Alco Controls supplier in Romania
For Alco Controls we quote TI, TX7, T and ZZ expansion valves, 110/200/240 and 540 solenoid valves, ACP and PRE regulators, PS1 and CS1 pressure switches and EX2 electronic valves, on the basis of the refrigerant and the code on the valve.
Who is Alco Controls and what does it make?
Alco Controls is a line of control components for refrigeration, air-conditioning and heat pump circuits. The programme covers thermostatic expansion valves, solenoid valves, mechanical pressure regulators, pressure switches and thermostats, filter driers and moisture indicators, electronic expansion valves and oil management systems. All these elements are fitted on the refrigeration circuit, between the compressor, the condenser and the evaporator, and decide how much refrigerant reaches the evaporator, at what pressure and how clean.
Thermostatic expansion valves maintain the superheat of the vapour at the evaporator outlet: the TI, TIH and TX7 series are sealed (hermetic), while T, ZZ, L and 935 are of the demountable type, with thermostatic heads and interchangeable orifices. The ZZ series is made for evaporating temperatures between −45 and −100 °C, and the L and 935 series are liquid injection valves. The solenoid valves include 110/200/240 (2-way, normally closed), 540 (normally open), 200RH for high pressure and the 3-way M36 for heat recovery. For CO2 (R744) systems there are the CX2 electronic valves, the CV4–6 stepper motor valves and the CS3 safety pressure switch, with a fixed switching point; the CS1 safety pressure switch is adjustable, with a maximum working pressure of 70 bar.
The components appear in cold rooms, dairy and food cooling installations, display cabinets and commercial coolers, ice machines, transport refrigeration, small chillers and heat pumps. The choice depends on the refrigerant, the evaporating temperatures and the capacity, which is why the quotation starts from the code on the valve or from the plant data.
What do we supply from the Alco Controls range?
| Product | Description |
|---|---|
| Thermostatic expansion valves TI, TIH, TX7, T, ZZ | They control the superheat at the evaporator outlet. TI, TIH and TX7 are hermetic, T is demountable with thermostatic heads and interchangeable orifices, and ZZ is for evaporating temperatures between −45 and −100 °C. |
| Solenoid valves 110/200/240, 540, 200RH and M36 | Solenoid valves for refrigeration circuits: the 110/200/240 series with 2 ways normally closed, 540 normally open, 200RH for high-pressure applications and the 3-way M36, used in heat recovery. They are chosen according to the refrigerant, the connection and the coil voltage. |
| Pressure regulators ACP, CPHE, PRC and PRE | ACP and CPHE are hot gas bypass regulators, with CPHE having a double-seat orifice for good part-load behaviour; PRC regulates the pressure in the compressor crankcase, and PRE the pressure in the evaporator. |
| Electronic valves EX2, EX4–8, CX2 and CV4–6 | EX2 and CX2 are electronic expansion valves with pulse-width modulation and interchangeable orifices, CX2 being for CO2 at high pressure; EX4–8 are electrically controlled valves, and CV4–6 are stepper motor valves for CO2. |
Why Alco Controls?
- Hermetic and demountable thermostatic expansion valves — TI, TIH, TX7 for compact installation, T and ZZ with thermostatic heads and interchangeable orifices
- Series for very low temperatures — ZZ works at evaporating temperatures between −45 and −100 °C
- 2-way and 3-way solenoid valves — 110/200/240 normally closed, 540 normally open, 200RH for high pressure, M36 for heat recovery
- Components for CO2 (R744) — CX2 electronic valves, CV4–6 stepper motor valves and the CS3 pressure switch
- Compressor oil management — Traxoil, OilWatch and Level Watch systems for oil and liquid level
Which Alco Controls codes and series are requested most often?
| Code | Description |
|---|---|
| TI | Hermetic thermostatic expansion valve with interchangeable orifices |
| TIH | Thermostatic expansion valve for heat pumps and small chillers |
| TX7 | Compact hermetic thermostatic expansion valve |
| T | Demountable expansion valve, with thermostatic heads and interchangeable orifices |
| ZZ | Expansion valve for evaporating temperatures between −45 and −100 °C |
| L / 935 | Liquid injection valves with interchangeable heads |
| 110 / 200 / 240 | 2-way solenoid valves, normally closed |
| 540 | 2-way solenoid valves, normally open |
| 200RH | 2-way solenoid valves for high pressure |
| M36 | 3-way solenoid valve for heat recovery |
| ACP / CPHE | Hot gas bypass regulators |
| PRC / PRE | Pressure regulators in the crankcase and in the evaporator, respectively |
| EX2 / CX2 | Electronic expansion valves, CX2 for CO2 |
| CS1 | Adjustable safety pressure switch, maximum working pressure 70 bar |
| PS1 / PS2 / PS3 | Single, dual and fixed-point pressure switches |
| Traxoil | Electronic oil level management system |
Where is Alco Controls equipment used?
- Commercial refrigeration — display cabinets, coolers and ice machines
- Cold stores and milk coolers — expansion valves and pressure regulators
- Transport refrigeration — compact hermetic components
- Air conditioning and heat pumps — TIH valves, pressure switches and solenoid valves
- CO2 refrigeration systems — components for R744
How do we supply Alco Controls in Romania?
From the Alco Controls programme we can quote thermostatic expansion valves, solenoid valves, pressure regulators, pressure switches, electronic valves and oil systems, supplied to order. The usual lead time to order is 1–4 weeks and, depending on the specification, it may be longer; a valve can ship in 24–72 h when the item is in stock, locally or at the supplier. For a correct quotation, send us the full code on the valve, the refrigerant, the evaporating temperature, the capacity in kW, the connection type (solder or flange) and, for solenoid valves, the coil voltage. For pressure switches, add the adjustment range and the type of refrigerant.
The equivalence of a valve or a solenoid valve is checked against the full code on the body, the refrigerant and the capacity of the installation.
Frequently asked questions about Alco Controls
What does Alco Controls make?
Alco Controls groups control components for refrigeration circuits: thermostatic and electronic expansion valves, solenoid valves, pressure regulators, pressure switches, thermostats, filter driers, moisture indicators and oil management systems. The parts are fitted in refrigeration, air-conditioning and heat pump installations.
How do I choose a thermostatic expansion valve for my installation?
The choice starts from the refrigerant, the evaporating temperature, the capacity in kW and the connection type. For compact installation, TI, TIH or TX7 are used, and when only the orifice or the thermostatic head must be changed, T. For very low temperatures, between −45 and −100 °C, there is the ZZ series.
Do you supply Alco Controls components in Romania, and how fast?
Alco Controls valves are supplied to order, usually in 1–4 weeks. For a rare code or for a coil with a special voltage the lead time may be longer, depending on the specification. A valve can ship in 24–72 h when the item is in stock, locally or at the supplier. The lead time is confirmed in the quotation.
Can I replace an old Alco solenoid valve with a current type?
It is checked against the full code, the refrigerant, the maximum pressure, the connection type, the coil voltage and the normal state (closed or open). An equivalence is confirmed only after comparing the data; send the code on the body and a photo of the coil, and we check.
What data should I send for a quotation on an Alco pressure switch or solenoid valve?
For the pressure switch: the series (PS1, PS2, PS3, CS1), the adjustment range, the refrigerant and the connection. For the solenoid valve: the series, the connection diameter, the refrigerant, the maximum pressure, the coil voltage and whether it must be normally closed or open.
How do I request a Alco Controls quotation?
Send the Alco Controls code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Copeland (manufacturer documentation)