ERLPhase supplier in Romania
Disturbance recorders and protection relays for electrical substations
Founded in 1993 · Headquarters: Winnipeg, Canada
Who is ERLPhase and what does it make?
ERLPhase Power Technologies is a Canadian manufacturer based in Winnipeg. The story begins in 1993, when a development team with roots at the University of Manitoba created, under the name APT Power Technologies, a protection relay for transformers. Today it makes two things: disturbance recorders for power systems (the TESLA series) and multifunction numerical protection relays (L-PRO, T-PRO, B-PRO, F-PRO, M-PRO). The quality management system is certified according to the manufacturer's documentation, and the relays are tested on an automated test bench at the Winnipeg facility.
The problem it solves is one that every substation engineer knows: after a fault on a line or a transformer, what happened in the milliseconds before and after the trip has to be reconstructed. The TESLA recorders write fast (fault), slow (swing) and trend records simultaneously, have over 1000 user-definable triggers and work with GOOSE messages from IEC 61850. The 4000 model can also transmit synchronised phasors (PMU), and the 4000-SV version reads streams of sampled values from merging units. The L-PRO relay handles transmission lines with five distance zones and two breakers, T-PRO protects multi-winding transformers and reactors, and B-PRO covers busbars with up to six bays.
Such equipment is used in 110–400 kV substations, in protection and fault recorder retrofits and in the move towards digital substations according to IEC 61850. The range is also of interest to industry with its own medium-voltage supply, where the F-PRO and M-PRO relays protect feeders and large motors.
What do we supply from the ERLPhase range?
| Product | Description |
|---|---|
| TESLA 4000 (Model 4000, 4000-A, 4000-SV) | Disturbance recorder with CDR, PMU and IEC 61850 protocols. It writes fast, slow and trend records simultaneously, has over 1000 triggers and 256 virtual inputs for GOOSE messages. The SV version adds sampled value streams and MMS reporting to remote clients. |
| TESLA LITE | Multi-domain recorder for smaller substations: 12 current inputs, 6 voltage inputs and 38 digital inputs, IRIG-B synchronisation, fault location from currents and a small footprint, useful for retrofits in cabinets with limited space. |
| L-PRO 4000 / 4500 | Numerical distance protection relay for lines from medium to extra-high voltage: five phase and ground zones, single-pole and three-pole reclosing with four attempts, control for two breakers, fault recording. The 4500 version has 1 A and 5 A CT inputs and, optionally, redundant PRP communication. |
| T-PRO 4000 / 4500 / 2000 | Protection for three-phase multi-winding transformers and reactors: differential, overcurrent, neutral overvoltage, frequency, overexcitation, plus monitoring of through faults (duration, peak, I²t values). The same oscillography and event log as in the rest of the family. |
Why ERLPhase?
- Three time domains recorded simultaneously — TESLA 4000 writes fault, swing and trend records, with over 1000 user-definable triggers, so a rare event does not depend on the threshold of a single relay
- PMU built into the recorder — the 4000 model transmits synchronised phasors for wide-area monitoring, without a separate device
- Digital substations — the 4000-SV version subscribes to Sampled Values (IEC 61850-9-2 LE and IEC 61869-9) and to GOOSE messages, which matters when retrofitting towards substations without conventional secondary circuits
- Two cases for the same software — L-PRO and T-PRO come in a 19 inch rack version (4000) or in an E12 case with dual 1 A and 5 A CT inputs (4500), with the same user software
- L-PRO line relay with five distance zones for phase and ground — protection and control for two breakers, suited to ring bus or breaker-and-a-half schemes
Which ERLPhase codes and series are requested most often?
| Code | Description |
|---|---|
| TESLA 4000 (Model 4000) | Disturbance recorder with CDR, PMU and IEC 61850 |
| TESLA 4000 (Model 4000-A) | Variant of the TESLA 4000 recorder |
| TESLA 4000 (Model 4000-SV) | Recorder for digital substations, with IEC 61850-9-2 LE and IEC 61869-9 |
| TESLA 4000 Portable | Portable variant of the TESLA 4000 recorder |
| TESLA LITE | Compact recorder: 12 current, 6 voltage, 38 digital |
| I/O Expansion | Stand-alone module: 128 digital inputs, 15 output contacts, GOOSE |
| L-PRO 4000 | Line protection, 19 inch rack case |
| L-PRO 4500 | Line protection, E12 case, 1 A and 5 A CT inputs |
| T-PRO 4000 | Transformer protection, 19 inch rack |
| T-PRO 4500 | Transformer protection, E12 case, optional PRP |
| T-PRO 2000 | Transformer protection from the T-PRO family |
| B-PRO 4000 | Busbar protection, up to 6 bays; multi-bus scheme up to 24 |
| F-PRO 4500 | Feeder protection and management |
| F-PRO 216 / 235 | Feeder relays from the F-PRO family |
| M-PRO 2000 | Numerical motor protection with current and voltage inputs |
| S-PRO 4000 | Subharmonic protection relay |
Where is ERLPhase equipment used?
- 110–400 kV substations — fault recording and protection of lines and transformers
- Power transmission — wide-area monitoring with synchronised phasors
- Substation retrofits — moving to IEC 61850 with GOOSE and Sampled Values
- Industry with its own medium-voltage network — protection of feeders and large motors
- Power plants — analysis of network events after trips
How do we supply ERLPhase in Romania?
We can quote TESLA recorders, numerical relays from the L-PRO, T-PRO, B-PRO, F-PRO and M-PRO families, I/O expansion modules and test accessories, in the configuration confirmed in the quotation. The equipment is supplied to order, typically in 1–4 weeks; for configured or complex systems the lead time may be longer. For a correct quotation, send the model or the code from the nameplate, the number of analogue and digital inputs, the rated voltage and current of the circuits measured and the communication protocol wanted, for example IEC 61850. The exact lead time is confirmed in the quotation.
The firmware version and the licence package for a specific configuration are confirmed after the request has been reviewed.
Frequently asked questions about ERLPhase
What does ERLPhase make?
In Winnipeg, ERLPhase makes disturbance recorders for power networks (the TESLA series) and multifunction numerical relays for lines, transformers, busbars, feeders and motors. Both families can work with IEC 61850, which makes them useful in new or retrofitted substations.
How do I choose between TESLA 4000 and TESLA LITE?
TESLA LITE has 12 current inputs, 6 voltage inputs and 38 digital inputs, so it suits a smaller substation or a retrofit with little space. TESLA 4000 is chosen when PMU, GOOSE messages and, in the SV version, sampled values are required. Tell us the number of circuits measured and the protocols required.
Can you supply ERLPhase equipment in Romania, and within what lead time?
Yes, we supply it to order. The lead time to order is typically 1–4 weeks, but for configured recorders or systems with several modules it may be longer; we confirm it in the quotation, once we know the model and the options.
Can I replace an existing line relay with an L-PRO 4500?
It depends on the existing case and terminals. L-PRO 4500 has an E12 case, dual 1 A and 5 A CT inputs and, optionally, PRP, while the 4000 is a 19 inch rack. We confirm equivalence on the basis of data: send the current relay, the single-line diagram and the line voltage, and we check the compatibility.
What information do you need for a quotation on a TESLA recorder?
The number of analogue inputs (current and voltage), the digital inputs, whether you need PMU, GOOSE or sampled values, the synchronisation source (for example IRIG-B) and the space available in the cabinet. With these data we determine the model and the expansion modules before the quotation.
How do I request a ERLPhase quotation?
Send the ERLPhase code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: ERLPhase Power Technologies Ltd. (manufacturer documentation)