VX is the Pedrollo series of submersible pumps with VORTEX impeller, used especially in automated fixed installations. It exists in a single-phase version (VXm, 230 V – 50 Hz, with thermal protection integrated in the winding) and a three-phase version (VX, 400 V – 50 Hz), in four P2 powers (0.55; 0.75; 1.1 and 1.5 kW) and in two designs: /35, with a 1½" connection and a solids passage of Ø 40 mm, and /50, with a 2" connection and a passage of Ø 50 mm. They are used in buildings and in industry, for groundwater, surface water and wastewater, emptying flooded areas (basements, underground car parks, car washes) and emptying the septic tank and sewer networks. The pump body is cast iron, the impeller and the motor jacket are AISI 304 stainless steel, and the sealing is double, in an oil bath.

For a quotation, please send us the full code from the pump nameplate (for example VXm 10/35 or VX 15/50), the mains voltage and frequency, the supply cable length required, the type of liquid pumped, the maximum solids size, and the flow and head required. When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.

Models and codes

CodeNote
VXm 8/35 / VX 8/35VXm 8/35 (single-phase, 230 V, 4.3 A, 13.7 kg) and VX 8/35 (three-phase, 400 V, 1.6 A, 12.6 kg); P2 0.55 kW (0.75 HP), 1½" connection, solids passage Ø 40 mm, head 9 m at flow 0, dimension h from the dimension table 425 mm, minimum immersion for continuous duty 290 mm.
VXm 10/35 / VX 10/35VXm 10/35 (single-phase, 230 V, 5.5 A, 15.2 kg) and VX 10/35 (three-phase, 400 V, 2.2 A, 14.0 kg); P2 0.75 kW (1 HP), 1½" connection, solids passage Ø 40 mm, head 11 m at flow 0, dimension h from the dimension table 440 mm, minimum immersion for continuous duty 290 mm.
VXm 15/35 / VX 15/35VXm 15/35 (single-phase, 230 V, 7.0 A, 18.0 kg) and VX 15/35 (three-phase, 400 V, 2.7 A, 16.4 kg); P2 1.1 kW (1.5 HP), 1½" connection, solids passage Ø 40 mm, head 14 m at flow 0, dimension h from the dimension table 473 mm, minimum immersion for continuous duty 330 mm.
VXm 20/35 / VX 20/35VXm 20/35 (single-phase, 230 V, 9.6 A, 20.2 kg) and VX 20/35 (three-phase, 400 V, 3.7 A, 18.0 kg); P2 1.5 kW (2 HP), 1½" connection, solids passage Ø 40 mm, head 15.5 m at flow 0, dimension h from the dimension table 503 mm, minimum immersion for continuous duty 360 mm.
VXm 8/50 / VX 8/50VXm 8/50 (single-phase, 230 V, 4.3 A, 14.2 kg) and VX 8/50 (three-phase, 400 V, 1.6 A, 13.1 kg); P2 0.55 kW (0.75 HP), 2" connection, solids passage Ø 50 mm, head 6.5 m at flow 0, dimension h from the dimension table 436 mm, minimum immersion for continuous duty 290 mm.
VXm 10/50 / VX 10/50VXm 10/50 (single-phase, 230 V, 5.5 A, 15.7 kg) and VX 10/50 (three-phase, 400 V, 2.2 A, 14.5 kg); P2 0.75 kW (1 HP), 2" connection, solids passage Ø 50 mm, head 9 m at flow 0, dimension h from the dimension table 451 mm, minimum immersion for continuous duty 290 mm.
VXm 15/50 / VX 15/50VXm 15/50 (single-phase, 230 V, 7.0 A, 18.5 kg) and VX 15/50 (three-phase, 400 V, 2.7 A, 16.9 kg); P2 1.1 kW (1.5 HP), 2" connection, solids passage Ø 50 mm, head 11.5 m at flow 0, dimension h from the dimension table 484 mm, minimum immersion for continuous duty 330 mm.
VXm 20/50 / VX 20/50VXm 20/50 (single-phase, 230 V, 9.6 A, 20.7 kg) and VX 20/50 (three-phase, 400 V, 3.7 A, 18.5 kg); P2 1.5 kW (2 HP), 2" connection, solids passage Ø 50 mm, head 13.5 m at flow 0, dimension h from the dimension table 514 mm, minimum immersion for continuous duty 360 mm.

Key specifications

Flowup to 750 (45 m³/h) l/min
Headup to 15.5 m
Power P2 / supply0.55–1.5 kW (0.75–2 HP); VXm single-phase 230 V – 50 Hz, VX three-phase 400 V – 50 Hz
Absorbed currentVXm 230 V: 4.3–9.6 A; VX 400 V: 1.6–3.7 A (depending on power)
Suspended solidsup to Ø 40 mm for VX /35 and up to Ø 50 mm for VX /50
Discharge connection1½" for VX /35; 2" for VX /50
Liquid temperatureup to +40 °C
Depth below water levelup to 5 m (with a suitably sized supply cable)
Materialsbody in cast iron with cataphoresis treatment; VORTEX impeller, base and motor jacket in AISI 304 stainless steel; shaft in AISI 431 stainless steel; double mechanical seal in an oil bath (motor side: silicon carbide / graphite / NBR; pump side: silicon carbide / silicon carbide / NBR); motor insulation class F, protection rating IP X8

The VX series appears with its own page in the current range of submersible pumps for wastewater and drainage on the official Pedrollo website, with no withdrawal notice; the 50 Hz datasheet “VX – Submersible pumps VORTEX” (4 pages, English version) is published on the series page, together with the 60 Hz datasheet and the installation and use manuals.

Frequently asked questions

What is the difference between VXm and VX?

VXm is the single-phase version (230 V – 50 Hz), with capacitor, thermal protection integrated in the winding, cable with Schuko plug and float switch; VX is the three-phase version (400 V – 50 Hz); the float, the capacitor and the Schuko plug are included only on the single-phase models. The P2 powers are the same (0.55–1.5 kW). In the quotation we confirm the version from the voltage on the nameplate.

How do I choose between the /35 and /50 designs?

The /35 design has a 1½" connection and lets solids of up to Ø 40 mm pass, while /50 has a 2" connection and a passage of up to Ø 50 mm. The maximum flow stated in the datasheet is 750 l/min (45 m³/h), reached in the /50 range; for each model the head decreases as the flow increases, following the curves in the datasheet.

What data should I send for a replacement VX pump?

The full code from the nameplate (for example VXm 15/35), the voltage and frequency, the cable length and, if available, the minimum water level in the sump: the datasheet requires a minimum immersion of 290 mm (VX 8 and VX 10), 330 mm (VX 15) or 360 mm (VX 20) for continuous duty. We check the combination in the Pedrollo documentation before the quotation.

Other Pedrollo series

We confirm for the exact code the voltage, the /35 or /50 design, the cable length and the limits of use in the Pedrollo documentation before the quotation; the values from the curves are given with the tolerances of EN ISO 9906 grade 3B, and for operation at 60 Hz we use the dedicated datasheet.

Updated: 2026-11-23