Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Resonon supplier in Romania

Pika UV, VNIR, IR and SWIR hyperspectral cameras, plus optical sorting systems

Headquarters: Bozeman, USA

Request a quote

Who is Resonon and what does it make?

Resonon is a company from Bozeman, in the American state of Montana, which builds hyperspectral cameras and the systems around them. A hyperspectral camera does not record three colours, like an ordinary one, but a full spectrum for each point of the image, across hundreds of bands. The result is a data cube in which materials that look identical in visible light can be told apart by their spectral signature: types of plastic or various impurities.

The Pika camera range is split by spectral range. Pika UV covers 330–800 nm, Pika L and Pika XC2 cover 400–1000 nm, and Pika L-F, intended for industrial vision, reaches 585 frames per second in the 420–980 nm range. For the near infrared there are Pika IR and Pika IR+ (900–1700 nm), Pika IR-L and IR-L+ (925–1700 nm), and Pika SWIR runs between 1000 and 2500 nm. The Spectronon software is used for acquisition and analysis, and for industrial lines there is the Real-time Vision System (RVS), with three levels: Acquire, Analyze and Automate.

The industrial interest is in optical sorting and classification: plastics recycling, quality control in the food industry, pharmaceutical inspection. The SpectralSight laboratory system allows a feasibility study on samples before an industrial installation. The choice of camera starts from the spectral range needed, the belt speed, the size of the objects and the spatial resolution required.

What do we supply from the Resonon range?

ProductDescription
Pika L and Pika L-FCompact VNIR hyperspectral cameras. Pika L scans 400–1000 nm and is frequently used in remote sensing, and Pika L-F (420–980 nm) reaches 585 frames per second for industrial vision applications.
Pika IR, IR+, IR-L, IR-L+Hyperspectral cameras for the near infrared, between 900 and 1700 nm (IR, IR+) or 925 and 1700 nm (IR-L, IR-L+). The L versions are lightweight, and the plus versions offer higher resolution or precision.
Pika SWIRSWIR hyperspectral imager with high spatial and spectral resolution, between 1000 and 2500 nm. Used for mineral exploration, pharmaceutical inspection, soil characterisation and recycling.
SpectralSight and RVSAutomatic hyperspectral scanning system for laboratory and production, compatible with Pika L, L-F, IR, IR+, IR-L and IR-L+ (400–1700 nm), with RVS software for optical sorting.

Why Resonon?

  • Spectral coverage from ultraviolet to SWIR — Pika cameras run from 330 nm to 2500 nm, in models dedicated to each range
  • Pika L-F for industrial vision — 585 frames per second in the 420–980 nm range, designed for belts and sorting
  • RVS in three levels — object detection and data cube creation, then classification by machine learning, then output to robots or air jets
  • SpectralSight feasibility system — the same workflow on the bench, in the laboratory or in industrial tests, before a complete installation
  • Spectronon software for acquisition and analysis — a single environment for the cameras in the range, from research to field applications

Which Resonon codes and series are requested most often?

CodeDescription
Pika UVUV hyperspectral camera, 330–800 nm
Pika LVNIR hyperspectral camera, 400–1000 nm
Pika L-FFast VNIR camera, 420–980 nm, 585 frames/s
Pika XC2High-precision VNIR camera, 400–1000 nm
Pika IRHyperspectral camera, 900–1700 nm
Pika IR+High-resolution version, 900–1700 nm
Pika IR-LLightweight version, 925–1700 nm
Pika IR-L+Lightweight precision version, 925–1700 nm
Pika SWIRSWIR hyperspectral camera, 1000–2500 nm
SpectralSightAutomatic scanning system for laboratory and production
RVS Acquire / Analyze / AutomateThree levels of the Real-time Vision System software
SpectrononHyperspectral acquisition and analysis software

Where is Resonon equipment used?

  • Recycling — classifying plastics on a belt by spectral signature
  • Food industry — sorting and grading with RVS on production lines
  • Pharmaceutical — SWIR inspection of materials and products
  • Research and remote sensing — Pika L and Pika XC2 cameras in airborne and field systems
  • Mining and geology — mineral exploration in the SWIR range

How do we supply Resonon in Romania?

We can quote Resonon hyperspectral cameras from the Pika family and SpectralSight systems, supplied to order. As these are configured equipment, the lead time can be longer, depending on the specification, and is set in the quotation. For a correct request we need the spectral range wanted (VNIR, 900–1700 nm or SWIR), the type of application, the belt or platform speed, the size of the objects and whether analysis software or additional lenses are needed. For an industrial project, also describe in the request the working distance and the available lighting.

Whether a specific material classification works in your installation is established by trials, before configuration.

Frequently asked questions about Resonon

What does Resonon make?

Resonon, from Bozeman, Montana, makes hyperspectral cameras from the Pika family, between 330 and 2500 nm, systems for laboratory, field and aircraft, as well as analysis software. In industry they are used for optical sorting, material classification and quality control.

How do I choose the spectral range of a Pika camera?

The VNIR models (Pika L, L-F, XC2) work between 400 and 1000 nm, the IR series between 900 and 1700 nm, and Pika SWIR between 1000 and 2500 nm, with applications such as minerals, pharmaceuticals or recycling. Send us the material to be examined and the belt speed.

How quickly do you supply Resonon equipment in Romania?

The equipment is supplied to order. The lead time to order is usually 1–4 weeks, but configured systems, with lenses and software, may need longer; we confirm it after you tell us the spectral range and accessories.

Can I use the same Pika camera on a belt and in the laboratory?

The Pika L, L-F, IR cameras and their variants can be mounted on the SpectralSight system, which works both in the laboratory and in an industrial environment. To confirm a specific configuration, send us the camera model and the scanning speed wanted.

What details should I give for a hyperspectral camera quotation?

The spectral range wanted, the spatial resolution, the scanning speed or rate, the working distance, the lens type, whether you will work on a belt, in the laboratory or on a mobile platform and whether you also need classification software. For a replacement, mention the existing model.

How do I request a Resonon quotation?

Send the Resonon code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: Resonon Inc. (manufacturer documentation)