Who is Danfoss and what does it make?

Danfoss is an important manufacturer in the refrigeration and automation industry. Founded in 1933 in the Danish town of Nordborg, the company expanded globally while staying focused on energy efficiency, precise control and long-term reliability.

The Danfoss range is wide: control valves (pressure, temperature, flow), inverters for motors and pumps, compressors for commercial refrigeration and heat exchangers. Danfoss thermostatic valves are frequently used in professional cooling systems in the food industry, and the inverters for HVAC installations are frequently used in office buildings.

In industrial hydraulics, Danfoss on/off directional valves carry the Vickers by Danfoss brand; for example, DG4V-3 directly solenoid-operated hydraulic directional valves mount on the D03/NG6 interface, and for a quotation the model code from the nameplate is enough for us.

We supply to order, through EU supply channels, the Danfoss equipment requested by customers.

What do we supply from the Danfoss range?

ProductDescription
Industrial valves (control, pressure, thermostatic)Danfoss produces a varied range of valves. Modulating control valves for steam, gases and liquids are frequently used in the chemical and food industries. Differential pressure valves maintain exact parameters in heating and cooling systems, and thermostatic valves for refrigeration (TUA, TUAE series) are frequently used in commercial cold rooms. We supply them with electric or pneumatic actuators, depending on the application.
Inverters and drives for electric motors (VLT)The VLT series is the Danfoss range of frequency converters. They are frequently used on pumps, fans, compressors, conveyor belts – anywhere precise motor speed control is needed. A motor running non-stop at fixed speed can consume significantly less with a VLT inverter with load-adapted control. In addition, soft starts eliminate mechanical shocks and can extend motor life.
Compressors for commercial refrigerationDanfoss scroll and reciprocating compressors are frequently used in shops, restaurants and cold stores. The Maneurop series is a range of reciprocating compressors (MT and MTZ for high and medium temperatures, NTZ for low temperatures). For smaller installations (refrigerated display cases, ice machines), SC series hermetic compressors are a frequent choice. The operating life of Danfoss compressors, with periodic maintenance (oil change), is usually long.
Plate heat exchangersDanfoss brazed plate heat exchangers (XB series) are compact, efficient and resistant to high pressures. They are frequently used in underfloor heating systems, glycol cooling, and heat recovery from industrial processes. Heat transfer is superior to classic shell and tube exchangers, and the space occupied is smaller. Standard sizes are available to order, and for special applications custom variants are ordered, with the thermal calculation set from the application data.

Why Danfoss?

  • Technology geared towards energy efficiency, documented by the manufacturer
  • Precise Danish technology for automatic control in industry
  • Range: from simple valves to integrated energy management systems
  • High durability, according to the manufacturer's specifications
  • Supply through EU channels

Which Danfoss codes and series are requested most often?

CodeDescription
iC2-MicroCompact drive for small applications, successor to the VLT Micro Drive FC 51
VLT Midi Drive FC 280Medium-size drive for industrial machines
VLT Refrigeration Drive FC 103Drive dedicated to commercial refrigeration applications
VLT AutomationDrive FC 302Universal drive for industrial automation
VLT AQUA Drive FC 202Drive dedicated to pumps and water stations
VLT HVAC Drive FC 102Drive dedicated to HVAC fans and pumps
VLT Lift Drive LD 302Drive dedicated to lifting systems and lifts
VLT Decentral Drive FCD 302Drive mounted directly on the motor, decentralised design
VLT DriveMotor FCP 106Motor with integrated drive, compact design
VLT DriveMotor FCM 106Motor with integrated drive for machine mounting
VLT Integrated Servo Drive ISD 410Servo motor with integrated control electronics
VLT Integrated Servo Drive ISD 510Integrated servo motor, ISD 510 generation
VLT Soft Start Controller MCD 100Simple soft starter for motor starting
VLT Compact Starter MCD 201Compact soft starter for low-power motors
VLT Soft Starter MCD 500Advanced soft starter for high-power motors
VACON 20Compact drive for machines and equipment
VACON 100 INDUSTRIALDrive for general industrial applications
VACON 100 FLOWDrive dedicated to pumps and fans
VACON NXP Air CooledModular air-cooled drive, for high power
VACON NXP Liquid Cooled DriveModular liquid-cooled drive, for high power
Vickers DG4V-3Vickers by Danfoss hydraulic directional valve for the D03/NG6 interface, solenoid operated

Where is Danfoss equipment used?

  • Commercial and industrial refrigeration
  • HVAC (heating, ventilation, air conditioning of buildings)
  • Food and beverage industry
  • Chemical and petrochemical industry
  • Water treatment and pumping stations
  • Marine and offshore
  • Renewable energy (heat pumps, solar thermal)
  • Automotive and industrial production

How do we supply Danfoss in Romania?

For Danfoss equipment we work from the manufacturer's technical documentation and technical catalogues; lead time and availability are specified in the quotation. We supply to order, through EU supply channels, control valves, VLT inverters, compressors for commercial refrigeration and plate heat exchangers. For frequently requested items we can sometimes offer 24–72 h when the item is in stock, locally or at the supplier; to order, the lead time is usually 1–4 weeks, and depending on the brand and specifications it can be longer. To prepare a correct quotation, send us the full product code, the quantity and, if available, the data sheet or the application drawing. Quotations are prepared for each request; availability is checked at source before quoting.

We check the availability of each Danfoss item on request, before setting a lead time; service during the warranty period is carried out exclusively through the Danfoss network.

Frequently asked questions about Danfoss

How do I read the code of a Danfoss drive, for example FC 102?

The VLT prefix shows the Danfoss drive family, and the FC number indicates the purpose: 102 is dedicated to HVAC applications, 202 to pumps and water stations, and 302 is the universal variant for automation. For exact power and supply voltage we always check the data sheet for the full code, not just the FC series mentioned verbally by the customer.

What power ratings and supply voltages does the Danfoss iC2-Micro drive, successor to the VLT Micro Drive FC 51, offer?

The iC2-Micro succeeds the VLT Micro Drive FC 51 and is designed to replace it in existing installations. Power ratings are 0.37–2.2 kW at 1 × 200–240 V AC, 0.37–1.1 kW at 1 × 100–120 V AC, 0.37–11 kW at 3 × 200–240 V AC and 0.37–22 kW at 3 × 380–480 V AC. We confirm the exact variant in the quotation.

What do I need to specify for a Danfoss drive quotation?

We need the motor power in kW, the supply voltage, the type of application, pump, fan or conveyor belt, and whether a harmonic filter or dynamic brake is needed. When you are replacing an existing drive, a photo of the label with the full FC code reduces the risk of choosing a variant incompatible with the installation.

What is the difference between the Danfoss VLT and VACON ranges?

VLT is the traditional Danfoss line, with application-specific ranges such as HVAC Drive or AQUA Drive. VACON is a complementary line, geared towards general industrial and process applications with modular configuration. The choice depends on the specific application and on preference for the configuration interface of each range.

How do I request a Danfoss quotation?