PEAK-System Technik supplier in Romania
For PEAK-System Technik we quote PCAN-USB FD, Pro FD and X6 interfaces, PCAN-PCI Express FD cards, PCAN-MicroMod FD modules and PCAN-Router Pro FD routers, starting from the number of channels and the bus type.
Headquarters: Darmstadt, Germany
Who is PEAK-System Technik and what does it make?
PEAK-System Technik is a German manufacturer based in Darmstadt, specialising in interfaces, converters and modules for CAN, CAN FD and LIN buses. The range includes PC interfaces with USB and with internal cards (PCAN-USB, PCAN-PCI Express FD, PCAN-miniPCIe FD, PCAN-M.2), PCAN-MicroMod FD input-output modules, PCAN-Router routers and gateways, optical converters and repeaters, PCAN-Diag diagnostic devices and analysis software such as PCAN-View and PCAN-Explorer, with the PCAN-Basic programming interface.
CAN FD (CAN with flexible data rate) transmits up to 64 bytes per frame, at rates of up to 12 Mbit/s, and remains compatible with CAN 2.0 A/B. The PCAN-USB FD connects a CAN or CAN FD network over USB, with galvanic isolation of up to 500 V. The PCAN-USB Pro FD has two CAN FD channels and two LIN channels, each channel separately isolated. The PCAN-USB X6 connects up to six CAN FD buses, with versions with D-Sub or M12 connectors for harsh environments and isolation of up to 300 V. The PCAN-PCI Express FD card is available with one, two or four channels. The interfaces support both versions of the protocol, ISO and non-ISO, selectable from software.
The devices appear on test benches and hardware-in-the-loop simulation (with the real equipment connected in the loop), in end-of-line product testing, and in bus monitoring on mobile machinery and in automation. The quotation starts from the number of channels, the bus type (CAN, CAN FD or LIN), the isolation, the format (external or card), the connector and the operating system.
What do we supply from the PEAK-System Technik range?
| Product | Description |
|---|---|
| PCAN-USB, FD, Pro FD and X6 USB interfaces | CAN FD interfaces over USB: PCAN-USB FD for one bus, with USB-A or USB-C and 500 V isolation; PCAN-USB Pro FD with 2 × CAN FD and 2 × LIN; PCAN-USB X6 with six channels, aluminium housing and an M12 version. |
| PCAN-PCI Express FD, miniPCIe FD and M.2 internal cards | Cards for industrial computers: PCAN-PCI Express FD with one, two or four CAN FD channels and 500 V isolation, plus miniPCIe, M.2, PC/104-Plus and PCI/104-Express versions for embedded systems. |
| Input-output modules and routers | PCAN-MicroMod FD with analogue, digital and CANopen versions, PCAN-MIO, the MU-Thermocouple1 CAN FD module, PCAN-Router Pro FD routers with data logging and Ethernet-CAN gateways for linking networks. |
| Software, diagnostics and converters | PCAN-View and PCAN-Explorer 7 for analysis, PCAN-Basic for programming, PCAN-Diag FD and MiniDiag FD devices, plus optical converters and repeaters (PCAN-Optoadapter, PCAN-Repeater, PCAN-LWL) for isolation and extension. |
Why PEAK-System Technik?
- USB interfaces for CAN FD — PCAN-USB FD, Pro FD, X6 and XL, with 300–500 V galvanic isolation between the computer and the bus
- Multiple channels — PCAN-USB X6 with up to six CAN FD buses, PCAN-USB Pro FD with 2 × CAN FD and 2 × LIN, PCI Express FD with up to four channels
- Connectors for harsh environments — M12 version on the PCAN-USB X6 and modules with an aluminium profile housing
- CAN FD ISO and non-ISO — both versions of the protocol, selectable from software, with speeds of up to 12 Mbit/s
- Software and API included — PCAN-View for monitoring and PCAN-Basic for programming, with PCAN interfaces
Which PEAK-System Technik codes and series are requested most often?
