Gräff supplier in Romania

For Gräff we quote GF-70xx series thermocouples, GF-71xx resistance thermometers, DA, DAI, DTA and DTAI melt pressure sensors, electric heating elements and insulating jackets; we need the series, the temperature and the mounting parameters.

Headquarters: Troisdorf, Germany

Request a quote

Who is Gräff and what does it make?

Gräff GmbH in Troisdorf works in four areas: temperature sensors, melt pressure sensors, electric heating technology and insulating jackets, plus electronics. The core of the range is measuring temperature and pressure in processes with molten material and electrically heating machine elements.

The temperature sensors are divided into thermocouples and resistance thermometers, each with dozens of series codes. The GF-70xx, GF-80xx and GF-9000 thermocouples come in types Fe-CuNi/L, Fe-CuNi/J and NiCr-Ni/K, according to DIN EN 60584, with a range up to +1200 °C. The GF-71xx, GF-81xx and GF-9100 resistance thermometers use Pt50, Pt100, Pt500 or Pt1000 in a 2, 3 or 4-wire circuit, with a range up to +600 °C, according to DIN 60751.

The melt pressure sensors of the DA, DAI, DTA and DTAI series cover pressures up to 2000 bar, have an all-stainless-steel housing and are thermally compensated, with output in mV/V, mA or V. The DTA and DTAI series add a temperature sensor. The heating range includes nozzle band heaters, ceramic band heaters, cartridges, tubular and threaded heaters, flat heaters and electrically heated fans.

The company can adapt or redesign any heating element to the customer's requirement, including for narrow installations or those with a complicated structure, and offers suitable accessories for all the elements listed. For a correct order the series, dimensions and voltage matter for the heating elements, and for the sensors the series, length and output type.

What do we supply from the Gräff range?

ProductDescription
Thermocouples GF-70xx, GF-80xxFe-CuNi/L, Fe-CuNi/J and NiCr-Ni/K thermocouples according to DIN EN 60584, with accuracy better than 1.5 K, welded or galvanically isolated, for temperatures up to +1200 °C. They have thermocouple cable and dozens of mounting designs.
Resistance thermometers GF-71xx, GF-81xxPt50, Pt100, Pt500 and Pt1000 resistance thermometers according to DIN 60751, with 2, 3 or 4-wire circuit, vibration- and shock-resistant versions and a range up to +600 °C. The connecting cable is copper or nickel.
Melt pressure sensors DA, DAI, DTA, DTAISensors for melts, with pressures up to 2000 bar, accuracy classes of 0.15 %, 0.25 % and 0.50 %. The output is in mV/V (DA, DTA) or in mA or V (DAI, DTAI), and DTA and DTAI include a temperature sensor.
Electric heating elementsDHB nozzle band heaters, DHB/K and KHB ceramic band heaters, ZHB cylindrical band heaters, KHK box-type band heaters, HLP-HP/S cartridges, RHK tubular heaters, EHK threaded heaters, FHK flat heaters and ELT electrically heated fans.

Why Gräff?

  • Dozens of series codes for thermocouples and resistance thermometers, GF-70xx and GF-71xx — a design can be chosen exactly by mounting and length
  • Melt pressure sensors up to 2000 bar, with stainless steel housing — pressure is measured directly in the melt
  • Versions with output in mV/V, mA or V, and on DTA and DTAI with a temperature sensor included — a single measuring point for pressure and temperature
  • Pt100 and Pt1000 resistance thermometers, with 2, 3 or 4 wires — the circuit matches the input of the existing controller
  • Heating elements and insulating jackets from the same family — heating and measurement are ordered from the same range

Which Gräff codes and series are requested most often?

CodeDescription
GF-7003Thermocouple, series from the GF-70xx family
GF-7020/WThermocouple, version from the GF-70xx family
GF-7031Thermocouple, series from the GF-70xx family
GF-8000Thermocouple, series from the GF-80xx family
GF-9000Thermocouple, measuring insert with connection base
GF-7103Resistance thermometer, series from the GF-71xx family
GF-7131Resistance thermometer, series from the GF-71xx family
GF-8100Resistance thermometer, series from the GF-81xx family
GF-9100Resistance thermometer, measuring insert with connection base
DAMelt pressure sensor, mV/V output
DAIMelt pressure sensor, mA or V output
DTAMelt pressure sensor with temperature sensor, mV/V output
DTAIMelt pressure sensor with temperature sensor, mA or V output
RHKTubular heater
HLP-HP/SCartridge heater

Where is Gräff equipment used?

  • Processes with molten material — melt pressure and temperature measured with the DA, DAI, DTA and DTAI sensors
  • Installations with heated zones — thermocouples and resistance thermometers for temperature control
  • Thermal installations — electric heating elements for nozzles, barrels and flat surfaces
  • Machine building — temperature sensors with cable for special measuring points

How do we supply Gräff in Romania?

We can quote Gräff thermocouples and resistance thermometers, DA, DAI, DTA and DTAI melt pressure sensors and electric heating elements, depending on the series requested. We need the series code, the sensor type, the length, the temperature or pressure range and the output signal you want. For heating elements add the dimensions and the voltage. We supply to order, usually in 1–4 weeks, and the exact date appears in the quotation.

The nominal pressure and the rod length are confirmed in the quotation, once you tell us which melt you measure and at what temperature.

Frequently asked questions about Gräff

What does Gräff make?

Gräff in Troisdorf makes temperature sensors, that is thermocouples and resistance thermometers, melt pressure sensors, electric heating elements, insulating jackets and electronic components. The range serves processes with molten material and machines with heated zones.

How do I choose between the DA, DAI, DTA and DTAI series?

Choose by the output signal and by the need for temperature. DA and DTA output in mV/V, DAI and DTAI in mA or V, and DTA and DTAI add a temperature sensor. Send the maximum pressure, the signal the controller accepts and the mounting thread.

Do you supply Gräff sensors in Romania and how fast?

Yes, Gräff sensors are ordered and usually arrive in 1–4 weeks. An item can ship in 24–72 h when the item is in stock, locally or at the supplier. Special series can take longer.

Can I replace a GF thermocouple or resistance thermometer with another code?

Yes, if the type, length, cable and sensor end match. Send the GF code from the label, the photo and the dimensions, and we determine which series fits before the quotation.

What should I send for a DTA or DTAI melt pressure sensor?

Send the series you want, the maximum pressure, the accuracy class, the output signal, the melt temperature and the mounting thread. If you are replacing an old sensor, add the code on the body or a photo. From these we select the series and the output version. DTA and DTAI are melt pressure sensors with a temperature sensor, with output in mV/V, and in mA or V respectively.

How do I request a Gräff quotation?

Send the Gräff code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Gräff GmbH (manufacturer documentation)