Witt & Sohn supplier in Romania
industrial axial and radial fans
Headquarters: Pinneberg, Germany
Who is Witt & Sohn and what does it make?
Witt & Sohn is a German manufacturer of industrial fans headquartered in Pinneberg, near Hamburg, specialising in axial fans, centrifugal fans and jet fans for installations where the failure of one fan stops an entire process. The published range covers axial impellers from the P, N, M, X and Y families, centrifugal fans from the RNZ, RSZ, LRZ, PRZ, MRZ, HRZ and SRZ series, plus jet fans for tunnels, including the manufacturer's own Banana Jet® system. From this portfolio we can quote both standard units from the families above and variants sized for high pressures or temperatures.
The technical difference lies in the range covered: inlet diameters between 250 and 3,550 mm on axial fans, motor powers from 0.1 kW up to 2.0 MW, and on the centrifugal side pressures run from about 400 Pa on the low-pressure RNZ/RSZ series up to 25,000 Pa on the SRZ series, dedicated to ultra-high-pressure applications. The PRZ series reaches a declared efficiency of up to 85%, and the HRZ series up to 81%, with wheels of 9 or 10 backward-curved blades, chosen according to the flow-to-pressure ratio the installation requires. Each unit is configured per project; it is not sold as a fixed catalogue product.
For the Romanian market, the Witt & Sohn range makes sense for road and metro tunnels, on naval or offshore platforms and in industrial installations where the fan must run constantly at out-of-the-ordinary temperatures or pressures, not only for routine hall ventilation.
What do we supply from the Witt & Sohn range?
| Product | Description |
|---|---|
| P/N/M/X/Y Axial Fans | Axial impellers from the P, N, M, X and Y families, with 6, 8 or 12 blades, plus reversible variants PR6, PR8, NR8, MR8. Inlet diameters 250–3,550 mm, motor frame sizes 63–710, powers 0.1 kW–2.0 MW. Send the flow rate, pressure and duct diameter for series selection. |
| RNZ/RSZ Low-Pressure Centrifugal Fans | RNZ/RNN, 9 backward-curved blades, inlet 63–2,500 mm, for high flow rates at moderate pressure. RSZ (RSZ10, RSZ10A, RSZ10B, RSZ12), 10–12 S-blades, general ventilation and extraction. LQZ11 is the variant for abrasive particles. |
| LRZ/PRZ/MRZ/HRZ Medium-High Pressure Centrifugal Fans | LRZ, PRZ and MRZ (9 curved blades) have a declared efficiency of up to 85% on PRZ. HRZ (10 profiled blades) reaches 81% efficiency. |
| SRZ Ultra-High-Pressure Fans and RLN Free Fans | SRZ (SRZ12–SRZ12D), ultra-high pressure, up to 25,000 Pa, for routes with large pressure losses. RLN (RLN6–RLN12), 6–12 blades, installation without a volute casing. The dust variants carry the codes PQZ, MQZ, HQZ, SQZ. |
| Jet Fans and Banana Jet® | Longitudinal ventilation of road tunnels and metro, with heat-resistant units for smoke extraction. Banana Jet® is the manufacturer's own design which, according to the manufacturer, delivers about 30% more flow in the tunnel for the same energy consumption. Selection depends on the tunnel cross-section and the fire scenario. |
Why Witt & Sohn?
- Very wide pressure range — from about 400 Pa on the low-pressure series up to 25,000 Pa on the SRZ series
- Modular axial impellers P/N/M/X/Y — with reversible variants for reversing the direction of air flow
- Management system certifications according to the manufacturer's documentation for its in-house production
- Series dedicated to tunnels and metro — Banana Jet® for longitudinal ventilation and smoke extraction
- Declared efficiency of up to 85% on the PRZ centrifugal series, relevant to operating cost
- Motor power coverage between 0.1 kW and 2.0 MW within the same axial design family
Which Witt & Sohn codes and series are requested most often?
