Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Wilo Wilo Rexa PRO

Wilo Rexa PRO submersible pumps for wastewater containing faecal matter and dirty water (with little sand and gravel) in the commercial sector, with single-channel (C) or vortex (V) impeller, DN 50–DN 100 discharge connection, ATEX-approved for zones 1 and 2.

Rexa PRO is the Wilo series of fully submersible wastewater pumps, designed for stationary and portable submerged installation, as well as for stationary dry-well installation (only with the P 13 motor, which has a non-submerged operating mode), in continuous or intermittent duty with stops. According to the series description, the pumps are used in the commercial sector for wastewater containing faecal matter, dirty water (with a low concentration of sand and gravel) and sludge with at most 8 % dry matter, depending on the hydraulic system chosen. The series has two impeller shapes, single-channel (C) and vortex (V), a discharge connection from DN 50 to DN 100, single-phase motors (1~230 V, 50 Hz, with capacitor box) or three-phase motors (3~400 V, 50 Hz) and ATEX approval for explosive atmospheres.

For a quotation, send us the full pump code, for example Rexa PRO-C05-322A/21M011X523/O, or the article number from the nameplate. If you do not have the code, we need the impeller shape (C or V), the diameter of the discharge connection, the rated power P2, the supply voltage, the type of liquid and the solids content, as well as the type of installation (stationary submerged, portable or dry-well). When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.

Models and codes

CodeNote
Rexa PRO-C05-322A/21M011X523/O, art. 6098471Single-channel impeller, DN 50, 1.1 kW, 1~230 V, 50 Hz, free spherical passage 45 mm; ATEX zones 1 and 2.
Rexa PRO-C05-328A/21T025X540/O, art. 6098477Single-channel impeller, DN 50, 2.5 kW, 3~400 V, 50 Hz, free spherical passage 45 mm; ATEX zones 1 and 2.
Rexa PRO-C06-346A/21T039X540/O, art. 6098482Single-channel impeller, DN 65/80, 3.9 kW, 3~400 V, 50 Hz, free spherical passage 45 mm; ATEX zones 1 and 2.
Rexa PRO-C08-412A/21T011X540/O, art. 6098486Single-channel impeller, DN 80, 1.1 kW, 3~400 V, 50 Hz, free spherical passage 55 mm; ATEX zones 1 and 2.
Rexa PRO-C08-436A/21T050X540/O, art. 6098498Single-channel impeller, DN 80, 5 kW, 3~400 V, 50 Hz, free spherical passage 65 mm; ATEX zones 1 and 2.
Rexa PRO-C08-537A/40T045X540/O, art. 6097795Single-channel impeller, DN 80/100, 4.5 kW, 3~400 V, 50 Hz, free spherical passage 80 mm; ATEX zones 1 and 2.
Rexa PRO-C10-512A/40M011X523/O, art. 6098190Single-channel impeller, DN 100, 1.1 kW, 1~230 V, 50 Hz, free spherical passage 100 mm; ATEX zones 1 and 2.
Rexa PRO-C10-518A/40T045X540/O, art. 6076773Single-channel impeller, DN 100, 4.5 kW, 3~400 V, 50 Hz, free spherical passage 100 mm; ATEX zones 1 and 2.

Key specifications

Hydraulic systemsingle-channel impeller (C) or vortex impeller (V); the series page also lists variants with semi-open single-channel impeller; grey cast iron EN-GJL-250
Discharge connectionDN 50, DN 65/80, DN 80, DN 80/100 and DN 100; in the rows with single-channel impeller: C05 DN 50, C06 DN 65/80, C08 DN 80 (types 412–437) or DN 80/100 (types 533–537), C10 DN 100; the manual states PN 10
Free spherical passage45–100 mm, depending on the model; single-channel impeller: C05 and C06 45 mm; C08 DN 80 55 mm (types 412–418) or 65 mm (types 432–437); C08 DN 80/100 80 mm; C10 100 mm; for the vortex impeller variants (V), the free passage is confirmed on the exact code
Rated power P2 and supplyin the rows with single-channel impeller: 1.1; 1.5; 2.5; 3.45; 3.9; 4.5 and 5 kW at 3~400 V, 50 Hz; 1~230 V, 50 Hz (single-phase model with capacitor box) only at 1.1 and 1.5 kW
Temperature, protection and immersionpumped fluid temperature 3…40 °C, maximum 60 °C for 3 min; IP68; insulation class F (H optional); maximum immersion depth 20 m; standard cable 10 m
Operating modessubmerged S1; non-submerged (P 13 motor only) S2-30 min or S3 25 %; maximum switching frequency 50/h on the P 13 motor and 15/h on the P 17 motor
Materialsmotor casing and hydraulic casing EN-GJL-250; impeller EN-GJL-250 (the manual also states EN-GJS-500-7); seal towards the pump SiC/SiC and towards the motor C/MgSiO4; static seals NBR; shaft end stainless steel 1.4021 (AISI 420)
Explosion protectionATEX approval, group II, category 2, zones 1 and 2 (not used in zone 0); the table on the series page marks the rows with ATEX Zone 1, ATEX Zone 2
Monitoringwinding temperature with bimetal sensor (PTC optional); leakage detection in the motor compartment only on the P 13 motor; external electrode for the sealing chamber, optional

The data come from the Rexa PRO series page on the Wilo website for Romania (the product table, the series description and the list of documents) and from the installation and operating instructions Wilo-Rexa PRO, article code 6063548, edition 07, February 2019, 48 pages, published on the same page. The series page is active and does not indicate discontinuation. The table on the series page lists the rows with single-channel impeller (C05–C10); the variants with vortex impeller (V) are confirmed on the exact code. Of the Rexa range, only the PRO series is covered here.

Frequently asked questions

What do C and V mean in the Rexa PRO code?

According to the identification code on the series page, C indicates the single-channel impeller and V the vortex impeller; the next two digits give the nominal diameter of the discharge pipe (05 = DN 50, 06 = DN 65/80, 08 = DN 80, 10 = DN 100; for types C08-533…537, the table on the series page states DN 80/100). The table lists the rows with single-channel impeller, and for a V variant we confirm the data on the full code.

How do we read the power and the voltage from the code?

From the identification code of the series: the letter M indicates single-phase supply and T three-phase supply; the value of the three digits before the letter X, divided by 10, is the rated power P2 in kW (for example 015 means 1.5 kW); the digit 5 after X means 50 Hz, and the code 23 or 40 indicates 230 V and 400 V respectively. The letter O at the end indicates the connection cable with free end.

What options exist compared with the standard version?

The series page lists as options IE3 motors, thermal monitoring of the winding with PTC sensor, winding in insulation class H, static seals in FKM (FPM), Ceram C0 coating for the casing and hydraulic impeller, and special voltages. We confirm availability on a specific code before the quotation.

Other Wilo series

We confirm the exact variant (impeller shape, connection, power, voltage and options) on the full code or on the article number from the nameplate, before the quotation.

Updated: 2026-11-23