Hydraulic filters
The hydraulic filter retains solid particles in the oil of a hydraulic circuit, protecting the pump, directional valves and cylinders from accelerated wear caused by contamination. It is fitted on the suction, pressure or return line, depending on the position in the circuit for which the filter element was designed.
The mounting position determines the design requirements: the suction filter must have a very low pressure drop, so as not to cause pump cavitation, the pressure filter withstands the working pressure of the system, and the return filter cleans the oil before it goes back to the tank, usually at low pressures. The filter element can be made of cellulose paper, synthetic fibre or combinations of the two, and the filtration rating, expressed in micrometres, sets the size of the smallest particles retained. A suitable filter for an industrial circuit has a housing that withstands the maximum pressure of the system, a clogging indicator (visual or electrical) that signals when to replace before the element fails under pressure, and a correctly calibrated bypass valve, to protect the pump in case of sudden clogging. Compatibility of the materials with the type of hydraulic oil used also matters, as does the availability of the replacement element for the same model, to avoid long maintenance stoppages.
How to choose
Mounting position in the circuit: suction, pressure or return
Each position requires a different housing design and pressure drop; a pressure filter fitted on the return line, or the reverse, does not work correctly and can damage the installation.
Filtration rating required (micrometres)
It is chosen according to the contamination sensitivity of the most demanding components in the circuit, usually proportional valves or servo valves, not the least sensitive component.
Maximum pump flow and working pressure
The housing and filter element must be sized for the real flow of the system, otherwise the pressure drop rises above the permitted limit and affects the operation of the circuit.
Type of clogging indicator
A visual indicator is enough for installations with frequent checks, but an electrical indicator, connected to the automation system, signals clogging even in installations with no permanent staff in the area.
Compatibility with the type of hydraulic oil used
The materials of the filter element and seals must withstand the mineral, biodegradable or synthetic oil used, otherwise they degrade prematurely.
Bypass valve opening pressure
A wrongly calibrated valve either lets unfiltered oil through too early, or risks collapsing the filter element before it opens.
Availability and replacement frequency of the filter element
Replacement elements must be easy to obtain for the exact model used, and the real replacement frequency depends on the contamination level of the installation.
What to send for a quotation
- Mounting position in the circuit: suction, pressure or return
- Pump flow and working pressure of the system
- Filtration rating wanted, if already known
- Type of hydraulic oil used
- Code of the existing filter element, if it is a replacement
- Quantity required and delivery date wanted
Typical applications
- Hydraulic power units
- Lubrication systems
- Mobile machinery
- Industrial presses
- Plastic injection moulding installations
Maintenance and spare parts
The filter element clogs progressively as it retains particles and must be replaced when the clogging indicator warns, not at an arbitrarily chosen fixed interval. The condition of the housing seals and the opening pressure of the bypass valve are checked periodically and, when the element is changed, an oil analysis is also recommended, to identify the source of contamination if the filter clogs unusually fast.
Brands we quote for this product type
Frequently asked questions
What is the difference between a suction and a pressure hydraulic filter?
The suction filter has a very low pressure drop, precisely so as not to cause pump cavitation at the oil inlet, and usually a coarser filtration rating. The pressure filter withstands the working pressure of the system and can have a finer filtration rating, to protect the sensitive components downstream.
How is the filtration rating chosen for a hydraulic filter?
Start from the component most sensitive to contamination in the circuit, usually a proportional valve or a servo valve, and choose the rating recommended by its manufacturer, not a generic value for the whole system.
What must be sent for a hydraulic filter quotation, and how long does delivery take?
The mounting position, pump flow, working pressure and filtration rating wanted. Delivery is to order, usually 1–4 weeks, depending on the manufacturer and the availability of the exact filter element.
How often should the element of a hydraulic filter be changed?
Not at a fixed interval, but according to the degree of contamination, signalled by the clogging indicator of the filter. Clogging much faster than usual generally points to a source of contamination in the system, not just a worn filter element.
Updated: 2026-11-20