AMETEK Magnetrol supplier in Romania
Radar, float and displacement level sensors for tanks
Who is AMETEK Magnetrol and what does it make?
AMETEK Magnetrol makes level sensors and switches for liquids and solids, with ranges based on guided wave radar, non-contact radar, float, displacement and ultrasonic technology. The portfolio includes the Echotel family of ultrasonic switches, the Pulsar series of non-contact radars, the Eclipse guided radar transmitter and numerous mechanical float or paddle switch models. For the Romanian market we can quote from the Magnetrol level range published by the manufacturer.
What sets Magnetrol apart is the wide coverage of technologies for the same application — for example, for point level detection both mechanical float switches (T20/T21, T5X/T6X series) and ultrasonic switches with no moving parts from the Echotel family are available. The Pulsar series covers non-contact radar at frequencies of 6, 26 and 80 GHz, for process media of differing difficulty.
For industrial installations in Romania, Magnetrol offers options for almost any level scenario — from simple, robust mechanical switches for boilers, to process radar for tanks with foam or difficult vapours.
What do we supply from the AMETEK Magnetrol range?
| Product | Description |
|---|---|
| Eclipse 706 — Guided Wave Radar Transmitter | Level transmitter with radar guided along a cable or rod, with functional safety versions for safety loops, according to the manufacturer's documentation. |
| Pulsar — Non-Contact Radar (Models R80, R82, R86, R96) | Family of non-contact radar transmitters at frequencies of 6, 26 and 80 GHz, used for level measurement in liquids, sludges and bulk solids, including applications with foam or vapours. |
| Echotel — Ultrasonic Level Switches | Family of ultrasonic switches with no moving parts, available in compact versions (Echotel 940/941), with one or two switching points (Echotel 961/962) or as a transmitter (Echotel Model 355). |
| Genesis — TDR Multiphase Detector | Detector based on TDR (time domain reflectometry) technology for multiphase interfaces, used in oil separators to locate the water-hydrocarbon interface. |
Why AMETEK Magnetrol?
- A wide range of mechanical level switches — float, paddle, disc — for robust applications without sensitive electronics
- Echotel family of ultrasonic switches with no moving parts, in compact versions and with extended functions
- Pulsar series of non-contact radar at 6, 26 and 80 GHz, for process media of differing difficulty
- Eclipse guided radar transmitter, with versions for safety loops, according to the manufacturer's documentation
- Genesis TDR-based detector for multiphase interfaces, useful in oil separators
Which AMETEK Magnetrol codes and series are requested most often?
| Code | Description |
|---|---|
| Eclipse 706 | Guided wave radar transmitter |
| Genesis (ED1/ED2) | TDR-based multiphase detector |
| Pulsar R80 | FMCW non-contact radar, 80 GHz, liquids and solids |
| Pulsar R82 | Pulse burst non-contact radar |
| Pulsar R86 | Non-contact radar, 26 GHz |
| Pulsar R96 | Non-contact radar, 6 GHz |
| Echotel 910 | Ultrasonic level switch |
| Echotel 940/941 | Compact ultrasonic switch, economy range |
| Echotel 961/962 | Ultrasonic switch, one or two points |
| Echotel Model 355 | Non-contact ultrasonic transmitter, current loop |
| Model F10 | Mechanical paddle flow switch |
| Model F50 | Mechanical disc flow switch |
| Model FLS | Floor-mounted level switch |
| Model J52 | Level switch for refrigerant liquid |
| Model T10 | Cable float level switch |
| Model TK1 | Float level switch |
| Models T20/T21 | Float level switch, top mounting |
| Models T5X/T6X | Float level switch, side mounting |
| Models C24/C25 | Level switch for boilers and water columns |
| Thermatel TA2 | Thermal mass flow meter |
| Thermatel TG1/TG2 | Flow/level interface switch with DIN rail mounting |
Where is AMETEK Magnetrol equipment used?
- Oil and gas — multiphase interface and level detection in separators
- Energy — level switches for boilers and water columns (C24/C25 series)
- Chemicals and petrochemicals — process radar for tanks with difficult media
- Food industry — ultrasonic switches with sanitary connections (Echotel 940/941)
- Refrigeration — level switch for refrigerant liquid (Model J52)
- General industry — mechanical level switches for simple tanks
How do we supply AMETEK Magnetrol in Romania?
For any technical confirmation we rely on the manufacturer's currently available technical documentation. Magnetrol equipment is supplied to order, usually 1–4 weeks to delivery, depending on factory confirmation. For a quotation we need the desired technology (radar, ultrasonic, mechanical switch or TDR), the type of fluid and the process conditions (pressure, temperature). Availability for each model in the range is checked in the quotation — this applies to the whole AMETEK Magnetrol range.
Variants for explosion-risk areas and the special wetted materials available for each model are checked item by item, for each order.
Frequently asked questions about AMETEK Magnetrol
What sensors does AMETEK Magnetrol make?
AMETEK Magnetrol makes level sensors and switches for liquids and solids, using guided wave radar, non-contact radar, float, TDR and ultrasonic technology. The range covers both continuous measurement and point level detection.
How do I choose the right Magnetrol level sensor?
The choice depends on the type of fluid, the presence of foam or vapours, and whether continuous measurement or only switching at a threshold is needed. The Eclipse guided radar covers many difficult applications, while mechanical switches remain the robust option for boilers and simple tanks.
What frequencies does the Magnetrol Pulsar series offer?
The Pulsar series offers non-contact radar at 6, 26 and 80 GHz; the final choice depends on the frequency suited to the medium being measured.
How long does delivery to Romania take for AMETEK Magnetrol products?
We supply Magnetrol equipment to order, usually in 1–4 weeks to delivery. This range is supplied to order, and the final lead time depends on factory confirmation for each model.
What do I need to send for a Magnetrol sensor quotation?
Send the desired technology (radar, ultrasonic, mechanical switch or TDR), the type of fluid measured and the process conditions — pressure, temperature, presence of foam — so that we can identify the suitable model and its availability.
How do I request a AMETEK Magnetrol quotation?
Send the AMETEK Magnetrol code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: AMETEK Measurement & Analytical (manufacturer documentation)