Wolter supplier in Romania
For Wolter we quote RS, RK, ERM and DRM tubular fans, AXV and BXV axial fans, RVH roof fans and EK and DK duct fans; we need the series, size, air flow and voltage.
Founded in 1971 · Headquarters: Malsch, Germany
Who is Wolter and what does it make?
Wolter GmbH Maschinen- und Apparatebau KG, of Malsch, Germany, has designed and made fans and related equipment since 1971. The programme has six families: duct fans, tubular fans, axial fans, roof fans, centrifugal fans and box-housed fans. Each family is divided into series, and the series is chosen according to the type of mounting, the air temperature and the pressure required by the installation.
The RS, RK, ERM and DRM tubular fans have a centrifugal impeller with backward-curved blades, mounted directly on an external-rotor motor, in protection class IP 44. The RS series covers sizes 100–355 with a steel sheet housing painted by electrostatic process, while ERM and DRM go from 315 to 500. RK has a flame-retardant plastic housing, with an integrated terminal box. The RF series, also tubular, has a galvanised sheet housing and a low height, suitable for false ceilings. The AXV and BXV axial fans have standard diameters between 315 and 1600 mm, air flows of up to 200,000 m³/h and static pressure increases of up to 1,500 Pa, with hot-dip galvanised housings and blades adjustable at standstill. There are also smoke extraction versions, at 300 °C for 60 or 120 minutes and at 400 °C for at least 120 minutes, to DIN EN ISO 12101-3.
The RVH roof fans have an IEC motor in the IMB5 construction form, protection class IP55, placed outside the air stream. The EK(S) and DK(S) duct fans can be mounted in any position and have speed control. What matters for a quotation is the series, the size, the air flow, the pressure, the air temperature and the electrical supply.
What do we supply from the Wolter range?
| Product | Description |
|---|---|
| RS, RK, ERM, DRM tubular fans | Fans with a centrifugal impeller with backward-curved blades, balanced to G 2.5, on an IP 44 external-rotor motor. RS comes in sizes 100–355, ERM and DRM in 315–500, and RK has a flame-retardant plastic housing with an integrated terminal box. |
| AXV and BXV axial fans | Axial fans in a long housing version (LH, external terminal box) or a short one (SH), with standard diameters of 315–1600 mm. They reach air flows of up to 200,000 m³/h, and the blades are fully adjustable at standstill. |
| RVH roof fans | Fans for mounting on different types of roof, with an IEC IMB5 motor, IP55, insulation class F, in 1~230 V or 3~400 V, 50 Hz. The aluminium impeller with backward-curved blades is balanced to G 6.3, and the hood is made of aluminium. |
| EK(S) and DK(S) duct fans | Fans with a rectangular galvanised sheet housing; the EKS and DKS versions have an aluminium profile with sound-insulated panels. The motor has thermal contacts as standard, and the speed is fully controllable. |
Why Wolter?
- RS, RK, ERM and DRM tubular fans with an IP 44 external-rotor motor — they are fitted directly in the duct run, with a straight air flow
- AXV and BXV axial fans, diameters 315–1600 mm — for high air flows in ventilation and process air
- Smoke extraction versions at 300 °C and 400 °C, to DIN EN ISO 12101-3 — they suit installations with fire resistance requirements
- RVH roof fan with the motor outside the air stream — the temperature of the air handled can reach 120 °C
- EK(S) and DK(S) duct fans, speed-controllable and mountable in any position — the motor has thermal contacts as standard
Which Wolter codes and series are requested most often?
| Code | Description |
|---|---|
| RS | Tubular fan with a steel sheet housing, sizes 100–355 |
| RK | Tubular fan with a flame-retardant plastic housing and integrated terminal box |
| ERM | Tubular fan with a steel sheet housing, sizes 315–500 |
| DRM | Tubular fan with a steel sheet housing, sizes 315–500 |
| RF | Galvanised sheet tubular fan, with a three-speed single-phase motor, IP 44 |
| EK(S) | Duct fan with a rectangular galvanised sheet housing |
| DK(S) | Duct fan with a rectangular housing, a version from the same family as EK(S) |
| AXV | Axial fan, standard diameters 315–1600 mm |
| BXV | Axial fan from the same family as AXV, with a long or short housing |
| RVH | Roof fan with an IEC IMB5 motor, IP55 |
Where is Wolter equipment used?
- Building ventilation and air-conditioning installations — duct, tubular and roof fans
- Smoke extraction — AXV and BXV axial fans in versions for 300 °C and 400 °C
- Car parks — ventilation of garages and covered car parks
- Tunnel ventilation — an application area of the fan programme
- Industry — general ventilation and process air
How do we supply Wolter in Romania?
We can quote Wolter fans from the tubular, axial, duct and roof series. For a correct quotation, send the series or the code on the nameplate, the size, the air flow and the pressure required, the air temperature, the type of supply (single-phase or three-phase) and the mounting method. If you are replacing an existing fan, a photo of the nameplate and the diameter of the connection help. Supplied to order, usually in 1–4 weeks, and depending on the series the lead time may be longer; we confirm it in the quotation.
Smoke extraction versions or versions with explosion-protected motors are checked in the quotation, on the basis of the temperature, the operating time and the requirements of the installation.
Frequently asked questions about Wolter
What do the RS, RK, AXV and RVH series cover at Wolter?
RS and RK are tubular fans, RS with a steel sheet housing and RK in flame-retardant plastic with an integrated terminal box. AXV is the series of axial fans for high air flows, and RVH covers the roof fans. ERM and DRM are also tubular, in sizes of 315–500, and BXV belongs to the axial family.
How do I choose between a tubular fan and an axial one?
The tubular fan is fitted in the duct, with a circular connection, and suits a network with pressure losses. The AXV or BXV axial fan moves high air flows, up to 200,000 m³/h, at static pressure increases of up to 1,500 Pa. Send the air flow and the pressure of the network.
Can you supply Wolter fans in Romania, and how fast?
The fans are supplied to order, usually in 1–4 weeks. For special series or smoke extraction versions the lead time may be longer. The exact lead time is confirmed in the quotation, after we receive the series, the size and the operating data.
I have an old Wolter fan. What data do you need for a replacement?
Send a photo of the nameplate with the series, size, voltage, power and speed, plus the diameter of the connection and the mounting method. We check whether the series is still in the programme or which version of the family suits, and we confirm compatibility in the quotation.
What should I send for an RVH roof fan quotation?
Send the size required, the air flow and the pressure, the air temperature (up to 120 °C at fixed speed, 80 °C with a speed-controlled motor) and the supply, single-phase or three-phase. For RVH 800 and larger sizes the temperature limit is lower, and we check it in the quotation.
How do I request a Wolter quotation?
Send the Wolter code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: Wolter GmbH Maschinen- und Apparatebau KG (manufacturer documentation)