Cooling towers and evaporative condensers for industry

Headquarters: Taneytown, USA

Request a quote

Who is EVAPCO and what does it make?

EVAPCO is an American manufacturer of cooling towers, evaporative condensers and closed-circuit coolers, headquartered in Taneytown, Maryland. The range covers induced-draft cooling towers of the AT series, the AT Atlas model with certified capacity per cell, centrifugal fan towers of the LSTE and LPT series for indoor installation or limited space, as well as eco-ATWB-H closed-circuit cooling systems. For the Romanian market we can quote from the range of cooling towers and closed-circuit coolers for industrial and HVAC installations.

What distinguishes EVAPCO is the variety of configurations for the same evaporative cooling principle: induced-draft towers with axial fan (AT series) for high outdoor capacities, centrifugal fan towers with low profile (LSTE, LPT) for indoor installations or those with height restrictions, and the advanced AXS crossflow configuration. The eco-Air series, with dry and adiabatic solutions, comes with a thermal performance warranty.

For customers in Romania, EVAPCO makes sense at power plants, industrial process cooling installations and data centres where a CTI-certified cooling capacity and flexible installation options are required — from large outdoor towers to compact units for indoor spaces with limited height.

What do we supply from the EVAPCO range?

ProductDescription
AT series induced-draft cooling towersCooling towers with axial fan and induced draft, for a wide range of outdoor cooling capacities, with the AT Atlas model as an energy-efficient modular variant, with high CTI-certified capacity per cell. The series also includes the SUN model, a more recent variant with a counterflow configuration. They are used at power plants, industrial process installations and high-capacity HVAC systems.
LSTE/LPT series centrifugal fan towersForced-draft cooling towers with centrifugal fan and low profile, suited to indoor installation, to locations with air ducts (ducted) or to spaces with limited height. Both LPT and LSTE suit such locations; the right model is confirmed on the basis of the space restrictions and the thermal load.
eco-ATWB-H closed-circuit coolersClosed-circuit coolers that combine evaporative cooling with isolation of the process fluid from the outside environment, avoiding direct contamination of the cooled fluid. They are used where the process fluid must be protected from impurities or from contact with outside air, unlike open cooling towers. They complete the EVAPCO range for industrial applications where the purity of the cooling fluid matters as much as thermal efficiency.

Why EVAPCO?

  • CTI-certified capacity per cell on the AT series towers, verifiable independently of the manufacturer
  • Centrifugal fan towers with low profile, for indoor installation or with space restrictions
  • Own water treatment systems (Pass-Protect, Water Saver) that can be integrated with the cooling towers
  • Advanced AXS crossflow configuration for induced draft with axial fan
  • Range from cooling towers to closed-circuit coolers

Which EVAPCO codes and series are requested most often?

CodeDescription
ATinduced-draft cooling tower, axial fan
AT Atlasmodular cooling tower, high CTI capacity per cell
SUNcounterflow cooling tower, more recent variant of the AT series
LSTEcentrifugal fan cooling tower, low profile
LPTcooling tower with centrifugal fan, low profile
AXScrossflow cooling tower, axial induced draft
eco-Airdry/adiabatic cooling system with thermal performance warranty
eco-ATWB-Hevaporative closed-circuit cooler
VersaSplitsystem from the EVAPCO range; details confirmed from the manufacturer's documentation
Pass-Protectpassivation solution for water treatment
Water Saversystem for reducing water consumption at cooling towers

Where is EVAPCO equipment used?

  • Commercial HVAC — cooling for large buildings and shopping centres
  • Industrial refrigeration — cooling for ammonia processes
  • Power generation — turbine condenser cooling
  • Industrial processing — process fluid cooling
  • Data centres — cooling of high-density IT equipment

How do we supply EVAPCO in Romania?

For EVAPCO we rely on the manufacturer's technical documentation; we state lead time and availability in the quotation. We bring cooling towers, evaporative condensers and closed-circuit coolers to order, typically in 1–4 weeks from the manufacturer's confirmation of the configuration. For a quotation we need the thermal capacity required, the space available at the site (indoor or outdoor) and any noise or height restrictions. Equipment sized individually per project is built to order.

Lead times for high-capacity factory-assembled units are set through a technical request.

Frequently asked questions about EVAPCO

What products does EVAPCO make?

EVAPCO makes cooling towers, evaporative condensers and closed-circuit coolers for industrial HVAC, refrigeration and power generation, with headquarters in the United States, at Taneytown.

How do I choose the right EVAPCO cooling tower for my installation?

The choice depends on the thermal capacity required and the space available: AT series towers are for high-capacity outdoor installation, while LSTE and LPT are for indoor or limited-height spaces. Send us the thermal load and the site wanted.

Can you supply EVAPCO equipment in Romania and in what lead time?

Yes, we bring EVAPCO cooling towers and coolers to order, typically in 1–4 weeks, depending on the configuration confirmed by the manufacturer.

What data do you need for an EVAPCO cooling tower quotation?

You need the thermal capacity required, the water inlet and outlet temperatures, the space available at the site and whether the installation is indoor or outdoor, plus any noise restrictions allowed at the site.

How do I request a EVAPCO quotation?

Send the EVAPCO code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: EVAPCO, Inc. (manufacturer documentation)