DV Power supplier in Romania
test instruments for circuit breakers, transformers, batteries and electrical network safety systems
Founded in 2000 · Headquarters: Stockholm, Sweden
Who is DV Power and what does it make?
DV Power is the trade name of IBEKO Power AB, a Swedish manufacturer headquartered in Stockholm, founded in 2000. The company develops test instruments for electrical networks - circuit breaker analysers and timers, micro-ohmmeters and transformer turns ratio testers for transformers, as well as capacity and discharge testers for stationary batteries. The products have the quality and environmental certifications specified in the manufacturer's documentation and are used by electricity distribution and transmission companies in over 100 countries.
The family of micro-ohmmeters for transformers covers three levels: the RMO-TW series for basic measurements, the RMO-TD series with DRM function and measurement of the on-load tap changer (OLTC) motor current, and the RMO-TT series, with 4 temperature channels, for situations where temperature variation affects the result. For three-phase transformers, the TWA series offers simultaneous measurement on all three phases; the advanced models TWA400 and TWA500 have 7-inch and 10.1-inch touch screens respectively, while TWA25A and TWA40D have an LCD display. For stationary batteries, the BLU series covers voltage ranges from below 1 V up to 1,350 V DC and discharge currents of up to 350 A, with the DV-Win software for generating reports.
For a relay protection and automation (PRAM) laboratory or a maintenance department in the Romanian power system, the DV Power range offers portable instruments for testing circuit breakers, transformers and stationary batteries, usable in the field without complex installation.
What do we supply from the DV Power range?
| Product | Description |
|---|---|
| RMO-TT Micro-ohmmeters | The RMO-TT series (RMO40TT, RMO60TT, RMO100TT) is the single-phase micro-ohmmeter in the range with an integrated tap changer analyser and 4 temperature measurement channels, useful for compensating the result according to the winding temperature. It tests the winding resistance of transformers, generators and motors, with adjustable test current and reporting through the DV-Win software. The difference between the three models lies in the maximum test current available, not in the basic functions. |
| RMO-TD Micro-ohmmeters | The RMO-TD series (RMO25TD, RMO40TD, RMO60TD) adds dynamic resistance measurement (DRM) and measurement of the tap changer drive motor current during on-load switching, which helps detect worn contacts before they become a major failure. It is designed for maintenance teams that periodically test transformers with OLTC (on-load tap changer) and need a single instrument for resistance and tap changer diagnostics. |
| BLU-C Battery Dischargers | The BLU-C series (from BLU100C to BLU800C) discharges stationary batteries in the 3.0–800 V DC range, with a test current of up to 300 A and a maximum power of 42 kW, a 7-inch touch display and a weight of roughly 19 to 28.5 kg depending on the model. It checks the real autonomy of batteries in uninterruptible power supply systems and electrical substations, where a weak battery discovered only during a power cut can disable the protection of the installation. |
| CAT 500 Series Circuit Breaker Analyser and Timer | The CAT 500 series is the circuit breaker analyser and timer, used for measuring switching times, contact travel, contact resistance and other analogue signals during the opening-closing operation, to detect worn contacts or a misadjusted mechanism before a failure. |
Why DV Power?
- Family of micro-ohmmeters - from the basic RMO-TW series to RMO-TT with 4 temperature channels
- TWA three-phase testers for simultaneous measurement on all three phases, with a 7-inch or 10.1-inch touch screen on models TWA400 and TWA500
- BLU battery dischargers, from below 1 V up to 1,350 V DC, with currents of up to 350 A
- Certifications specified in the manufacturer's documentation, for quality and environmental management
- Global presence in over 100 countries
Which DV Power codes and series are requested most often?
