Elettrotec supplier in Romania
For Elettrotec we quote mechanical pressure switches from the PMC, PPC, PMB, PSM and PHP series, PDE and PDV differential pressure switches, TER, TBG and NTB thermostats, GRL level switches, FPR and IF flow switches and TFM variable-area flowmeters; we need the code and the setting range.
Founded in 1977 · Headquarters: Milan, Italy
Who is Elettrotec and what does it make?
Elettrotec, based in Milan, has produced fluid control devices since 1977: electromechanical and electronic sensors and devices for pressure, temperature, level and flow. The devices switch an electric circuit on or off when the fluid reaches a set value, or send the value to the automation system.
For pressure, the programme includes adjustable mechanical pressure switches with changeover contacts (PMC, PPC, PMN, PMM, PM250, PMB, NPS, PSM, PSP, PSK, PHP, PHC and others), vacuum switches, ATEX versions, differential pressure switches with clogging indicator (PDE, PDV) and electronic pressure transmitters, including EPX02. For temperature, non-adjustable thermostats (NTB, NTBC, NTR, EBT, EBC, TBF EVO), bimetallic thermostats and adjustable immersion thermostats (TER) and the compact TBG thermostat. For level, the adjustable GRL level switch, level switches with one or two switching points, level probes and visual indicators, including in ATEX versions.
For flow there are paddle flow switches for liquids (FPR), adjustable flow switches and indicators, visual and electrical (IF-V, IF-VE, IF-V2E, IF-E, IF-DE, IFE, IF2E, CFV) and variable-area flowmeters (TFM-V, TFM2E, FMP-V, FMP-VR, FMX-VR, EPF). The right device is chosen by setting range, fluid, connection, voltage and contact current, so the full code and a photo of the nameplate are the basic data for a quotation. If the device works in an explosive atmosphere, state the zone, because ATEX versions of pressure switches, vacuum switches and level switches exist.
What do we supply from the Elettrotec range?
| Product | Description |
|---|---|
| Pressure switches and pressure transmitters | Adjustable mechanical pressure switches (PMC, PPC, PMB, PSM, PHP, PHC), vacuum switches, ATEX pressure switches and PDE and PDV differential pressure switches with clogging indicator, plus electronic transmitters such as EPX02. |
| Thermostats | Non-adjustable thermostats NTB, NTBC, NTR, EBT, EBC and TBF EVO, bimetallic thermostats with custom-length stem, the compact TBG thermostat, the TCR thermostat with power relay and the TER adjustable immersion thermostat. |
| Level switches and level probes | The adjustable GRL level switch, standard level switches with one or two switching points, intrinsically safe and explosion-proof ATEX versions, level probes and visual indicators. |
| Flow switches and flowmeters | The FPR paddle flow switch for liquids, adjustable flow switches of the IF series, CFV propeller indicators and variable-area flowmeters TFM, FMP, FMX and EPF, with or without adjustable electrical contacts. |
Why Elettrotec?
- Four variables controlled with the same brand — pressure, temperature, level and flow
- Mechanical pressure switches with changeover contacts, in many connection and range variants — including high-performance (PHP) and low-pressure (PHC) versions
- PDE and PDV differential pressure switches — they indicate filter clogging
- ATEX versions for pressure switches, vacuum switches and level switches — for zones with explosion hazard
- Flow switches and variable-area flowmeters, including for oxygen — for liquid and gas circuits
Which Elettrotec codes and series are requested most often?
| Code | Description |
|---|---|
| PMC | Adjustable pressure switch with changeover contacts |
| PPC | Adjustable pressure switch with changeover contacts |
| PMB | Basic series pressure switch |
| PHP | Adjustable high-performance pressure switch |
| PDE | Differential pressure switch with clogging indicator |
| EPX02 | Electronic pressure transmitter |
| TER | Adjustable immersion thermostat |
| TBG | Compact thermostat |
| NTB | Non-adjustable thermostat with 360° rotating head |
| GRL | Adjustable level switch |
| FPR | Paddle flow switch for liquids |
| TFM-V | Variable-area flowmeter |
Where is Elettrotec equipment used?
- Hydraulics and pneumatics — pressure switches for circuit protection
- Food and pharmaceutical industry — control of process fluids
- Rail transport — devices for pressure and temperature control
- Heating and cooling installations — thermostats, flow switches and level switches
- Explosive atmosphere zones — ATEX pressure switches and level switches
How do we supply Elettrotec in Romania?
We can quote Elettrotec pressure switches, thermostats, level switches, flow switches and flowmeters. For a quotation, send the full code or a photo of the nameplate, the setting range, the connection type, the voltage and contact current, the fluid and the working temperature. Items can ship in 24–72 h when the item is in stock, locally or at the supplier; those supplied to order, usually take 1–4 weeks. The exact lead time appears in the quotation.
A device withdrawn from the programme is replaced according to setting range, connection and contacts, which we confirm in the quotation.
Frequently asked questions about Elettrotec
What does Elettrotec make?
Fluid control devices: pressure switches, thermostats, level switches, flow switches and flowmeters, mechanical and electronic, on the market since 1977. The headquarters is in Milan, Italy.
How do I choose between a mechanical pressure switch and an electronic transmitter?
The mechanical pressure switch changes a contact at a set value and suits pump protection and starting. The electronic transmitter gives a continuous signal to the automation system. The application and the signal required by the PLC point to the right version.
How is an Elettrotec PMC pressure switch code read, for example PMC10DFV18K T5D?
The code reads by position: PMC is the pressure switch with changeover contacts, 10 is the 1–10 bar adjustment range, D means two changeover contacts, F zinc-plated steel flange, V FKM diaphragm, 18K G 1/8 BSPT taper thread and T5D a falling set-point at 5 bar. We confirm the full code with the quotation.
Can I replace an Elettrotec pressure switch with an old code?
Usually yes, if the setting range, connection and contact type are kept. Send the code or a photo of the nameplate; we check whether the series is still in the programme, and you receive the answer in the quotation.
For a quotation on an Elettrotec PMC series pressure switch, what data do I send?
The fluid, temperature, pressure, connection, voltage and contact current, and the setting range. For zones with explosion hazard, state the zone and the gas, because the ATEX version differs.
How do I request a Elettrotec quotation?
Send the Elettrotec code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Elettrotec S.r.l. (manufacturer documentation)