Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Pedrollo Pedrollo VXC / VXCm (VXC-F)

Pedrollo VXC (three-phase, 400 V) and VXCm (single-phase, 230 V) /50 and /65 submersible pumps, with VORTEX impeller, in threaded and flanged (-F) designs, for wastewater with suspended solids of up to Ø 50 mm (/50) or Ø 65 mm (/65), flow up to 1,250 l/min (75 m³/h) for /65, head up to 20 m, liquid up to +40 °C.

VXC is the Pedrollo series of submersible pumps with a VORTEX-type impeller, built, according to the datasheet, from thick cast iron, for abrasion resistance. The series has the /50 design (2½" connection, solids passage of Ø 50 mm) and the /65 design (3" connection, passage of Ø 65 mm), in two forms: VXC with threaded connection and VXC-F with a flange at the discharge. VXCm is the single-phase version (230 V – 50 Hz, with motor thermal protection), and VXC is the three-phase version (400 V – 50 Hz); the P2 powers are 1.1; 1.5; 2.2 and 3 kW, and the 3 kW models (VXC 40/50 and VXC 40/65, with the -F variants) are listed in the datasheets only in the three-phase version. The datasheet describes them for wastewater, water mixed with sludge, activated and digested sludge, in applications such as sewers, tunnels, excavations, canals and underground car parks (VXC) or special wells and sumps (VXC-F). On the Pedrollo website, VXC /35 and /45 and VXC4 (4-pole) have separate pages and datasheets and are not covered here.

For a quotation, please send us the full code from the pump nameplate (for example VXC 40/50 or VXCm 20/65-F), the mains voltage and frequency, the supply cable length required, the type of liquid pumped, the maximum solids size, and the flow and head required. When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.

Models and codes

CodeNote
VXCm 15/50 / VXC 15/50VXCm 15/50 (single-phase, 230 V, 8.5 A, 42.1 kg) and VXC 15/50 (three-phase, 400 V, 3.4 A, 40.0 kg); P2 1.1 kW (1.5 HP), solids passage Ø 50 mm, head 12 m at flow 0.
VXCm 30/50 / VXC 30/50VXCm 30/50 (single-phase, 230 V, 12.0 A, 48.0 kg) and VXC 30/50 (three-phase, 400 V, 5.0 A, 44.0 kg); P2 2.2 kW (3 HP), solids passage Ø 50 mm, head 16.5 m at flow 0.
VXC 40/50VXC 40/50 (listed only three-phase, 400 V, 6.2 A, 48.0 kg); P2 3 kW (4 HP), solids passage Ø 50 mm, head 20 m at flow 0.
VXCm 20/65 / VXC 20/65VXCm 20/65 (single-phase, 230 V, 9.0 A, 45.1 kg) and VXC 20/65 (three-phase, 400 V, 3.7 A, 44.0 kg); P2 1.5 kW (2 HP), solids passage Ø 65 mm, head 9.5 m at flow 0.
VXC 40/65VXC 40/65 (listed only three-phase, 400 V, 6.2 A, 49.8 kg); P2 3 kW (4 HP), solids passage Ø 65 mm, head 15.5 m at flow 0.
VXCm 15/50-F / VXC 15/50-FVXCm 15/50-F (single-phase, 230 V, 8.5 A, 43.6 kg) and VXC 15/50-F (three-phase, 400 V, 3.4 A, 42.0 kg); P2 1.1 kW (1.5 HP), solids passage Ø 50 mm, head 12 m at flow 0, flange DN 65 (PN 10).
VXC 40/50-FVXC 40/50-F (listed only three-phase, 400 V, 6.2 A, 50.0 kg); P2 3 kW (4 HP), solids passage Ø 50 mm, head 20 m at flow 0, flange DN 65 (PN 10).
VXCm 20/65-F / VXC 20/65-FVXCm 20/65-F (single-phase, 230 V, 9.0 A, 47.1 kg) and VXC 20/65-F (three-phase, 400 V, 3.7 A, 46.0 kg); P2 1.5 kW (2 HP), solids passage Ø 65 mm, head 9.5 m at flow 0, flange DN 80 (PN 10).

