Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Pall supplier in Romania

From the Pall range we offer Ultipor III filter elements (for example HC9604 and HC0101), Supor PES membrane filters and oil-water separators; from the full element code we find the exact item or its successor.

Founded in 1946 · Headquarters: Port Washington, New York, USA

Request a quote

Who is Pall and what does it make?

Pall Corporation is a global supplier of filtration, separation and purification technologies. Pall was founded in 1946. Today Pall develops filtration solutions for critical industries: biopharmaceutical, microelectronics, ultra-pure water, food and beverage, aerospace and energy.

Pall offers membranes and filter media for filtration, separation and purification. Supor membranes are made of polyethersulfone (PES), in retention ratings of 0.2 and 0.45 microns, according to the manufacturer's data sheet.

Pall sites hold quality and environmental certifications stated in the manufacturer's documentation. Pall's reliability in critical applications is documented by the manufacturer: uniform batches, full validation and solid technical support.

What do we supply from the Pall range?

ProductDescription
Supor PES membrane filtersAbsolute-rated cartridge with an asymmetric hydrophilic polyethersulfone membrane. Retention ratings are 0.2 μm (HTRA, LTRA) and 0.45 μm (HTRB); validation tests are confirmed from Pall documentation. The double-layer construction provides mechanical strength and integrated prefiltration. Chemical compatibility is checked in the manufacturer's data sheet for each fluid. Steam sterilisation at 125°C (257°F) and hot water sanitisation at 85°C (185°F), according to the manufacturer's data sheet. Applications: sterile filtration of parenteral solutions, vaccines, biological products, sterile culture media, water for injection. Integrity can be tested by bubble point, diffusion or pressure hold test. 316L electropolished housing for sanitary applications. Tri-Clamp, DIN 11851 and ANSI flange connections. Available in 5", 10", 20", 30" and 40" lengths.
Water purification systemsTurnkey water purification installations for microelectronics and pharma. Multi-step process: multimedia prefiltration, activated carbon, softener, double-pass RO, continuous electrodeionisation (CEDI), final 0.2 μm filtration, UV 185/254 nm, recirculation with ultrafiltration. Water quality, capacity and automation depend on the project and are confirmed from Pall documentation. Online monitoring: conductivity, TOC, particles, dissolved ozone. Integrated CIP system for periodic membrane sanitisation. Contact materials: 316L electropolished, PVDF, PVC-U. Design according to ASME BPE for pharmaceutical applications. Energy efficiency - energy recovery through RO pressure turbines. Small footprint - skid-mounted systems ready to connect. Predictive service through membrane parameter monitoring.
Oil-water separatorsEnhanced coalescence technology for separating emulsified oil from industrial water. Principle: prefiltration of large particles, coalescence on a special oleophilic medium, gravity separation in a dedicated chamber, final postfiltration. Efficiency and flow are confirmed in the manufacturer's documentation. Pall's proprietary coalescence medium - 3D structure optimised to capture oil droplets of 5-20 μm. Applications: water from CNC machine tools, refrigeration systems, industrial washing facilities, refinery drains. PP, GRP or coated carbon steel construction. Compact - underground or surface installation. Simple maintenance - coalescence medium replaced every 6-12 months. Mobile versions for temporary sites or emergencies.
Process vent filters for fermentersSterile filters for bioreactor aeration and fermenter vent protection. Hydrophobic PTFE membrane, 0.2 μm absolute - retention of Brevundimonas and other contaminants. 316L sanitary housing, autoclavable at 125°C. Standard Tri-Clamp connections, 1" - 3". Flow and the number of sterilisation cycles are confirmed in the manufacturer's documentation. Applications: sterile aeration of bacteria/yeast/fungi fermenters, protection of media storage tanks, vent breathing protection during transfer. The design ensures condensate does not block the pores - gravity drainage structure. Integrity tests by bubble point. Complete sets available with SS housing, ΔP gauge, isolation valves and connections. Compatible with automation systems - optional pressure transmitter connection. Complete validation documentation for GMP audits. Maintenance: integrity check before each batch, replacement after 6-12 months or 50 sterilisation cycles.

Why Pall?

