Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

R&D Dynamics Corporation supplier in Romania

Oil-free turbomachinery on foil bearings: expanders, alternators, blowers

Founded in 1990 · Headquarters: Bloomfield, Connecticut, USA

Request a quote

Who is R&D Dynamics Corporation and what does it make?

R&D Dynamics Corporation is an American company founded in 1990, headquartered in Bloomfield, Connecticut, specialised in oil-free turbomachinery supported on air or gas foil bearings. The technology comes from the aerospace industry, where high-speed rotating machines on such bearings were developed, and it has been extended to industrial and commercial machines. In a foil bearing, the shaft, lifted by a self-generated film of air or gas, floats without metal contact: two radial foil bearings take the radial load and two thrust bearings take the axial load. With no lubrication system, the machine has no risk of oil contamination of the process gas.

The product line covers TurboEx turboexpanders, from 1 to 400 kW, used in air separation, in oil and gas extraction and in cryogenic refrigeration (including cryogenic helium expanders and a nitrogen expander for landfill gas recovery); turboalternators from under 5 kW to 400 kW, which convert the energy of a process gas into electrical energy; and motor driven blowers or compressors, from 100 W to over 100 kW, for a temperature range from cryogenic to about 870 °C (1600 °F). Based on a turboalternator with foil bearings, the company also builds the 170 kW AdvancedPower ORC system, for recovering waste heat from the exhaust gases of turbines, diesel engines or furnaces.

These solutions are used in natural gas pressure reduction stations, in cryogenic and air separation installations or in cogeneration with vapour cycles. For a correct quotation, send us the process gas, the flow rate, the inlet and outlet pressures and temperatures and the power required.

What do we supply from the R&D Dynamics Corporation range?

ProductDescription
Air and gas foil bearingsSelf-generated hydrodynamic bearings, in which flexible foils adapt to the shaft. The top foil, supported on corrugated foils that give a small preload, is coated with solid lubricant for low-friction starting and stopping.
TurboEx turboexpandersOil-free turboexpanders, from 1 to 400 kW, with foil bearings. They are used in air separation, in oil and gas exploration and in cryogenic refrigeration systems; versions for cryogenic helium also exist.
TurboalternatorsHigh-speed machines with foil bearings, from under 5 kW to 400 kW, which convert the energy stored in a process gas into electrical energy, for example from waste heat.
Blowers, compressors and AdvancedPower ORCMotor driven blowers and compressors from 100 W to over 100 kW, plus the 170 kW AdvancedPower ORC system for producing electricity from waste heat from gas turbines, diesel engines or furnaces.

Why R&D Dynamics Corporation?

  • Oil-free operation — the process gas stays clean, and the installation has no lubrication circuit to maintain
  • Self-generated foil bearings — two radial and two thrust bearings support the rotor on a film of air or gas, at high speeds
  • TurboEx from 1 to 400 kW — the same turboexpander design for air separation, cryogenics and natural gas
  • Turboalternators from under 5 kW to 400 kW — conversion of the energy of a process gas into electricity, including from waste heat
  • Blowers and compressors from 100 W to over 100 kW — temperature range from cryogenic to about 870 °C

Which R&D Dynamics Corporation codes and series are requested most often?

CodeDescription
TurboExOil-free turboexpander with foil bearings, 1–400 kW
Cryogenic helium turboexpanderTurboexpander for cryogenic helium
Nitrogen turboexpanderNitrogen expander for landfill gas recovery
TurboalternatorHigh-speed turboalternator, under 5 kW up to 400 kW
TurbocompressorOil-free turbocompressor on foil bearings
Motor driven blowerMotor driven blower, 100 W–100 kW
Motor driven compressorMotor driven compressor, up to over 100 kW
AdvancedPower 170 kW ORC170 kW ORC system with turboalternator
Premier TurboTurbo blower for wastewater treatment plants
Foil journal bearingRadial air or gas foil bearing
Foil thrust bearingThrust air or gas foil bearing

Where is R&D Dynamics Corporation equipment used?

  • Natural gas distribution — turboexpanders and turboalternators at pressure reduction stations
  • Cryogenic installations — expanders for helium and nitrogen and for air separation
  • Waste heat recovery — organic Rankine cycles with a turboalternator
  • Wastewater treatment — oil-free turbo blowers for aeration
  • Aeronautics — parts for air cycle machines

How do we supply R&D Dynamics Corporation in Romania?

We can submit your request for turboexpanders, turboalternators, blowers with foil bearings and ORC systems from the R&D Dynamics range. As these are machines designed to a specification, the lead time is set at quotation and can be longer, depending on the specification; spare parts can be supplied to order, usually in 1–4 weeks. Supplied to order. For a correct quotation, tell us the process gas, the mass flow rate, the pressure and temperature at inlet and outlet, the speed wanted, the power and the installation conditions. The exact lead time is confirmed in the quotation.

The quotation starts from the process data, not from a standard machine: each turbomachine is sized by the manufacturer on these data, and performance is confirmed only through the manufacturer's calculation.

Frequently asked questions about R&D Dynamics Corporation

What does R&D Dynamics Corporation make?

R&D Dynamics, of Bloomfield (Connecticut), founded in 1990, makes oil-free turbomachinery on air or gas foil bearings: TurboEx turboexpanders of 1–400 kW, turboalternators, turbocompressors, motor driven blowers and compressors and 170 kW AdvancedPower ORC systems.

How is a turboexpander or a turboalternator sized?

Starting from the process gas, the flow rate, the inlet pressure and temperature, the outlet pressure and the power wanted. The TurboEx range goes from 1 to 400 kW, and the turboalternators from under 5 kW to 400 kW. Send us these data; the sizing is done by the manufacturer, and the version is confirmed in the quotation.

Can you supply R&D Dynamics equipment in Romania and within what lead time?

Yes; these machines are supplied to order. The machines are designed to a specification, so the lead time can be longer and is confirmed in the quotation, depending on the specification; accessories can be supplied to order, usually in 1–4 weeks.

Can I replace an oil-lubricated bearing of my machine with a foil one?

For high-speed turbomachinery, foil bearings are an oil-free alternative, but replacement requires an analysis of the rotor and of the loads. It is confirmed only on the basis of data: send us the machine type, the speed, the rotor mass and the loads, so that the manufacturer can assess the feasibility.

What do I need to send for a quotation on a 170 kW ORC system?

The heat source (exhaust gases from a turbine or engine, furnace), the flow rate and temperature of the gases, the cooling temperature available and the installation site. On this basis we check whether the 170 kW AdvancedPower fits or what configuration it requires.

How do I request a R&D Dynamics Corporation quotation?

Send the R&D Dynamics Corporation code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: R&D Dynamics Corporation (manufacturer documentation)