SIKORA supplier in Romania
For SIKORA we quote LASER Series 2000 and LASER PRO diameter heads, X-RAY 6000 and 8000 systems, CENTERWAVE 6000 and PLANOWAVE 6000, CAPACITANCE 2000 and LUMP 2000 detectors, depending on the extruded product and the line speed.
Founded in 1973 · Headquarters: Bremen, Germany
Who is SIKORA and what does it make?
SIKORA is a German manufacturer based in Bremen, active since 1973, of measuring and quality control instruments for extrusion lines: conductors and cables, optical fibres, hoses, pipes, films and sheets. The instruments measure in-line, without contact, the diameter, wall thickness, ovality, eccentricity, cable capacitance, temperature and surface defects, and the values reach the line control in real time. The range also includes inspection, analysis and sorting systems for plastics.
LASER Series 2000 measures diameters from 0.05 to 500 mm on two or three axes, by analysing the diffraction of a laser beam on a CCD line, with no moving parts; the three-axis version also determines ovality. LASER PRO adds lump detection, up to 5,000 measurements per second per axis and a Wi-Fi connection. Wall thickness and eccentricity are measured with the X-ray systems X-RAY 6000 PRO and PURE and X-RAY 8000 ADVANCED/NXT, which detect up to three layers, with CENTERVIEW 8000, optical and inductive, or with millimetre waves, through CENTERWAVE 6000 and PLANOWAVE 6000, without ionising radiation and without a coupling medium. CAPACITANCE 2000 is mounted in the cooling trough and determines cable capacitance, periodic variations (FFT) and structural return loss (SRL), while LUMP 2000 signals lumps and neck-downs. ECOCONTROL displays collect values, trends and statistics.
Such instruments are installed at cable and conductor manufacturers, at polymer pipe and hose plants and on film and sheet extrusion lines. The choice depends on the product, the diameter range, the number of layers, the line speed and the environment in the cooling zone, which is why the quotation starts from the line data and the existing instrument.
What do we supply from the SIKORA range?
| Product | Description |
|---|---|
| LASER Series 2000 and LASER PRO | Non-contact diameter measuring heads, with a pulsed laser and a CCD line, for transparent or opaque products from 0.05 to 500 mm; LASER PRO adds lump detection and up to 5,000 measurements per second. |
| X-RAY 6000 and X-RAY 8000 | X-ray systems for wall thickness, diameter, ovality and concentricity on pipes, hoses, cables and conductors; X-RAY 6000 PRO measures up to three layers, and PURE is intended for single-layer products. |
| CENTERVIEW 8000, CENTERWAVE 6000 and PLANOWAVE 6000 | Optical and inductive measurement with CENTERVIEW 8000 and millimetre-wave measurement with CENTERWAVE 6000, for round products, and PLANOWAVE 6000, for films and sheets, without ionising radiation and without a coupling medium. |
| CAPACITANCE 2000 and LUMP 2000 | CAPACITANCE 2000 measures cable capacitance in the cooling trough, with FFT and SRL, while the LUMP 2000 detector, in the XY and T versions, signals lumps and neck-downs on the product surface. |
Why SIKORA?
- Non-contact diameter from 0.05 to 500 mm — LASER Series 2000 combines pulsed laser light with a CCD line, with no moving parts
- Wall and eccentricity by X-ray — X-RAY 6000 PRO measures thickness, concentricity and diameter on up to three layers
- Millimetre waves without ionising radiation — CENTERWAVE 6000 and PLANOWAVE 6000 need no coupling medium and adapt to the material by themselves
- In-line capacitance — CAPACITANCE 2000 also determines periodic variations (FFT), structural return loss (SRL) and zones without insulation
- Detection of lumps and neck-downs — LUMP 2000 uses dual sensors, on two or three axes, with a signal to the operator
Which SIKORA codes and series are requested most often?
| Code | Description |
|---|---|
| LASER Series 2000 XY | Two-axis laser diameter head, 0.05–500 mm |
| LASER Series 2000 T | Three-axis diameter head, with ovality |
| LASER PRO | High-precision diameter head, with lump detection |
| LUMP 2000 XY | Lump and neck-down detector, two axes |
| LUMP 2000 T | Lump and neck-down detector, three axes |
| CAPACITANCE 2000 | In-line cable capacitance measurement, with FFT and SRL |
| X-RAY 6000 PRO | X-ray system for products with up to three layers |
| X-RAY 6000 PURE | X-ray system for single-layer products |
| X-RAY 8000 ADVANCED | X-ray system for wall and eccentricity |
| X-RAY 8000 NXT | X-ray system, NXT version |
| CENTERVIEW 8000 | Optical and inductive measurement of wall and eccentricity |
| CENTERWAVE 6000 | Millimetre-wave measurement for round products |
| PLANOWAVE 6000 | Millimetre-wave measurement for films and sheets |
| ECOCONTROL 6000 | 22-inch touch display and control for systems |
| ECOCONTROL PURE | Processor with a 15-inch touch screen |
Where is SIKORA equipment used?
- Cables and conductors — diameter, wall, eccentricity and capacitance on the insulation line
- Optical fibres — in-line control of diameter and surface defects
- Polymer pipes and hoses — wall thickness and ovality during extrusion
- Films and sheets — thickness with millimetre waves on extrusion lines
- Plastics — inspection, analysis and sorting of the material
How do we supply SIKORA in Romania?
We can quote SIKORA instruments for in-line measurement: diameter heads, X-ray or millimetre-wave systems, capacitance and lump detectors, supplied to order. The lead time is usually 1–4 weeks to order, and depending on the specification it can be longer for systems configured on the line. For a quotation, send us the product type (cable, pipe, hose, film), the diameter or thickness range, the number of layers, the line speed, the installation zone (before or after the cooling trough) and the model of the existing instrument, if you are adding to it. The exact lead time is confirmed in the quotation.
The measuring method depends on the product type, the diameter or thickness range and the number of layers, so it is set from the line data.
Frequently asked questions about SIKORA
What does SIKORA make?
SIKORA, based in Bremen and active since 1973, makes in-line measuring instruments for extrusion: diameter, wall thickness, eccentricity, ovality, capacitance, temperature and surface defects. They are used on cables, conductors, optical fibres, hoses, pipes, and plastic films and sheets.
How do I choose between laser, X-ray and millimetre waves for wall thickness?
The laser measures the diameter; wall thickness is found with X-rays or with millimetre waves. X-rays detect up to three layers, while millimetre waves use neither ionising radiation nor a coupling medium. Send us the product, the diameter and the line speed, so that we can recommend the method.
Do you supply SIKORA instruments in Romania and how fast?
Yes, to order, usually in 1–4 weeks; depending on the specification, the lead time can be longer, especially for X-ray systems or systems configured on your line. The exact lead time is confirmed in the quotation.
Can I replace an older SIKORA diameter head with a model from the LASER 2000 series?
This can be checked from the model and serial number of the head, the diameter range, the number of axes and the display used. A match is confirmed from this data; a photo of the nameplate and of the installation on the line speeds up the check.
What do I need to send for a quotation on an X-ray system or CAPACITANCE 2000?
For X-ray, send the diameter and wall thickness, the number of layers and the line speed; for CAPACITANCE 2000, the cable type, the diameter, the length of the cooling trough and the parameters to be checked, such as SRL. The exact installation position on the line also helps.
How do I request a SIKORA quotation?
Send the SIKORA code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: SIKORA AG (manufacturer documentation)