| Code | Description |
|---|---|
| TWA500 | three-phase micro-ohmmeter, 10.1-inch touch screen |
| TWA400 | three-phase micro-ohmmeter, 7-inch touch screen |
| TWA25A | three-phase micro-ohmmeter, LCD display, DV-Win software |
| TWA40D | three-phase micro-ohmmeter, LCD display, standard configuration |
| RMO40TT | single-phase micro-ohmmeter, tap changer analyser, 4 temperature channels |
| RMO60TT | single-phase micro-ohmmeter, higher test current, 4 temperature channels |
| RMO100TT | single-phase micro-ohmmeter, high test current, 4 temperature channels |
| RMO25TD | single-phase micro-ohmmeter with DRM and OLTC motor current |
| RMO40TD | single-phase micro-ohmmeter, DRM, OLTC motor current, medium current |
| RMO60TD | single-phase micro-ohmmeter, DRM, OLTC motor current, high current |
| RMO10TW | basic single-phase ohmmeter, low current |
| RMO30TW | basic single-phase ohmmeter, medium current |
| RMO50TW | basic single-phase ohmmeter, higher current |
| BLU1350D | battery discharger 0–1,350 V DC, up to 100 A, 40 kW |
| BLU100C | battery discharger from the BLU-C series (3–800 V DC, up to 300 A, 42 kW per series) |
| BLU500C | battery discharger from the BLU-C series (3–800 V DC, up to 300 A per series), 7-inch touch screen |
| BLU700C | battery discharger from the BLU-C series (weight 18.9–28.5 kg per series) |
| BLU110T | battery discharger from the BLU-T series (0.9–70.5 V DC, up to 350 A per series) |
| BLU220T | battery discharger from the BLU-T series (weight 12.8–15.1 kg per series) |
| BLU100A | battery discharger from the BLU-A series (3–500 V DC, up to 240 A per series) |
| TWR250B | transformer turns ratio tester |
| CAT 500 Series | circuit breaker analyser and timer, switching time measurement |
Where is DV Power equipment used?
- Electricity distribution and transmission - periodic tests on circuit breakers and transformers in substations
- Transformer manufacturers and service - winding resistance and turns ratio checks
- Data centres and UPS - checking the real capacity of stationary batteries
- Electrical substations - diagnostics of circuit breaker operating mechanisms
How do we supply DV Power in Romania?
The technical data comes from the manufacturer's documentation. We supply to order micro-ohmmeters, transformer turns ratio testers, circuit breaker analysers and battery dischargers from the DV Power / IBEKO Power AB range, usually in 1–4 weeks. This range is supplied to order - each order is confirmed on the exact model before being sent for sourcing. For a correct quotation we need the exact model, the test current or voltage required and any accessories specific to the application.
The complete technical parameters (maximum test current, accuracy) for each model in the RMO and BLU series are taken from the individual datasheet, and the cables and application-specific accessories are set separately at order.
Frequently asked questions about DV Power
What do DV Power instruments test?
DV Power instruments test circuit breakers (analysers and timers), transformers (micro-ohmmeters, turns ratio testers) and stationary batteries (capacity and discharge testers), and are built for maintenance teams in the power system and relay protection and automation (PRAM) laboratories.
What is the difference between the RMO-TW, RMO-TD and RMO-TT series from DV Power?
RMO-TW is the basic series, for simple measurement of winding resistance. RMO-TD adds dynamic resistance measurement (DRM) and measurement of the tap changer motor current under load. RMO-TT also includes 4 temperature channels for compensating the result.
How long does supply take in Romania for DV Power equipment?
We bring in to order micro-ohmmeters, transformer testers, circuit breaker analysers and battery dischargers from the DV Power range, usually in 1–4 weeks, depending on the manufacturer's confirmation.
What data do you need for a quotation on a BLU battery model?
For a correct quotation, send the exact model (for example BLU500C), the nominal voltage and the discharge current required, plus the number of cells or blocks in the battery tested, so that we confirm the compatibility of the instrument with your installation.
How do I request a DV Power quotation?
Send the DV Power code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: DV Power (IBEKO Power AB) (manufacturer documentation)