Oventrop supplier in Romania
For Oventrop we quote Regumat stations, HydroControl and HydroCom hydronic balancing valves, Cocon Q pressure-independent valves and Regudis W apartment stations; we quote on the catalogue code.
Founded in 1851
Who is Oventrop and what does it make?
Oventrop is a German manufacturer of control technology for heating, cooling and potable water, founded in 1851 and based in Olsberg. The main families are the HydroControl and HydroCom hydronic balancing valves, the Cocon Q and Cocon QTZ pressure-independent valves, the Regumat heating circuit stations, the Regumaq X (central) and Regudis W (apartment) hot water stations, the Regudis H district heating stations, the Regusol solar stations and the Optibal ball valves. For installations in Romania we can quote individual modules or complete stations for a new circuit.
The choice starts from what has to be controlled: on risers and circuits HydroControl or HydroCom are used, and where the flow must stay constant regardless of the other circuits, Cocon Q; QTZ is the version for fan coil units and cooling ceilings. Regumat stations serve heating circuits, including installations with solid-fuel boilers.
The potable water range includes Aquastrom circulation and sampling valves and Regudrain flushing stations, and in the smart building area there are Smart Building solutions, including DynaTemp monitoring.
What do we supply from the Oventrop range?
| Product | Description |
|---|---|
| Regumat Stations | Stations for heating circuits, including for installations with solid-fuel boilers. They are chosen for buildings with several circuits; for sizing, the circuit flow rate, the heating medium temperature and whether mixing is needed all matter. |
| HydroControl and HydroCom | Hydronic balancing valves for adjusting circuits and risers. They are chosen when each circuit must receive its design flow rate; for the quotation, the flow rate of each circuit is required. |
| Cocon Q and Cocon QTZ | Pressure-independent valves that maintain the set flow rate regardless of variations in the rest of the network. QTZ is intended for fan coil units and cooling ceilings. |
| Regudis W, Regumaq X and Regudis H | Domestic hot water stations: Regudis W in the apartment, Regumaq X central for potable hot water, Regudis H for local or district heating. They are chosen according to the number of consumption points and the peak flow rate. |
Why Oventrop?
- HydroControl and HydroCom for hydronic balancing of risers and circuits
- Cocon Q and QTZ, pressure-independent valves; QTZ for fan coil units and cooling ceilings
- Regumat stations for heating circuits, including with solid-fuel boilers
- Domestic hot water stations: Regumaq X central and Regudis W in the apartment
- Range for potable water (Aquastrom, Regudrain) and for solar thermal (Regusol)
Which Oventrop codes and series are requested most often?
| Code | Description |
|---|---|
| Regumat | Station for heating circuits |
| Regudis W | Apartment station for domestic hot water |
| Regudis H | Transfer station for local and district heating |
| HydroControl | Hydronic balancing valve |
| HydroCom | Hydronic balancing valve |
| Cocon Q | Pressure-independent valve for constant flow |
| Cocon QTZ | Pressure-independent valve for fan coil units and cooling ceilings |
| Regumaq X | Central station for potable hot water |
| Aquastrom | Circulation and sampling valves, for potable water hygiene |
| Optibal | Shut-off ball valves; Optibal W6 is the control version |
| Regudrain | Flushing station for potable water networks |
| Flypass | Multifunctional connection set for heating and cooling units |
| Regusol | Station for solar thermal installations |
Where is Oventrop equipment used?
- Multi-storey residential buildings — hydronic balancing on circuits and apartments
- Commercial HVAC — balancing and control on heating and cooling circuits
- Domestic hot water production — central and apartment stations
- Solar thermal energy — Regusol stations
- Smart buildings — control and monitoring
How do we supply Oventrop in Romania?
The quotation is prepared from Oventrop technical documentation, by catalogue code or family. We need the design flow rate of each circuit, the heating medium temperature and the connection type (threaded or flanged). To order, usually 1–4 weeks, depending on the range chosen and the connection; we confirm the exact lead time in the quotation.
Software configuration of Smart Building systems is carried out by the installation integrator; we select and quote the valves and stations suited to the circuit.
Frequently asked questions about Oventrop
How do I choose between HydroControl, HydroCom and Cocon Q for the same circuit?
HydroControl and HydroCom are balancing valves that are adjusted manually; Cocon Q is pressure-independent and maintains its flow rate by itself when the other circuits close or open. For the choice, the design flow rate and the available pressure are required.
Which Oventrop family do I choose for hot water in an apartment block?
Regudis W produces hot water at the apartment, Regumaq X produces it centrally, and Regudis H connects the building to local or district heating. For a quotation, the number of consumption points and the peak flow rate are required.
How can I request an Oventrop valve or station if I only have the family name?
Send us the family (Regumat, Cocon, Optibal etc.), the nominal diameter, the connection type and the flow rate; we establish the article code from the catalogue and confirm it in the quotation.
How long does it take to receive an Oventrop valve or station?
To order, usually 1–4 weeks, depending on the model and availability.
How do I request a Oventrop quotation?
Send the Oventrop code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 20 November 2026 · Sources: Oventrop (manufacturer documentation)