Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Cemp supplier in Romania

IEC explosion-proof electric motors for hazardous areas

Founded in 1954 · Headquarters: Senago, Milan, Italy

Request a quote

Who is Cemp and what does it make?

Cemp is an Italian manufacturer of explosion-proof electric motors for hazardous areas, headquartered in Senago, near Milan, specialising in ATEX and IEC Ex motors since 1954. The range includes motors for gas zones (the E..AB/E..AC, E..DB/E..DC, E..HB/E..HC series), motors for dust zones and non-sparking environments (the E..AN/E..AD/E..AQ series) and motors for safe areas from the TCA and TCI series. From this portfolio we can quote motors from 0.12 kW up to 375 kW, in IEC frames from 63 to 355 (the limits depend on the series).

What sets Cemp apart is the full coverage of ATEX categories on the same construction platform — from gas motors (category G) to dust motors (category D) and G/D combinations — plus IE3 and IE4 efficiency in the standard series (IE1 and IE2 available). The associated brands Marathon and ROTOR hold marine approvals from Lloyd’s Register and DNV for the naval variants. The TCN and TCT series cover the same non-sparking requirements, but with production declared entirely in Italy.

Cemp suits oil and gas installations, mining or the marine industry where the ATEX or IEC Ex standard is explicitly required for the installed motor, whether the risk comes from flammable gases or from combustible dust.

What do we supply from the Cemp range?

ProductDescription
ATEX Motors for Gas Zones, Series E..AB/E..ACExplosion-proof motors for areas with a risk of flammable gases, IE3-IE4 efficiency, power from 0.12 to 375 kW, in IEC frames from 63 to 355, in line with IEC 60079-0, 1, 7 and 31 for explosion-proof construction.
ATEX Motors Series E..DB/E..DC and E..HB/E..HCAdditional variants of motors with brake for gas zones.
Non-Sparking and Dust Motors Series E..AN/E..AD/E..AQMotors for areas with a risk of combustible dust or with a non-sparking construction requirement, ATEX categories 3G, 2D and 3D, the same power range from 0.75 to 375 kW, for installations in the food industry, woodworking or mining.
Safe-Area Motors TCA/TCI and Non-Sparking TCN/TCTStandard motors for areas without explosion risk from the TCA and TCI series (the latter marked Made in Italy), plus the non-sparking variants TCN and TCT, marked Made in Italy; all have IE3-IE4 efficiency and power of 0.75–375 kW, in IEC frames 80–355.

Why Cemp?

  • The range covers the ATEX categories — gas, dust and combinations — on the same construction platform
  • IE3 and IE4 efficiency in the standard series, with IE1 and IE2 available
  • Lloyd’s Register and DNV marine approvals for the naval variants, through the associated brands
  • TCN/TCT series with production declared entirely in Italy, for European-origin requirements
  • Power from 0.12 to 375 kW in IEC frames from 63 to 355, depending on the series

Which Cemp codes and series are requested most often?

CodeDescription
E..ABATEX motor for gas zones, IE3-IE4
E..ACATEX motor for gas zones, E..AB variant
E..DBMotor with brake for gas zones, series E..DB/E..DC, Ex db housing
E..DCMotor with brake for gas zones, E..DB variant
E..HBMotor with brake for gas zones, series E..HB/E..HC
E..HCMotor with brake for gas zones, E..HB variant
E..ANNon-sparking/dust motor, series E..AN/E..AD/E..AQ (ATEX 3G, 2D, 3D)
E..ADNon-sparking/dust motor, series E..AN/E..AD/E..AQ (ATEX 3G, 2D, 3D)
E..AQNon-sparking/dust motor, series E..AN/E..AD/E..AQ (ATEX 3G, 2D, 3D)
TCASafe-area motor, IE3-IE4
TCISafe-area motor, marked Made in Italy
TCNNon-sparking motor, production entirely in Italy
TCTNon-sparking motor, TCN variant

Where is Cemp equipment used?

  • Oil and gas — explosion-proof motors for installations with a risk of flammable gases
  • Marine industry — motors with Lloyd’s Register and DNV approvals, through the associated brands
  • Mining — motors for areas with combustible dust
  • Woodworking and food industry — non-sparking motors for dusty environments
  • Mission-critical industrial applications — Ex motors for installations with no tolerance for shutdown

How do we supply Cemp in Romania?

We supply Cemp explosion-proof motors on the basis of the catalogues published by the Italian manufacturer; we confirm availability in the quotation. We bring the motors in made to order, usually in 1–4 weeks from confirmation of the required power, frame and ATEX category; for common accessories or spare parts we can check options with delivery in 24–72 h when the item is in stock, locally or at the supplier. For a quotation, send the power in kW, the IEC frame, the type of hazardous zone (gas or dust) and the exact ATEX category required by the project.

The equivalence of an ATEX category with a motor of another make is established by comparing the technical certificates.

Frequently asked questions about Cemp

What does Cemp manufacture?

Cemp makes explosion-proof electric motors for areas with explosion risk, with ATEX and IEC Ex certification, plus non-sparking motors and motors for safe areas, at the plant in Senago, near Milan, active since 1954.

How do I choose the right Cemp motor for my Ex zone?

Send us the type of risk in the installation (flammable gases or combustible dust), the ATEX category required by the project, the required power in kW and the IEC frame. The E..AB/E..AC/E..DB/E..DC/E..HB/E..HC series cover gas zones, and E..AN/E..AD/E..AQ cover dust zones.

Do you supply Cemp motors in Romania and within what lead time?

Yes, we bring in Cemp motors made to order, usually in 1–4 weeks from confirmation of the technical specifications and of the ATEX category required by the installation.

What is the difference between Cemp TCA and TCN motors?

TCA is a series for areas without explosion risk (safe areas), while TCN is a non-sparking series certified ATEX and IEC Ex (categories II3G, II3G/II2D, II3GD), manufactured in Italy.

What data do I need to send for a Cemp motor quotation?

You need the power in kW, the IEC frame, the supply voltage, the type of hazardous zone (gas or dust) and the exact ATEX category required (for example 2G, 3G, 2D, 3D) according to the project.

How do I request a Cemp quotation?

Send the Cemp code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Cemp S.r.l. (manufacturer documentation)