, optionally, the process level with electronic current and voltage transformers, merging units and circuit breaker controllers. The system is IEC 61850 compatible and supports IEC 61850-9-2 Sampled Values and GOOSE over fibre. Through the PCS-9799 Station Manager it adds IEC 60870-5-101/104 and 103, Modbus and DNP3.0.
The equipment category is used in substations and in power plants, including the modernisation of electromechanical relays or control systems. A correct quotation is based on the protection functions required, the number of bays and the protocols imposed by the dispatch centre. The line protections include PCS-902 (distance), PCS-931 (differential) and PCS-924 for the T zone in one-and-a-half breaker configurations, and for busbars there is PCS-915, centralised or distributed. For transformers, PCS-978 covers units with several windings, and PCS-9671S goes up to 110 kV.
What do we supply from the NR Electric range?
| Product | Description |
|---|---|
| PCS-902 and PCS-931 — line protection | PCS-902 is a distance relay for overhead lines and cables, with automatic reclosing; PCS-931 is a line differential relay with built-in distance. The S versions combine main and backup protection. |
| PCS-915 — busbar protection | PCS-915IC and SC are centralised, up to 25 bays; PCS-915ID and SD are distributed, with a central unit and up to 32 field units connected by optical fibre. |
| PCS-978 and PCS-9671 — transformer protection | PCS-978 protects multi-winding transformers, autotransformers and shunt reactors; PCS-9671 is a compact relay for two-winding transformers, with differential and restricted earth fault protection. |
| PCS-9700 — substation automation | System with HMI, PCS-9705 field units, PCS-9710 RTU, PCS-9799 Station Manager, PCS-9794 converter, PCS-9785 clock and PCS-9882 and PCS-9884 Ethernet switches with PRP/HSR. |
Why NR Electric?
- Range of PCS-902 and PCS-931 line protections — distance and differential, with S versions for main and backup protection in the same relay
- PCS-915 busbar protection — centralised for up to 25 bays or distributed, with a central unit and up to 32 field units over fibre
- PCS-9700 system compatible with IEC 61850, with process bus through Sampled Values and GOOSE over fibre
- Transformer protections from PCS-9671 and PCS-9671S (the latter for 110 kV and below) to PCS-978, for multi-winding transformers, autotransformers and reactors
- PCS-9794 protocol converter for integrating third-party IEDs — adds private NR, CDT and configurable protocols
Which NR Electric codes and series are requested most often?
| Code | Description |
|---|---|
| PCS-902 | Distance relay for overhead lines and cables |
| PCS-902S | Distance relay with main and backup protection |
| PCS-931 | Line differential relay with distance |
| PCS-931S | Line differential relay, main and backup |
| PCS-924 | Differential relay for the T zone, 1½ and ring configurations |
| PCS-915IC | Busbar protection, centralised, up to 25 bays |
| PCS-915ID | Busbar protection, distributed, up to 32 field units |
| PCS-978 | Transformer protection with several windings |
| PCS-9671 | Compact transformer protection with two windings |
| PCS-974 | Auxiliary relay for non-electrical protections, 16 inputs |
| PCS-9700 | Automation system for substations |
| PCS-9705 | Field control unit |
| PCS-9710 | Remote terminal unit (RTU) |
| PCS-9794 | Protocol converter |
| PCS-9884 | Managed Ethernet switch with HSR and PRP |
Where is NR Electric equipment used?
- Substations — line, busbar and transformer protection and substation automation
- Power plants — control and protection, including plant control systems
- Digital substations — modernisation of conventional substations with merging units and process bus
- Industrial systems — automation and protection for in-house substations
- Communication networks for substations — Ethernet switches with PRP and HSR
How do we supply NR Electric in Romania?
We can quote NR Electric relays from the PCS series, field units and accessories, based on your protection scheme. Supplied to order, usually in 1–4 weeks; for complete automation systems, the lead time can be longer. For a correct quotation send us the existing model (for example PCS-931 or PCS-915), the ANSI functions required, the number of bays, the rated currents and voltages, the protocols to the dispatch centre and, for modernisations, the single-line diagram and the make of the relays being replaced. The exact lead time is confirmed in the quotation.
Equivalence with the relays of other makes is established on the basis of functions, terminals and the mounting diagram.
Frequently asked questions about NR Electric
What products does NR Electric make?
NR Electric makes PCS series protection relays (lines, busbars, transformers, generators, feeders, motors), PCS-9700 substation automation systems, field units, RTUs, protocol converters, GNSS clocks and Ethernet switches for substations, as well as equipment for digital substations.
How do I choose between centralised and distributed PCS-915?
The IC and SC versions are centralised, for up to 25 bays, while ID and SD are distributed, with a central unit and up to 32 field units over fibre. The choice depends on the number of bays and the distances in the substation. Send us the diagram.
Can you supply NR Electric equipment in Romania, and within what lead time?
Yes, supplied to order. For items, the lead time on order is usually 1–4 weeks; complete systems may need longer, and the exact lead time is confirmed in the quotation.
Can I replace an existing line relay with the PCS-931?
It is checked on the type of protection (distance or differential), the communication channels for teleprotection, the rated currents and voltages and the number of inputs and outputs. Equivalence with other makes is established on the basis of this data and after a check.
What data do I need to send for a PCS-9700 system quotation?
State the number of bays and voltage levels, the existing IEDs with their protocols, whether the process level is needed (SV, GOOSE), the protocols to the dispatch centre and the network redundancy requirements.
How do I request a NR Electric quotation?
Send the NR Electric code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.