| Code | Description |
|---|---|
| PCAN-USB | CAN interface over USB, one bus |
| PCAN-USB FD | CAN FD interface over USB, 500 V isolation |
| PCAN-USB Pro FD | USB interface with 2 × CAN FD and 2 × LIN |
| PCAN-USB X6 | USB interface with six CAN FD channels, M12 version |
| PCAN-USB XL | USB interface from the PCAN range |
| PLIN-USB | LIN interface over USB |
| PCAN-PCI Express FD | PCIe CAN FD card with 1, 2 or 4 channels |
| PCAN-miniPCIe FD | miniPCIe card with CAN FD channels |
| PCAN-M.2 | M.2 card for CAN buses |
| PCAN-MicroMod FD | Input-output module with CAN FD |
| PCAN-MIO | Input-output module for CAN |
| MU-Thermocouple1 CAN FD | Thermocouple temperature measurement module, CAN FD |
| PCAN-Router Pro FD | CAN FD router with data logging |
| PCAN-Diag FD | Diagnostic device for CAN FD buses |
| PCAN-View | CAN bus monitoring program |
| PCAN-Basic | Programming interface for CAN applications |
Where is PEAK-System Technik equipment used?
- Test benches and hardware-in-the-loop simulation — PCAN-USB X6 interfaces with several buses
- End-of-line production testing — multichannel interfaces and input-output modules
- Mobile and agricultural machinery — CAN monitoring and data logging with PCAN-Router Pro FD
- Industrial automation — gateways, routers and input-output modules for CAN and CANopen
- Laboratory and development equipment — USB interfaces with galvanic isolation and API libraries
How do we supply PEAK-System Technik in Romania?
From the PEAK-System range we can quote PCAN-USB interfaces, PCAN-PCI Express FD cards, PCAN-MicroMod FD modules, PCAN-Router routers, gateways, optical converters, cables and adapters. Interfaces are supplied to order, usually in 1–4 weeks; for special configurations, depending on the specification, the lead time may be longer. For a quotation, send the number of channels and the bus type (CAN, CAN FD, LIN), the format (USB or card), the desired isolation, the connector (D-Sub or M12), the operating system and, for a replacement, the code on the label.
Software application development and configuration of the customer's CAN network are outside our offer.
Frequently asked questions about PEAK-System Technik
What does PEAK-System Technik make?
PEAK-System makes interfaces, modules, routers and software for CAN, CAN FD and LIN buses: PCAN-USB, PCI Express and M.2 cards, PCAN-MicroMod FD modules, PCAN-Router routers, PCAN-Diag devices and analysis programs. The company is based in Darmstadt, Germany.
How do I choose between PCAN-USB FD, Pro FD and X6?
The PCAN-USB FD serves one CAN or CAN FD bus. The Pro FD adds two LIN channels to its two CAN FD channels, and the X6 connects up to six buses, with an M12 version for harsh environments. Send the number of buses, the type and the required isolation so that we can check the model.
Do you supply PEAK interfaces in Romania and how quickly?
Yes. They can ship in 24–72 h when the item is in stock, locally or at the supplier; interfaces are usually supplied to order, in 1–4 weeks. Depending on the specification, the lead time may be longer for configurations with special transceivers; we confirm it in the quotation.
Can I replace an old PCAN interface with one from the FD series?
The FD interfaces support CAN 2.0 A/B and CAN FD, and full compatibility with the current application and driver is confirmed after checking. Send the code of the old interface, the operating system and the application used, and we check the suitable model before the quotation.
What data do I need to send for a quotation on a PCAN-PCI Express FD card?
We need the number of channels (1, 2 or 4), the slot type in the computer, the operating system, the desired isolation, the transceiver type and the connector. If you use it in an industrial computer, also send its model, so that the card profile can be checked.
How do I request a PEAK-System Technik quotation?
Send the PEAK-System Technik code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: PEAK-System Technik GmbH (manufacturer documentation)