Key specifications

Flowup to 1,250 l/min (75 m³/h) for VXC /65 and /65-F; the VXC /50 and /50-F tables end at 1,050 l/min (63 m³/h)
Headup to 20 m (VXC 40/50 and 40/50-F); at flow 0: 12–20 m for /50 and 8–15.5 m for /65 (the same for the -F designs)
Power P2 / supply1.1–3 kW (1.5–4 HP); VXCm single-phase 230 V – 50 Hz, VXC three-phase 400 V – 50 Hz; 3 kW models three-phase only
Absorbed currentVXCm 230 V: 8.5–12 A; VXC 400 V: 3.4–6.2 A (depending on power; the same values for /50, /65 and the -F designs)
Suspended solidsup to Ø 50 mm for /50 and /50-F; up to Ø 65 mm for /65 and /65-F
Discharge connection2½" for /50 and 3" for /65 (VXC); for VXC-F, flange DN 65 (PN 10) for /50-F and DN 80 (PN 10) for /65-F
Liquid temperature and depthliquid up to +40 °C; depth below water level up to 10 m (with a suitably sized supply cable); continuous operation of the pump even when completely uncovered
MassVXC: 42.1–49.8 kg single-phase and 40.0–49.8 kg three-phase; VXC-F: 43.6–51.8 kg single-phase and 42.0–51.8 kg three-phase (depending on model)
Materialsbody, VORTEX impeller, motor support and motor bracket in cast iron with cataphoresis treatment; shaft in AISI 431 stainless steel; double mechanical seal with oil chamber; 2-pole motor, insulation class F, protection rating IP X8

The VXC 50-65 and VXC-F series appear with their own pages in the current range of submersible pumps for wastewater and drainage on the official Pedrollo website, with no withdrawal notice; the 50 Hz datasheets “VXC – Submersible pumps VORTEX” (4 pages) and “VXC-F – Flanged submersible pumps VORTEX” (6 pages), in English, are published on the series pages, together with the 60 Hz datasheets and the installation and use manuals.

Frequently asked questions

What do “m” and “-F” mean in the pump code?

In the datasheets, VXCm is the single-phase version (230 V – 50 Hz), and VXC is the three-phase version (400 V – 50 Hz). VXC-F is the “Flanged submersible pumps” series, with a flange at the discharge: DN 65 (PN 10) for /50-F and DN 80 (PN 10) for /65-F, compared with the threaded connection of 2½" and 3" for VXC /50 and /65. The 3 kW models (40/50 and 40/65) are listed only in the three-phase version.

What is the difference between VXC and VX in the Pedrollo datasheets?

According to the 50 Hz datasheets, VX has P2 of 0.55–1.5 kW, a passage of Ø 40 or Ø 50 mm, flow up to 750 l/min, head up to 15.5 m, depth below water up to 5 m and a 5 or 10 m cable, and the VORTEX impeller is AISI 304 stainless steel. VXC /50 and /65 have P2 of 1.1–3 kW, a passage of Ø 50 or Ø 65 mm, flow up to 1,250 l/min, head up to 20 m, depth up to 10 m, a 10 m cable and a cast iron VORTEX impeller, with continuous operation even when completely uncovered. The choice is made on the code from the nameplate.

What data should I send for a replacement VXC pump?

The full code from the nameplate (for example VXC 15/50-F or VXCm 20/65-F), the voltage and frequency, the cable length and the connection form (threaded or flanged). For three-phase models, the datasheet makes the warranty conditional on connecting the motor thermal protector to the control panel. We check the combination in the Pedrollo documentation before the quotation.

Other Pedrollo series

We confirm for the exact code the voltage, the /50 or /65 design, the connection form (threaded or -F), the cable length and the limits of use in the Pedrollo documentation before the quotation; the values from the curves are given with the tolerances of EN ISO 9906 grade 3B, and for operation at 60 Hz we use the dedicated datasheets.

Updated: 2026-11-23