Who is Tyco and what does it make?
Tyco Fire Products is the Tyco brand of fire protection systems, with valves, sprinklers and components for water-based extinguishing installations. The valve range covers grooved-connection butterfly valves, check and alarm valves for wet systems, valves for dry systems and components for deluge and preaction systems. For the Romanian market we can quote from the Tyco range for sprinkler systems and indoor hydrants.
What sets the Tyco range apart is the complete coverage of the components of a sprinkler system: BFV series butterfly valves, available in grooved versions (BFV-300, 2″-12″, DN50-DN300); the nominal pressure and the connection type are confirmed on the model, from the Tyco Fire data sheet, plus the AV-1-300 alarm valve and the TD-2 test and drain valve for wet systems. For dry systems, the range includes the DPV-1 valve, with a single-clapper construction and external reset, without priming water. For sprinklers, the TY-B, TY-FRB, TY-FRL and TY-L series belong to the standard-coverage range, in several mounting orientations.
In the design and installation of extinguishing systems, the Tyco range fits where UL, FM or ULC certification of the valve or sprinkler is explicitly required by the ISU fire-safety permit or by the insurer. We recommend the brand for new sprinkler projects or for completing an existing system with compatible components.
What do we supply from the Tyco range?
| Product | Description |
|---|---|
| BFV Series Butterfly Valves | Indicating butterfly valve, available grooved (BFV-300, 2″-12″); the nominal pressure and the connection type are confirmed on the model. Typical application: system, section or pump valve. The customer confirms the size and the connection type. |
| DPV-1 Dry System Valve | Pre-trim valve for dry sprinkler systems, with an offset single-clapper design in ductile iron and an external reset that removes the priming water. Typical application: unheated spaces. The customer confirms the pipe size and the air pressure of the system. |
| Wet System Components | AV-1-300 alarm valve, RC-1 retard chamber and TD-2 test and drain valve, for wet sprinkler risers. Typical application: monitoring and periodic testing of the system. The customer states the riser size and the type of alarm required. |
| TY Series Sprinklers | Standard-coverage sprinklers, codes TY-B, TY-FRB, TY-FRL and TY-L, in several mounting orientations. Typical application: spaces with ordinary risk. The customer confirms the activation temperature and the installation environment (corrosive or standard). |
Why Tyco?
- BFV butterfly valves with UL, FM and ULC listings, depending on model and size
- DPV-1 dry system valve, with external reset and no priming water
- TY series sprinklers (TY-B, TY-FRB, TY-FRL, TY-L), in several mounting orientations
- AV-1-300 alarm valve and RC-1 retard chamber for wet systems
Which Tyco codes and series are requested most often?
| Code | Description |
|---|---|
| BFV-1 | butterfly valve, redesign of Central/Grinnell Figure 570/580 |
| BFV-300 | grooved butterfly valve, 2″-12″ |
| BFV-300C | grooved butterfly valve |
| BFV-N | butterfly valve; specifications are confirmed in the Tyco Fire data sheet |
| AV-1-300 | alarm valve for wet systems |
| CV-1FR | riser-type check valve for wet systems |
| RC-1 | retard chamber for the alarm valve |
| RM-2 | riser manifold for sprinkler systems |
| RSV-1 | shut-off valve for residential systems |
| TD-2 | test and drain valve for wet systems |
| WMA-1 | hydraulic alarm with water motor |
| DPV-1 | pre-trim valve for dry systems, external reset |
| TY-B | standard-coverage sprinkler, base series |
| TY-FRB | standard-coverage sprinkler |
| TY-FRL | standard-coverage sprinkler |
| TY-L | standard-coverage sprinkler |
| RFII | standard-coverage sprinkler, RFII series |
Where is Tyco equipment used?
- Fire protection in commercial buildings — TY series sprinklers and control valves
- Warehouses and logistics spaces — BFV butterfly valves for sprinkler networks
- Unheated spaces — DPV-1 dry system valve
- Industrial installations — components for deluge and preaction systems
How do we supply Tyco in Romania?
We supply Tyco valves and components for sprinkler systems, brought in on order through supply channels in the EU. These data come from the manufacturer's public technical documentation; we do not keep this range on the shelf; we confirm availability in the quotation. For an order configured by model, size and certification, usually 1–4 weeks from confirmation. For a quotation, send the exact model or the type of component, the size and the certification required.
We choose the exact model for the European market after checking the local certification required by the project.
Frequently asked questions about Tyco
What does Tyco make for sprinkler systems?
Tyco Fire Products makes butterfly valves, valves for wet and dry systems, deluge/preaction components and sprinklers for fire protection.
How do I choose the right Tyco butterfly valve for my system?
You need the pipe size, the connection type (grooved or flanged) and the maximum working pressure of the system. The BFV-300 model covers grooved connections between 2″ and 12″; other connection types are confirmed on the model.
What is the DPV-1 valve from Tyco?
DPV-1 is the pre-trim valve for dry sprinkler systems, with an offset single-clapper design and external reset, which removes the need for priming water when the system is reactivated.
Can you supply Tyco valves in Romania and in what time?
Yes, we bring in Tyco valves and components on order through supply channels in the EU, usually in 1–4 weeks. The exact lead time depends on the model and the certification required by the project.
How do I request a Tyco quotation?
Send the Tyco code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 12 November 2026 · Sources: Tyco Fire Products LP (Johnson Controls) (manufacturer documentation)

