Termotech supplier in Romania
For Termotech we quote Pt100 and Ni100 resistance thermometers, type K, J, N, S, R and B thermocouples, thermocouple cables, thermowells and temperature transmitters; we need the sensor type, the class, the length and the sheath material.
Founded in 1990 · Headquarters: Vigevano, Italy
Who is Termotech and what does it make?
Termotech, based in Vigevano, Italy, designs and builds electrical temperature transducers. The range is divided into five families: resistance thermometers, thermocouples, cables, thermowells and accessories. The sensors appear in industrial furnaces, in plastics installations, in the ceramics and glass industry, in packaging, in the chemical and food industry and in laboratories.
Resistance thermometers have a platinum element, with a nominal resistance between 5 and 1000 Ω, the usual ones being Pt100, Pt500 and Pt1000, to EN 60751, or a nickel element (Ni100, DIN 43760). The Pt accuracy classes are AA, A, B and C, and the general range of use is from -200 to +850 °C. The connection is 2-, 3- or 4-wire, and the construction can be with traditional insulation or with mineral insulation of magnesium oxide (MgO), which allows tight bending and very long probes.
Thermocouples are offered in types K, J, N, E, T, S, R, B, W3 and W5, with tolerances by class to EN 60584-2. Type K works from -270 to +1370 °C, and type S up to 1760 °C. The cables are thermocouple, extension and compensating cables, with glass fibre, silicone, fluoropolymer, PVC or Kapton insulation. Thermowells are made of carbon steel, AISI 304, 316, 310, 446 or Inconel 600, and the temperature transmitters are mounted in the connection head or on a DIN rail, with 4–20 mA output.
What do we supply from the Termotech range?
| Product | Description |
|---|---|
| Resistance thermometers | Sensors with a platinum element (Pt100, Pt500, Pt1000) or nickel element (Ni100), to EN 60751 and DIN 43760. They are made in a construction with traditional or mineral insulation, with 2, 3 or 4 wires and a standard or flameproof connection head. |
| Thermocouples | Thermocouples of types K, J, N, E, T, S, R, B, W3 and W5, with tolerances by class to EN 60584-2. The construction can be with traditional or mineral insulation, with exposed junction, junction bonded to the sheath or insulated junction, to ASTM E-235. |
| Cables for thermocouples | Thermocouple, extension and compensating cables, with glass fibre insulation (up to 400 °C), silicone, MFA fluoropolymer, PVC or Kapton. The tolerances follow DIN 43710, IEC 584 and ANSI MC96.1. |
| Thermowells and accessories | Thermowells in carbon steel, chrome steel, AISI 304, 316, 310, 446 and Inconel 600, with maximum temperatures between 530 and 1212 °C. The accessories include temperature transmitters in the head or on a DIN rail, with 4–20 mA, 0–20 mA or 0–10 V output. |
Why Termotech?
- Pt100, Pt500, Pt1000 and Ni100 resistance thermometers, in classes AA, A, B, C — the accuracy is chosen according to the process and the number of wires
- Mineral insulation with MgO — bendable, long probes, for tight spaces and vibration
- Thermocouples K, J, N, E, T, S, R, B, W3, W5 — from -270 °C up to 2310 °C, depending on the type
- Thermocouple, extension and compensating cables with several insulations — the cable is matched to the temperature and the environment along the route
- Thermowells in stainless steels and Inconel 600, plus 4–20 mA transmitters — complete equipping of the measuring point
Which Termotech codes and series are requested most often?
| Code | Description |
|---|---|
| Pt100 | Platinum resistance thermometer, 100 Ω at 0 °C, EN 60751 |
| Pt500 | Platinum resistance thermometer, 500 Ω at 0 °C |
| Pt1000 | Platinum resistance thermometer, 1000 Ω at 0 °C |
| Ni100 | Nickel resistance thermometer, 100 Ω at 0 °C, DIN 43760 |
| Thermocouple K | NiCr–NiAl, from -270 to 1370 °C |
| Thermocouple J | Fe–CuNi, from -210 to 1200 °C |
| Thermocouple N | Nicrosil–Nisil, similar to type K, with lower hysteresis |
| Thermocouple E | NiCr–CuNi, from -270 to 1000 °C |
| Thermocouple T | Cu–CuNi, from -270 to 400 °C |
| Thermocouple S | Pt10%Rh–Pt, from -50 to 1760 °C |
| Thermocouple R | Pt13%Rh–Pt, from -50 to 1760 °C |
| Thermocouple B | Pt30%Rh–Pt6%Rh, from 0 to 1820 °C |
Where is Termotech equipment used?
- Industrial furnaces — thermocouples and thermowells for high temperatures
- Plastics — temperature sensors for plastics processing installations
- Ceramics and glass — thermocouples for the furnaces and installations of these industries
- Chemical and food industry — resistance thermometers and stainless steel thermowells
- Laboratories and packaging — temperature sensors for laboratory measurements and packaging lines
How do we supply Termotech in Romania?
We can quote Termotech temperature sensors from the families it builds. For an accurate quotation send the element type (Pt100, Ni100 or the thermocouple type), the accuracy class, the number of wires, the insertion length, the diameter, the sheath and thermowell material and the type of connection head. For a transmitter add the output signal and the measuring range. If you are replacing an existing sensor, a photo and the installation drawing speed up identification. Sensors are supplied to order; the exact lead time is set in the quotation.
Sensors built to drawing or with atypical parameters are handled as separate requests, and the possibility of making them is established in the quotation.
Frequently asked questions about Termotech
What families of temperature sensors does Termotech make?
Termotech makes resistance thermometers, thermocouples, cables for thermocouples, thermowells and accessories, that is temperature transmitters in the head or on a DIN rail. Resistance thermometers use Pt or Ni elements, and thermocouples cover types K, J, N, E, T, S, R, B, W3 and W5.
How do I choose between a Pt100 resistance thermometer and a thermocouple?
By maximum temperature, accuracy and atmosphere: Pt100 is suitable up to 850 °C and is made in classes AA, A, B or C, while the thermocouple covers much wider ranges, from -270 °C to 1370 °C for type K.
Do you supply Termotech sensors in Romania, and how quickly?
Yes. Standard sensors are supplied to order in about 1–4 weeks, and an item can ship in 24–72 h when the item is in stock, locally or at the supplier. Versions with a special length, sheath or head may need longer. The time is confirmed with the quotation.
Can I replace an existing sensor with a Termotech one?
Yes, after we check the element type (Pt100, Ni100 or the thermocouple type), the class, the number of wires, the insertion length, the diameter, the sheath material and the process connection. Send the data from the old sensor or a photo; we confirm the match in the quotation.
What data do I send for a Pt100 resistance thermometer or a K thermocouple?
Send the sensor type, the accuracy class, the number of wires for Pt100, the working temperature, the length and diameter, the sheath or thermowell material and the head type. For a cable add the insulation type, and for a transmitter the output signal (4–20 mA, 0–20 mA or 0–10 V).
How do I request a Termotech quotation?
Send the Termotech code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: Termotech (manufacturer documentation)