Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Frankonia supplier in Romania

EMC test systems, EMI receivers, RF amplifiers, antennas and GTEM cells

Founded in 1987 · Headquarters: Heideck, Germany

Request a quote

Who is Frankonia and what does it make?

Frankonia (Frankonia Germany EMC Solutions GmbH) is a German manufacturer of electromagnetic compatibility test systems, based in Heideck, in Bavaria, active since 1987. The range covers conducted and radiated immunity test systems, EMI receivers for emission measurements, RF power amplifiers, broadband antennas and GTEM cells for testing in an enclosed chamber. From the Frankonia range we can quote both compact immunity systems for a single standard and individual components (amplifier, antenna, receiver) for a custom-built EMC laboratory.

What sets Frankonia apart is the organisation of the range directly around the test standards: the compact conducted immunity systems cover IEC/EN 61000-4-6 and 61000-4-16 as dedicated products, ready configured for that standard, while the radiated immunity systems answer IEC/EN 61000-4-3, ISO 11452-2 or the MIL-STD 461/RS103 family used in defence. The EMI receiver covers the 9kHz–6GHz range with FFT for emission measurements, and the RF amplifiers reach up to 18GHz and output powers of 12,000 W in the top versions. The ECU 3/6 control unit integrates the signal generator, relay switching, directional couplers, RF power meters and monitoring of the sample under test in a single unit.

For the Romanian market, Frankonia makes sense for EMC test laboratories, for manufacturers of automotive or industrial components who must demonstrate compliance with the EMC directive, and for institutes that test equipment for the defence field.

What do we supply from the Frankonia range?

ProductDescription
Compact conducted immunity systemsSystems dedicated to conducted immunity testing according to IEC/EN 61000-4-6 or IEC/EN 61000-4-16, with the signal generator, RF power amplifier and RF power meter integrated in a single frame. Designed for laboratories that run the same standard repeatedly, without assembling each component separately. Please state the exact test standard and the frequency range or power required for the sample under test.
Radiated immunity systemsSystems for radiated field immunity testing, compliant with IEC/EN 61000-4-3, ISO 11452-2 or the MIL-STD 461 family (including RS103), made up of an RF amplifier, an antenna and an electric field sensor. The configuration varies with the frequency range and the field strength required by the standard, from automotive tests to military tests. Typical application: EMC laboratories that test automotive electronic modules or defence equipment before certification.
EMI receivers and antennas for emission measurementEMI receiver with FFT for conducted and radiated emission measurements in the 9kHz–6GHz band, used together with a range of antennas that cover, overall, 9kHz–40GHz for the complete characterisation of a product before it is placed on the market. The set covers both pre-compliance during development and the final EMC certification tests. Please state the frequency range required and whether the test is for conducted emissions, radiated emissions or both.

Why Frankonia?

  • Conducted and radiated immunity systems organised directly around the test standard (IEC/EN 61000-4-x, MIL-STD 461)
  • RF amplifiers covering from direct current up to 18GHz, with output power of up to 12,000 W
  • EMI receiver with FFT for emissions, covering the 9kHz–6GHz band in a single instrument
  • ECU 3/6 control unit that integrates the generator, relay switching and monitoring of the sample
  • Portfolio that includes the GTEM cell, antennas, EMI receivers and RF amplifiers

Which Frankonia codes and series are requested most often?

CodeDescription
IEC/EN 61000-4-6 SystemCompact radio-frequency conducted immunity system
IEC/EN 61000-4-16 SystemCompact low-frequency disturbance immunity system
IEC/EN 61000-4-3 SystemRadiated immunity system according to the EMC standard
ISO 11452-2 SystemRadiated immunity system for automotive
MIL-STD-461 RS103 SystemRadiated immunity system for military equipment
EMI-Receiver 9kHz-6GHzEMI receiver with FFT for emission measurements
RF-Power-AmplifierRF power amplifier, up to 18GHz
ECU 3/6Integrated EMC control unit
GTEM-CellGTEM cell for EMC testing in an enclosed space
E-field SensorElectric field sensor, battery- or laser-powered
Magnetic-field Test SystemMagnetic field test system, up to 1000A/m
Antenna 9kHz-40GHzRange of antennas for EMC measurements (9kHz–40GHz overall)

Where is Frankonia equipment used?

  • Automotive — immunity testing of electronic components according to automotive standards
  • Defence — immunity tests according to the MIL-STD 461 family
  • Industrial — verification of EMC compliance for industrial equipment
  • Test laboratories — equipment and components for EMC laboratories

How do we supply Frankonia in Romania?

We work from the Frankonia data sheets for the exact configuration of each system. We supply Frankonia systems and components to order, usually 1–4 weeks depending on the complexity of the configuration. For a quotation, please send the test standard concerned (for example IEC/EN 61000-4-3), the frequency range and the power or field strength required. This range is supplied to order; each EMC system is configured for the customer's laboratory.

The availability of the ProveEMC software for Romania is checked on request, and the installation and commissioning of a complete EMC laboratory remain with an integrator.

Frequently asked questions about Frankonia

What products does Frankonia make?

Frankonia makes electromagnetic compatibility test systems: conducted and radiated immunity systems, EMI receivers, RF amplifiers, antennas and GTEM cells. The company is based in Heideck, Germany, and has been active in EMC testing since 1987.

How do I choose a Frankonia system for a specific immunity standard?

The choice starts from the standard required by the customer or by the certification body — IEC/EN 61000-4-6 for conducted radio-frequency immunity, IEC/EN 61000-4-3 for radiated immunity, or the MIL-STD 461 family for military equipment. Frankonia offers compact systems dedicated to each standard.

What frequency range does the Frankonia EMI receiver cover?

The Frankonia EMI receiver covers the 9kHz–6GHz band with an FFT function for emissions; the final choice depends on the certification standard and on the laboratory's accuracy budget.

What lead time do you offer in Romania for Frankonia equipment?

We supply Frankonia systems to order, usually 1–4 weeks, depending on the complexity of the EMC configuration requested. This range is supplied to order.

How do I request a Frankonia quotation?

Send the Frankonia code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: Frankonia Germany EMC Solutions GmbH (manufacturer documentation)