Who is EPRO Gallspach and what does it make?

EPRO Gallspach GmbH was founded in October 1994 at Gallspach, in Austria. Since then the company has moved from series production to custom, high-accuracy test equipment for high-voltage laboratories, metrology institutes and transformer manufacturers.

The product line is closely tied to testing and calibration standards. Test transformers raise the voltage in the laboratory, from 20 kV up to 600 kV, at continuous powers of 5 to 60 kVA, and above 200 kV they are built in cascade. Reference voltage transformers (from 50 V to 800/√3 kV) and reference current transformers are purely inductive, passive devices that serve as standards for calibrating other instrument transformers; their accuracy is maintained in the range 40–120% of the rated voltage. The TRAFO TEST systems automate testing on power transformers, distribution transformers and coils, and the INSULATION TEST series measures the loss factor (tan delta) on insulating materials.

Such equipment is used in metrology and high-voltage test laboratories, in transformer factories and in the laboratories of grid operators. If you have an existing EPRO transformer, or one with an earlier marking, the HVOT model or the series on the nameplate identifies the part.

What do we supply from the EPRO Gallspach range?

ProductDescription
Test transformers (HVOT)Step-up transformers for generating high voltage, from 20 kV to 600 kV and from 5 to 60 kVA continuous, in standard, dry-type or cascade design; examples: HVOT 200/10 KS, 300/20 KS, 500/25 KS, 500/30 KS.
Reference voltage transformersPassive standards for measuring and calibrating instrument transformers, from 50 V to 800/√3 kV, dry-insulated, in cast resin or in oil, with single-pole, two-pole and two-stage variants.
Reference current transformersCurrent standards, dry-insulated (1.1 kV) or oil-insulated (30–200 kV rated), for calibrations in metrology laboratories, with accuracy assured over the range 1–120% of the rated current.
TRAFO TEST and INSULATION TESTAutomatic measuring systems for transformers (variants for large and small transformers and for coils) and for insulating materials (variants with tan delta and endurance), with in-house inductive reference transformers.

Why EPRO Gallspach?

  • Test transformers from 20 to 600 kV — cascade models above 200 kV, with the lower stage usable independently
  • Passive, purely inductive reference transformers — no external supply and a service life of up to 30 years
  • Standards for calibrating other instrument transformers, in metrology laboratories
  • TRAFO TEST system with in-house inductive reference transformers — automatic testing on power transformers, distribution transformers and coils, extensible to a test centre
  • Custom design — the models are built to the customer's specification, not only in standard variants

Which EPRO Gallspach codes and series are requested most often?

CodeDescription
HVOT 200/10 KSOil-insulated test transformer, cascade, 200 kV, 10 kVA
HVOT 300/20 KSOil-insulated test transformer, cascade, 300 kV, 20 kVA
HVOT 500/25 KSOil-insulated test transformer, cascade, 500 kV, 25 kVA
HVOT 500/30 KSOil-insulated test transformer, cascade, 500 kV, 30 kVA
TRAFO TESTAutomatic test system for transformers and coils
INSULATION TESTMeasuring system for insulating materials

Where is EPRO Gallspach equipment used?

  • High-voltage laboratories — high-voltage tests, from 20 kV to 600 kV
  • Metrology institutes — reference transformers for calibrating other instruments
  • Manufacturers of instrument and power transformers — automatic test systems
  • Grid operators — in-house transformer verification laboratories
  • Research — measurements on insulation, tan delta and endurance tests

How do we supply EPRO Gallspach in Romania?

We can quote EPRO test transformers, reference transformers and measuring systems, as well as parts for existing EPRO equipment or equipment with an earlier marking. Supply is to order; as the products are made to the customer's specification, the lead time may be longer depending on the specification, including the configuration. For a correct quotation we need the voltage and power wanted, the working frequency, the design type (dry, oil, cascade), the accuracy class, the measuring range for reference transformers and the type of object tested. Accessories can ship in 24–72 h when the item is in stock, locally or at the supplier, and the exact lead time appears in the quotation.

The availability of a special design and the manufacturing lead time are established after the test specifications are checked.

Frequently asked questions about EPRO Gallspach

What products does EPRO Gallspach make?

Test transformers for high voltage (20–600 kV), reference voltage and current transformers, automatic systems for testing transformers (TRAFO TEST) and for measuring insulation (INSULATION TEST). The company was founded in 1994 at Gallspach, in Austria.

How do I choose a test transformer?

The starting point is the test voltage and the continuous power needed. Above 200 kV the cascade design is usually used; for low voltages and low weight there are dry-insulated variants, for 20 and 30 kV. The working frequency and the capacitive load of the object tested matter.

Can you supply EPRO equipment in Romania, and how soon?

Yes, they are supplied to order. EPRO transformers and systems are made to the customer's specification, so the lead time may be longer depending on the specification. Parts and accessories can ship in 24–72 h when the item is in stock, locally or at the supplier.

Can I replace an older reference transformer bearing an earlier marking with an EPRO one?

Equivalence is confirmed from the characteristics. We need the series, the transformation ratio, the class, the rated voltage and the design (dry or oil), to see which current model has close characteristics.

What data do I need to send for a reference transformer quotation?

The transformation ratio, the voltage or current range, the accuracy class required, the burden, the insulation type (dry, resin, oil), the number of poles and the standards according to which calibration is done.

How do I request a EPRO Gallspach quotation?

Send the EPRO Gallspach code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote