OMEGA AIR supplier in Romania
For OMEGA AIR we quote adsorption dryers A-DRY, X-DRY and HP-DRY, refrigeration dryers RDP, RDT and RDHP, AAF and BF filters and EMD, TD M and AOK condensate drains; the item is identified by series and flow rate.
Headquarters: Ljubljana, Slovenia
Who is OMEGA AIR and what does it make?
OMEGA AIR is a company from Ljubljana, Slovenia, that makes compressed air treatment equipment: dryers, filters and filter housings, separators and condensate drains, as well as heat exchangers for air cooling. They all serve the same purpose: to remove water, oil and particles from the air network before they reach machinery, pneumatic tools or sensitive processes.
The dryers are divided by working principle. The refrigeration dryers include the RDP and RDP ES series, with EMD electronic drain, the RDT series, with timed drain, the RDL series and the RDHP series for high pressures. The heatless-regenerated adsorption dryers are A-DRY, A-DRY TAC with an activated carbon tower, modular X-DRY, B-DRY, F-DRY, HP-DRY for high pressure and PICO-DRY. The range also includes heat-regenerated, hybrid, membrane and breathing air dryers, plus adsorbents.
In filtration, the AAF series retains solid particles, water and oil aerosols, BF is a welded carbon steel housing, and AAFs is silicone-free, for paint shops. For high pressures there are the CHP carbon steel and IHP stainless steel housings, and for sterile processes the SPF and SF stainless steel filters. Condensate drains are electronic (EMD, IED), timed (TD M), automatic mechanical (AOK) or manual (MCD). For a quotation, what matters is the flow rate, working pressure, inlet temperature and the required outlet dew point.
What do we supply from the OMEGA AIR range?
| Product | Description |
|---|---|
| Heatless-regenerated adsorption dryers | The A-DRY series, A-DRY TAC with activated carbon tower, modular X-DRY, B-DRY and B-DRY TAC, F-DRY, HP-DRY for high pressure and PICO-DRY. The adsorbent columns work alternately, and the dried air reaches a low dew point for instrumentation, paint shops and the food industry. |
| RDP, RDT, RDL and RDHP refrigeration dryers | The RDP and RDP ES series come with EMD electronic drain, RDT with timed drain, and RDHP is for high-pressure compressed air. They cool the air to condense the vapour and are the usual solution when a positive dew point is enough. |
| Filters and filter housings | AAF for particles, water and oil aerosols, BF in welded carbon steel, AAFs silicone-free, CHP and IHP for high pressures, PF, SPF and SF in stainless steel for processes and sterile air, P-VAC for vacuum pump protection. The filter elements are chosen by filtration grade. |
| Condensate drains | The EMD and IED families are electronic, TD M and TD 420M are timed, AOK is automatic mechanical, including stainless steel and high-pressure versions, and MCD is manual. They discharge condensate from dryers, filters, receivers and pipes, with the control type chosen according to the installation. |
Why OMEGA AIR?
- Several drying principles in the same family: refrigeration, heatless adsorption, heated adsorption, hybrid or membrane, so the dew point can be matched to the application
- The A-DRY TAC series has an activated carbon tower after the dryer: useful when the air must also be free of oil vapour
- Condensate drains in four types, from electronic to automatic mechanical: chosen by pressure and by how clean the condensate is
- Filter housings in carbon steel, aluminium and stainless steel, including CHP and IHP for high pressures: covering everything from the factory network to special installations
- The silicone-free AAFs versions and the breathing air filters: meeting the requirements of paint shops and of breathing air
Which OMEGA AIR codes and series are requested most often?
| Code | Description |
|---|---|
| A-DRY | Adsorption dryer, heatless-regenerated, with desiccant |
| A-DRY TAC | A-DRY adsorption dryer with activated carbon tower |
| X-DRY | Modular adsorption dryer, heatless-regenerated |
| HP-DRY | High-pressure adsorption dryer, heatless-regenerated |
| PICO-DRY | Adsorption dryer, heatless-regenerated |
| RDP | Refrigeration dryer with EMD electronic drain |
| RDT | Refrigeration dryer with timed condensate drain |
| RDHP | Refrigeration dryer for high-pressure compressed air |
| AAF | Filter housing for solid particles, water and oil aerosols |
| BF | Welded carbon steel filter housing |
| EMD | Electronic condensate drain |
| AOK | Automatic mechanical condensate drain |
Where is OMEGA AIR equipment used?
- General production and maintenance: air for pneumatic tools, cylinders and factory networks
- Paint shops and finishing: silicone-free filtration and dry air for spraying
- Food and pharmaceutical industry: sterile stainless steel filters and dry air in contact with the process
- Instrumentation and automation: low dew point air for valves and positioners
- Compressors and air stations: drying, filtration and condensate discharge after the compressor
How do we supply OMEGA AIR in Romania?
We can quote adsorption and refrigeration dryers, filters with replacement elements and OMEGA AIR condensate drains. For a correct quotation, send the series or the code from the equipment nameplate, the air flow rate, the working pressure, the inlet air temperature and the required dew point. For drains, the current type (electronic, timed or mechanical) and the maximum pressure help us. The equipment is supplied to order, usually in 1–4 weeks, and spare parts can ship in 24–72 h when the item is in stock, locally or at the supplier. The exact lead time is confirmed in the quotation.
For a replacement dryer or filter, we check in the quotation that it matches the existing series, based on the nameplate and on the flow and pressure data you send.
Frequently asked questions about OMEGA AIR
What equipment does OMEGA AIR make?
OMEGA AIR makes, from Ljubljana, compressed air dryers (refrigeration, adsorption, hybrid, membrane), filters and filter housings, separators and condensate drains, heat exchangers for air cooling and adsorbents. The usual series are A-DRY, RDP, AAF and EMD.
Refrigeration or adsorption dryer, how do I choose?
The refrigeration type, for example RDP, removes water by cooling and reaches a positive dew point, suitable for general networks. The adsorption type, for example A-DRY, goes well below zero and is chosen for instrumentation or paint shops. Send the flow rate, the pressure and the required dew point.
How soon can I receive an OMEGA AIR dryer or filter?
Dryers and filters are ordered and usually arrive in 1–4 weeks. A filter element or a drain can ship in 24–72 h when the item is in stock, locally or at the supplier. For large units or special series the lead time can be longer and appears in the quotation.
Can I replace an EMD or AOK condensate drain with a new part?
Yes, if we identify the type. We need the series on the body (EMD, IED, TD M, AOK or MCD), the maximum pressure in the installation, the connection type and the material, plastic, aluminium or stainless steel. With these data we check the match and prepare the quotation for the correct item.
What data do I send for a quotation on a compressed air dryer?
The series and the code from the nameplate, if you are replacing a unit, or the air flow rate, the working pressure, the inlet temperature, the required dew point and the supply voltage, if you are designing a new one. Also say whether the air comes into contact with food or paint.
How do I request a OMEGA AIR quotation?
Send the OMEGA AIR code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: OMEGA AIR (manufacturer documentation)