Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

ETS-Lindgren supplier in Romania

EMC test chambers, RF antennas and shielding systems

Founded in 1995 · Headquarters: Austin, Texas, USA

Request a quote

Who is ETS-Lindgren and what does it make?

ETS-Lindgren is an American maker of electromagnetic (EMC) test chambers, RF antennas and shielding systems, established in 1995, based in the Austin, Texas area. The range covers anechoic chambers from the FACT 3 family, antennas such as the 3104D Biconical or 3106B Double-Ridged Guide, RF absorbers from the DuraSorb (DSH) family and shielding systems for buildings or for medical equipment. From this range we can quote the antennas and RF absorbers frequently requested by EMC test laboratories in Romania.

What sets ETS-Lindgren apart is its complete coverage of the EMC test chain — from the anechoic chamber and the absorbers inside it, to the measurement antennas and software such as TILE! 8, an integrated environment for operating the EMC laboratory, or EMQuest, for antenna measurement. The multi-axis positioning systems from the MAPS family (for example 2112, 2117, 2122) automatically move the antenna or the device under test during the measurement, in line with the test standards. For critical environments such as medical MRI, the brand offers dedicated RF shielding components, such as the EVO doors for MRI rooms and the ClearShield windows.

For the Romanian market, ETS-Lindgren makes sense for EMC test laboratories for industrial and automotive equipment, for hospital MRI installations that need RF shielding, and for telecom operators who test the compliance of 5G equipment.

What do we supply from the ETS-Lindgren range?

ProductDescription
FACT 3 Series Anechoic ChambersFully equipped electromagnetic test chambers, used for emission and immunity measurements in line with EMC standards. They belong to the family of systems dedicated to 5G testing alongside the AMS-5700/5701/5702/5703 series, designed for characterising antennas at high frequencies and for over-the-air testing of wireless equipment.
Measurement Antennas (3102, 3104D, 3106B)A family of antennas for EMC testing and field measurements: 3102 Conical Log Spiral for wide band, 3104D Biconical for low frequencies, 3106B Double-Ridged Guide for higher frequencies. Selected according to the frequency band of interest and the test standard applied.
DuraSorb (DSH) Series RF AbsorbersHybrid absorbers for the walls and ceiling of anechoic chambers, available in the DSH-400H (low profile), DSH-600H and DSH-1250H (high performance) versions. The EHP High Performance version offers additional attenuation for strict test chamber requirements.
RF Shielding (EVO doors for MRI, ClearShield)Shielding solutions for environments sensitive to electromagnetic interference: EVO doors for magnetic resonance rooms and ClearShield shielded windows that keep visibility. They complete the architectural shielding offer for buildings or facilities with strict electromagnetic compatibility requirements.

Why ETS-Lindgren?

  • The range covers the EMC test chain — anechoic chamber, absorbers, antennas and analysis software
  • A range of hybrid RF absorbers (DuraSorb), in several versions, for different frequency bands
  • Multi-axis positioning systems (MAPS) for automating measurements in line with EMC standards
  • Dedicated RF shielding systems for medical environments (MRI) and for critical infrastructure

Which ETS-Lindgren codes and series are requested most often?

CodeDescription
3102 Conical Log Spiralwide-band antenna for EMC measurements
3104D Biconicalantenna for low frequencies
3106B Double-Ridged Guideantenna for high frequencies
FACT 3anechoic chamber for EMC testing
AMS-5700compact desktop 5G antenna measurement system (2D)
AMS-57015G antenna measurement system with theta arm (3D), mobile chamber type
AMS-5702MAPS-type 5G antenna measurement system (3D), mobile chamber
AMS-5703CATR-type 5G antenna measurement system, walk-in chamber
DSH-400HDuraSorb hybrid RF absorber, low profile
DSH-600HDuraSorb hybrid RF absorber
DSH-1250HDuraSorb hybrid RF absorber, high performance
EHP High Performancehigh-performance RF absorber
EVO Manual MRI DoorRF shielded door for MRI rooms, manually operated
ClearShield RF WindowsRF shielded window, transparent
TILE! 8integrated software for operating the EMC laboratory
EMQuestantenna measurement software
ProbeView IIsoftware for EM field probes
2112MAPS multi-axis positioning system
2117MAPS multi-axis positioning system
2122MAPS multi-axis positioning system

Where is ETS-Lindgren equipment used?

  • Aerospace and defence — EMC testing for critical equipment
  • Automotive — electromagnetic compatibility testing of components
  • Telecommunications and wireless — over-the-air testing for 5G equipment
  • Healthcare — RF shielding for magnetic resonance rooms
  • Utilities and critical infrastructure — protection against electromagnetic interference

How do we supply ETS-Lindgren in Romania?

ETS-Lindgren equipment is supplied to order, usually in 1–4 weeks. For a quotation we need the type of equipment (antenna, absorber, shielding system), the target frequency band and the test standard applied. Installation and qualification of the anechoic chamber remain the responsibility of the manufacturer or a specialised integrator.

We supply the components in the range; the design and installation of an anechoic chamber remain with an integrator.

Frequently asked questions about ETS-Lindgren

What products does ETS-Lindgren make?

ETS-Lindgren makes electromagnetic test chambers, RF antennas, absorbers and shielding systems, used for electromagnetic compatibility (EMC) testing of industrial, automotive, wireless and medical equipment, since 1995, based in Austin, Texas.

How do I choose an ETS-Lindgren antenna by model?

The choice depends on the frequency band to be measured: 3104D Biconical covers low frequencies, 3106B Double-Ridged Guide covers higher frequencies, and 3102 Conical Log Spiral offers wide-band coverage for preliminary scans.

What does the ETS-Lindgren range cover for EMC testing?

The range covers the whole EMC test chain: anechoic chambers, RF absorbers, measurement antennas and software for operating the laboratory and measuring antennas; the choice of component depends on the frequency band covered by each model and on the test standard specific to the project.

Can you supply ETS-Lindgren products in Romania and within what lead time?

Yes, to order; the lead time is usually 1–4 weeks, depending on the availability of the requested component, confirmed in the quotation.

What do I need to send for an ETS-Lindgren quotation?

The type of component wanted (antenna, absorber, shielding or positioning system), the frequency band of interest, the EMC test standard applicable to your project and the dimensions of the space available for installation.

How do I request a ETS-Lindgren quotation?

Send the ETS-Lindgren code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: ETS-Lindgren (manufacturer documentation)