| Code | Description |
|---|---|
| RNZ/RNN | wheel with 9 backward-curved blades, inlet 63–2,500 mm |
| RSZ10 | 10 S-shaped inclined blades, general-purpose ventilation |
| RSZ10A | RSZ variant with shortened blades |
| RSZ10B | RSZ variant with shortened blades |
| RSZ12 | 12 S-shaped inclined blades, somewhat higher pressure |
| RNZ12 | steep blade angle, not for throttling at low flow |
| VPZ | Scirocco-type design, compact, lower efficiency |
| LQZ11 | dust-type impeller for abrasive particles |
| LRZ9 | 9 backward-curved blades, medium pressure |
| LRZ9A | LRZ variant for different operating points |
| PRZ9 | declared efficiency of up to 85% |
| PRZ9B | PRZ variant for medium-high pressure |
| MRZ9 | first of six MRZ9–MRZ9E variants |
| MRZ9C | intermediate variant of the MRZ family |
| HRZ10 | 10 profiled blades, efficiency of up to 81% |
| HRZ10D | variant of the HRZ series |
| SRZ12 | ultra-high pressure, up to 25,000 Pa |
| SRZ12C | variant of the SRZ series |
| RLN6 | free fan, installation without a volute casing, 6 blades |
| RLN10 | free fan, without casing, with 10 blades |
| PQZ | dust conveying variant, medium pressure |
| SQZ | dust conveying variant, high pressure |
Where is Witt & Sohn equipment used?
- Tunnels and metro — longitudinal ventilation and smoke extraction
- Shipbuilding — engine room ventilation on merchant ships
- Offshore installations — fans for marine conditions
- Energy — high-power cooling and process ventilation
- Underground car parks and large halls — jet fans for targeted air movement
- Process industry — pneumatic conveying of particles
How do we supply Witt & Sohn in Romania?
For Witt & Sohn fans we work from the manufacturer's technical documentation: it shows us the available families, but the configuration of each fan (flow, pressure, temperature, wheel material) is set per project, not from a stock catalogue. These fans are supplied to order, usually in 1–4 weeks depending on the configuration and the manufacturer's confirmation. For a quotation we need the flow and pressure required, the working temperature, the supply voltage and, where relevant, noise requirements or the space available for installation. We set the firm lead time after technical confirmation of the configuration.
The availability of a specific configuration is checked technically before the quotation, and warranty-period service stays with the Witt & Sohn network.
Frequently asked questions about Witt & Sohn
What type of fans does Witt & Sohn make?
Witt & Sohn designs axial fans, centrifugal fans and jet fans for tunnels, marine, offshore and industry, without a fixed catalogue of standard products. Each unit is sized for the flow, pressure and temperature specific to the application, starting from the published families — P/N/M/X/Y for axial and RNZ through SRZ for centrifugal. The full technical data come from the manufacturer's technical documentation.
How do I choose the right Witt & Sohn centrifugal fan series?
The choice depends on the pressure required: the RNZ and RSZ series cover low pressure, LRZ/PRZ/MRZ medium pressure, HRZ higher pressure, and SRZ reaches ultra-high pressure, up to 25,000 Pa according to the published data. The number of blades and the shape of the wheel influence the declared efficiency, up to 85% on the PRZ series. Send the flow rate and working pressure for the right selection.
Do you supply Witt & Sohn fans in Romania and how quickly?
Yes, we supply the fans to order, usually in 1–4 weeks, depending on the configuration and the manufacturer's confirmation. Each unit is configured per project and supplied to order. The exact lead time is confirmed after the technical parameters needed for the quotation have been sent.
What parameters should I send for an industrial fan quotation?
For any quotation we need the air flow required, the static pressure of the installation, the working temperature, the motor supply voltage and, where relevant, the material being handled (clean air or air with particles). For tunnel jet fans, add the tunnel cross-section and the design fire scenario. With this data we can identify the right series from the published range.
What is the difference between the Witt & Sohn P, N, M, X and Y axial series?
The difference lies in the angle and number of the impeller blades, with reversible variants such as PR6, PR8, NR8 or MR8 for different directions of rotation. The families cover inlet diameters from 250 to 3,550 mm and motor powers between 0.1 kW and 2.0 MW. The right selection comes from the flow-to-pressure ratio required, not just from the duct diameter.
How do I request a Witt & Sohn quotation?
Send the Witt & Sohn code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Witt & Sohn GmbH & Co. KG (manufacturer documentation)