Waltron supplier in Romania
For Waltron we quote online water chemistry analysers from the LDO 9165, 3140 and 4000 series, sample conditioning modules and consumables; we need the measured parameter, the samples and the process conditions.
Headquarters: Flemington, New Jersey, USA
Who is Waltron and what does it make?
Waltron designs and manufactures online analysers for water chemistry and provides support for them. The range includes analysers for dissolved oxygen, sodium, silica, phosphate, conductivity, hardness, hydrazine, copper, iron and ethylene glycol, sample conditioning modules and consumables: reagents, standards and spare parts. The instruments are installed next to the sampling point, in ultrapure water, steam and cooling water systems.
The LDO series measures dissolved oxygen by the luminescent optical method, from extremely low values, below ppb, with up to four sample streams on a single electronics unit. 9165 is the basic LDO analyser, 9165S is the smart sensor version, and 4165P is the portable version. The 3140 series comprises reagent-based analysers for silica 3141, phosphate 3142, hydrazine 3144, copper 3145, ammonia 3146, iron 3148, ethylene glycol 3149, hardness 3151, monochloramine 3152 and filming amines 3154.
The 4000 series brings together analysers for specific conductivity, electrodeless conductivity and degassed conductivity, pH and ORP and dissolved oxygen, in an IP66 enclosure with two relays and two 4–20 mA outputs. The sample conditioning module adjusts the temperature, pressure and flow of the sample for the analyser. Reagents and standards exist for each parameter, including sodium, silica, dissolved oxygen, hardness, conductivity, iron, phosphate, copper, hydrazine and ethylene glycol. For a quotation, send the parameter, the range and the sample.
What do we supply from the Waltron range?
| Product | Description |
|---|---|
| LDO analysers 9165, 9165S, 4165P | Optical analysers for dissolved oxygen; the 9165 family has a touchscreen, up to four sample streams and flow-independent results. 9165S is the smart sensor version, and 4165P is the portable version for mobile measurements. |
| 3140 series for water and steam chemistry | Reagent-based analysers for silica, phosphate, hydrazine, copper, ammonia, iron, ethylene glycol, hardness, monochloramine and filming amines. They have a modular wetted section, with pump heads replaceable without tools, and a touchscreen. |
| 4000 series for conductivity, pH and oxygen | Models 4000 SC, EC, DC, PH and DO measure specific conductivity, electrodeless conductivity and degassed conductivity, pH and ORP, and dissolved oxygen. They have an IP66 enclosure, two relays and two 4–20 mA outputs; 4073 integrates between one and three channels. |
| Sample conditioning modules | The single sampling point module adjusts the temperature, pressure and flow of the sample: pressure of 0–70 bar for the low-pressure version and up to 350 bar for the high-pressure one, temperature of up to 232 °C or 537 °C. The base plate is made of 304 stainless steel. |
Why Waltron?
- Luminescent dissolved oxygen analysers — the result does not depend on the sample flow
- 3140 series for water-steam cycle parameters — silica, phosphate, hydrazine, copper, iron, ammonia, hardness
- 4000 series with relays and 4–20 mA outputs — connects directly to the plant control system
- Sample conditioning modules supplied assembled — only the cooling water, sample and drain connections remain to be made
- Consumables, reagents and standards for each parameter — the analyser is maintained with the same items
Which Waltron codes and series are requested most often?
| Code | Description |
|---|---|
| 9165 | LDO dissolved oxygen analyser for process |
| 9165S | LDO analyser with smart sensor |
| 4165P | Ultraportable LDO analyser |
| 4000 DO | Luminescent dissolved oxygen analyser, one channel |
| 4000 SC | Specific conductivity analyser |
| 4000 DC | Degassed conductivity analyser |
| 4000 PH | pH and ORP analyser |
| 4073 | Multichannel analyser, from one to three channels |
| 3141 | Silica analyser |
| 3142 | Phosphate analyser |
| 3144 | Colorimetric hydrazine analyser |
| 3145 | Dissolved copper analyser |
| 3148 | Dissolved iron analyser |
| 3152 | Disinfectant analyser, monochloramine |
Where is Waltron equipment used?
- Power generation — monitoring of silica, sodium and oxygen in water and steam
- Ultrapure water — control of silica, phosphate and hydrazine
- Steam and boiler plants — tracking corrosion through dissolved copper and iron
- Cooling water and drinking water — monochloramine and hardness
- Wastewater and basins — monochloramine and other disinfectants
How do we supply Waltron in Romania?
We can quote Waltron analysers from the LDO, 3140 and 4000 series, sample conditioning modules, reagents, standards and spare parts. For a correct quotation we need the measured parameter, the expected range, the sample temperature and pressure, the number of sampling points and the outputs required by your system. If you already have an analyser, add the model and the consumable code. We supply to order, usually in 1–4 weeks, and the quotation gives the confirmed lead time for each item.
The exact composition of the conditioning module and of the consumables set is defined in the quotation, based on the data of the sample and of the sampling point.
Frequently asked questions about Waltron
What analysers does Waltron make?
Waltron makes online analysers for water and steam chemistry: luminescent dissolved oxygen (LDO series), reagent-based analysers for silica, phosphate, hydrazine, copper and iron (3140 series) and conductivity and pH analysers (4000 series). The company also offers sample conditioning modules and consumables.
How do I choose between the 3140 series and the 4000 series?
The 3140 series measures parameters with reagents, for example silica, phosphate or iron, while the 4000 series measures conductivity, pH or oxygen with sensors, with relays and 4–20 mA outputs. Send the desired parameter, the range and the sample, and we work out the suitable series.
Do you supply Waltron consumables in Romania, and how fast?
Yes. Reagents, standards and spare parts are supplied to order, usually in 1–4 weeks, and they can ship in 24–72 h when the item is in stock, locally or at the supplier. Analysers and complete modules may take longer; the confirmed date appears in the quotation.
Can I replace an older dissolved oxygen analyser with an LDO one?
Yes, after checking compatibility. An LDO analyser measures dissolved oxygen optically and does not require sensor maintenance. It is determined by the range, the number of sample streams and the existing outputs. Send the current model, the sample conditions and the outputs in use, and we confirm in the quotation which version fits.
What data should I send for a sample conditioning module?
For the conditioning module, send the sample pressure and temperature, the flow, the parameters analysed and the number of analysers mounted on the plate. The module is supplied assembled, with a stainless steel sink for the grab sample, and the cooling water is connected to 3/8 to 3/4 inch connections.
How do I request a Waltron quotation?
Send the Waltron code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Waltron (manufacturer documentation)