Sensitron supplier in Romania
For Sensitron we quote fixed gas detectors from the SMART 3G, SMART S and SMART 3 series, PL4+, MULTISCAN 8+ and MULTISCAN++ control units and the PK system for car parks; we need the gas, measuring range, ATEX zone and interface.
Headquarters: Cornaredo, Italy
Who is Sensitron and what does it make?
Sensitron, based in Cornaredo, near Milan, in Italy, makes gas detection systems: fixed detectors, control units and systems for special applications. The detectors measure flammable and toxic gases, oxygen, CO2 and refrigerant gases, with catalytic, electrochemical, infrared and photoionisation (PID) sensors.
The SMART 3G series, for classified areas, includes the D2 and C2 models (ATEX category 2, zone 1, plus IECEx), C2-LD with a ring of LEDs, D3 and C3 for zone 2, and GR 1 for mining and tunnels, with ATEX certification for group I. The models with the letter D have a four-digit display and magnet calibration, without opening the enclosure, while those with the letter C are calibrated with a key set. The detectors have a 4–20 mA output, relays and, optionally, RS485 with Modbus protocol, and the certification includes SIL2 for hardware and SIL3 for software. The series detects more than 50 gases.
SMART S is the customisable series, in which the measuring head, base board and enclosure are chosen. The S-SS model is for classified areas, with a stainless steel or copper-free aluminium enclosure, and S-MS is for the marine environment. SMART 3 covers unclassified spaces, including the SMART 3 Blizzard refrigerant gas detector. In large systems, the detectors connect to control units: PL4+ and PL4+D for small installations, MULTISCAN 8+, MULTISCAN++S1 and S2 for up to 256 detectors, and MULTISCAN++MED for 72. The PK system, with the SMART P detector and the MULTISCAN++PK control unit, is built to EN 50545-1 for underground car parks and garages.
What do we supply from the Sensitron range?
| Product | Description |
|---|---|
| SMART 3G | Fixed detectors for classified areas: D2, C2, C2-LD (zone 1), D3, C3 (zone 2) and GR 1 (group I). They have a 4–20 mA output, relays and optionally RS485 Modbus, and the sensors cover flammable and toxic gases, oxygen and CO2. |
| SMART S | Customisable series for severe conditions. S-SS works in classified areas, with a stainless steel or copper-free aluminium enclosure, and S-MS in the marine environment. Both have 4–20 mA, RS485 and, optionally, relays and a HART modem. |
| Control units | PL4+ (4 analogue inputs, expandable to 8), PL4+D (up to 12 detectors), MULTISCAN 8+, MULTISCAN++S1 and S2 (up to 256 detectors) and MULTISCAN++MED (72 detectors). |
| PK system for car parks | SMART P detectors with catalytic and electrochemical sensors, connected to the MULTISCAN++PK control unit. SMART P-2 monitors CO together with NO2 or with petrol vapours at the same time. The system complies with EN 50545-1. |
Why Sensitron?
- SMART 3G in three ATEX versions — zone 1, zone 2 and group I for mining and tunnels
- Catalytic, electrochemical, infrared and PID sensors — chosen according to the gas being monitored, from methane to volatile organic compounds
- Magnet calibration on the D2 and D3 models — done without opening the explosion-proof enclosure
- SIL2 certification for hardware and SIL3 for software — for safety functions
- Control units from 4 analogue inputs up to 256 detectors — the system grows with the installation
Which Sensitron codes and series are requested most often?
| Code | Description |
|---|---|
| SMART 3G D2 | Fixed ATEX category 2 detector, zone 1, with display |
| SMART 3G C2 | Fixed ATEX category 2 detector, zone 1 |
| SMART 3G C2-LD | Fixed zone 1 detector, with a ring of LEDs |
| SMART 3G D3 | Fixed ATEX category 3 detector, zone 2 |
| SMART 3G C3 | Fixed ATEX category 3 detector, zone 2 |
| SMART 3G GR 1 | Detector for mining and tunnels, group I |
| SMART S S-SS | Customisable detector for classified areas |
| SMART S S-MS | Customisable detector for the marine environment |
| SMART P | Detector for car parks, in the PK system |
| PL4+ | Control unit with 4 analogue inputs, expandable to 8 |
| MULTISCAN 8+ | Control unit for 8 detectors 4–20 mA, plus 8 on RS485 |
| MULTISCAN++S2 | SIL2 control unit for up to 256 detectors |
| MULTISCAN++PK | Control unit for the PK car park system |
Where is Sensitron equipment used?
- Energy storage and the paper industry — SMART 3G for flammable and toxic gases in classified areas
- Underground car parks and garages — the PK system for CO and NO2
- Mining and tunnels — SMART 3G GR 1 for methane atmospheres
- Wastewater treatment and the pharmaceutical industry — SMART S for toxic gases
- Refrigeration installations — detectors for refrigerant gases
How do we supply Sensitron in Romania?
We can quote Sensitron fixed gas detectors from the SMART 3G, SMART S and SMART 3 series, control units and accessories for them. For an accurate quotation, send the gas to be measured, the measuring range, the sensor technology, the ATEX zone and group, the required output (4–20 mA, relays, RS485) and the number of measuring points. For replacements, the code on the detector and a photo of the nameplate help with identification. Detectors are supplied to order, usually in 1–4 weeks, and can ship in 24–72 h when the item is in stock, locally or at the supplier. The lead time is confirmed in the quotation.
The exact detector model and the compatible sensor are determined when the request is checked, based on the code on the nameplate.
Frequently asked questions about Sensitron
What does Sensitron make?
Sensitron, based in Cornaredo, Italy, makes fixed gas detectors from the SMART 3G, SMART S, SMART 3 and SMART P series, PL4+, MULTISCAN 8+ and MULTISCAN++ control units, and the PK system for car parks.
What is the difference between SMART 3G D2 and C2?
Both are ATEX category 2 for zone 1. D2 has a four-digit display and magnet calibration, without opening the enclosure, while C2 is calibrated with the STS/CKD+ key set. Send the zone and the gas, and we identify the suitable model.
What gases do the SMART detectors detect?
The SMART 3G series measures more than 50 gases: flammable ones such as methane, LPG, hydrogen and pentane, toxic ones such as CO, ammonia, chlorine and sulphur dioxide, plus oxygen and CO2. The sensors are catalytic, electrochemical, infrared or PID, depending on the gas.
Are Sensitron detectors supplied in Romania, and how fast?
Yes, they are supplied to order, usually in 1–4 weeks, and can ship in 24–72 h when the item is in stock, locally or at the supplier. For systems with control units and many measuring points, the lead time can be longer. We confirm it in the quotation.
What do I send for a gas detector quotation?
Send the gas and measuring range, the ATEX zone and group, the sensor type you want, the output (4–20 mA, relays, RS485) and the number of points. If you are replacing a detector, add the code and a photo of the nameplate.
How do I request a Sensitron quotation?
Send the Sensitron code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: Sensitron Srl (manufacturer documentation)