  • Broad filtration portfolio for critical applications (pharma, semiconductors)
  • Supor polyethersulfone membranes, in retention ratings of 0.2 and 0.45 microns
  • Manufacturer's technical documentation for each product family
  • Ultipor III filter elements for hydraulics and lubrication, with Beta ratios from the manufacturer's technical documentation
  • Technical support and validation for regulated industries

Which Pall codes and series are requested most often?

CodeDescription
HC9604Ultipor III filter element, size series 9604
HC0101Ultipor III filter element, size series 0101
HC2225Ultipor III filter element, size series 2225
HC2253Ultipor III filter element, size series 2253
H9604FKNUYURfull Ultipor III element code, older design (letter K was replaced by R or H in Supralon), Beta 1000 ratio
HC0101FKN18HY533full Ultipor III element code, older design (letter K was replaced by R or H in Supralon), Beta 1000 ratio
HC0101FKZ36Hfull Ultipor III element code, older design (letter K was replaced by R or H in Supralon), Beta 1000 ratio
HC2225FKS19Zfull Ultipor III element code, older design (letter K was replaced by R or H in Supralon), Beta 1000 ratio
HC2253FKS16Hfull Ultipor III element code, older design (letter K was replaced by R or H in Supralon), Beta 1000 ratio
HC2253FKN8Hfull Ultipor III element code, older design (letter K was replaced by R or H in Supralon), Beta 1000 ratio
HTRASupor membrane, fine retention at 0.2 microns
LTRASupor membrane, retention at 0.2 microns
HTRBSupor membrane, retention at 0.45 microns

Where is Pall equipment used?

  • pharma
  • biotech
  • semiconductor
  • food-beverage
  • aerospace
  • automotive
  • oil-gas
  • chemical
  • power-generation
  • municipal-water

How do we supply Pall in Romania?

For Pall filters and systems, availability is checked on each request, and GMP validation of installations is outside our offer. Components can ship in 24–72 h when the item is in stock, locally or at the supplier, while specific cartridges or systems are supplied to order, typically in 1–4 weeks. For a concrete answer, send us the cartridge code or the technical specification of the application (flow, pressure, purity requirements). We confirm real availability after checking, not before.

IQ/OQ/PQ validation and manufacturer-warranty service for Pall systems are outside our offer, and the availability of filter cartridges is confirmed in the quotation, code by code.

Frequently asked questions about Pall

What does the Beta 1000 rating mean for Pall Ultipor III filters?

Beta 1000 shows the retention efficiency of the element: at that ratio, a filter retains 999 out of 1,000 particles of the specified size passing through it, which means an efficiency of about 99.9%. Ultipor III elements have Beta 1000 ratios for several micron thresholds, depending on the type of filter medium chosen.

What is the difference between Supor HTRA and HTRB membranes from Pall?

HTRA is a high-efficiency Supor membrane for retaining fine colloids at 0.2 microns, while LTRA is the standard-efficiency variant for the same 0.2 micron threshold. HTRB is the more permissive 0.45 micron threshold, suitable where very fine filtration is not required. The full cartridge code combines the length, this retention code and the adaptor type.

What does the code HC9600FRP16Z of a Pall Supralon element mean?

The code HC9600FRP16Z reads as follows: HC = Pall hydraulic cartridge; 9600 = product family; F = filter element; R = Supralon medium for standard-collapse elements (H = high collapse); P = 5 µm grade (Z 3, P 5, N 7, S 12, T 25 µm, Betax(c) ≥ 2000); 16 = nominal length of 16 inch; Z = fluorocarbon seals.

What should I send for a quotation on a Pall filter element?

The full code from the existing filter element is useful, as it includes the length, filtration threshold and adaptor type. If you do not have the code, give the dimensions of the filter housing and the type of fluid filtered (water, hydraulic, gas), and we identify the matching Pall variant from the manufacturer's ordering structure.

How do I read the code of an Ultipor III element, for example HC2253FKS16H?

The code HC2253FKS16H is an older Ultipor III design: HC = Pall hydraulic cartridge; 2253 = product family; F = filter element; K = medium type from the older designs, replaced in Supralon by R (standard collapse) or H (high collapse). For the current equivalent, send the full code and we identify it on the Supralon structure.

How do I request a Pall quotation?

Send the Pall code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Pall Corporation, Wikipedia (manufacturer documentation)