Graviner supplier in Romania
For Graviner we offer Mk7 detectors 1-53836-K269, K270 and K276 control units, the K271 display unit and K285 and K286 connecting cables; we need the engine type, the number of crankcase compartments and the codes of the existing components.
Who is Graviner and what does it make?
Graviner Mk7 is an oil mist detection system for diesel engine crankcases. The problem it solves is one of safety: a bearing that overheats above 200 °C vaporises the oil, and the vapours condense in the cooler crankcase as a mist, with droplets of 0.5–5 microns. At a density of 30–50 mg/l, depending on the oil type, the mist reaches the lower explosion limit, and a hot spot or a foreign body is enough for ignition. Mk7 detectors measure the density optically, by light scattering, starting from 0.05 mg/l, so they signal the rise well before the dangerous threshold.
The system works without sampling pipes. Each detector is mounted directly on the crankcase and monitors a single compartment; addressing is automatic, and a faulty detector can be isolated without affecting the others. A control unit mounted on the engine polls up to 10 detectors, and a system can include up to 10 units, i.e. 100 detectors for 10 engines, main and auxiliary. The control unit has three alarms with volt-free contacts: pre-alarm, slowdown or shutdown alarm, and a backup alarm with a fixed threshold of 3.0 mg/l. A 7.5-inch colour touchscreen, mounted in the engine control room, shows the level for each engine and detector.
The system applies to two-stroke and four-stroke engines and is approved to IACS M67/M10 (rules of the International Association of Classification Societies) by several marine classification societies, according to the manufacturer's documentation. The IACS rules require oil mist detection if the engine bore exceeds 300 mm, the power exceeds 2,200 kW or the engine room is normally unattended. For a shipowner, a repair yard or an operator of large diesel generator sets, the quotation starts from the code on the detector or control unit and from the engine type, because variants and cable lengths differ from one installation to another.
What do we supply from the Graviner range?
| Product | Description |
|---|---|
| Mk7 Detector (1-53836-K269) | Smart stand-alone detector, mounted on one crankcase compartment, with IP65 housing, ¾ inch BSP mounting thread, 1.5 W consumption and an operating temperature of 0–70 °C. It transmits the mist density value digitally to the control unit. There is a variant with a short sampling tube (-01) and the replacement head 1-53836-K272. |
| Control Unit (1-53836-K270 / 1-53836-K276) | Engine-mounted unit in an IP65 aluminium housing, which polls up to 10 detectors. It is supplied with a membrane keypad, with status LEDs and buttons for accepting, resetting and isolating detectors (K270), or without a membrane keypad (K276). 24 V DC supply, three sets of alarm relays and a fault relay. |
| Remote Display Unit (1-53836-K271) | 7.5-inch colour LCD touchscreen for the engine control room, in wall or panel variants. It shows the mist level for each engine and, on request, for each detector, the system status and the event log. Alarm thresholds are set from here or from a PC connected to the control unit. |
| Cables, kits and software (1-43682-K285 / K286, 1-53836-K279) | The cables between the detector and the control unit are available with a 90° angled connector (K285) or a straight one (K286), in lengths from 1 m to 25 m. The Oil Mist Manager software (K279), the commissioning and service kits and the Mk5–Mk7 upgrade board (1-35100-K274) complete the installation. |
Why Graviner?
- No sampling pipes — the detectors are mounted directly on the crankcase, and each one analyses locally the optical density of the mist in its compartment
- Automatic addressing — up to 10 detectors per control unit and up to 10 units per system, which reduces configuration errors at installation
- Three independent alarms — pre-alarm, slowdown or shutdown and backup alarm, each with volt-free contacts for beacons or engine circuits
- 24-hour self-test — each detector checks itself, and faults go into the event log with 1024 entries
- IACS M67/M10 approval — the system is tested and approved by marine classification societies, a requirement at acceptance of many installations with large engines
Which Graviner codes and series are requested most often?
| Code | Description |
|---|---|
| 1-53836-K269 | Complete Mk7 detector, with base |
| 1-53836-K269-01 | Complete Mk7 detector, with short sampling tube |
| 1-53836-K272 | Detector head, replacement assembly |
| 1-53836-K270 | Control unit with membrane keypad, for 10 detectors |
| 1-53836-K270-01 | Control unit with membrane keypad, variant for Caterpillar engines |
| 1-53836-K276 | Control unit without membrane keypad, for 10 detectors |
| 1-53836-K271 | Remote display unit, colour touchscreen |
| 1-43682-K285-XX | Detector–control unit cable, 90° angled connector |
| 1-43682-K286-XX | Detector–control unit cable, straight connector |
| 1-53836-K279 | Oil Mist Manager software |
| 1-35100-K274 | Mk5–Mk7 upgrade board |
| 1-D9221-026 | Commissioning kit |
| 1-D9221-027 | Service kit |
Where is Graviner equipment used?
- Maritime transport — crankcase monitoring on main propulsion engines and auxiliary generators
- Ship repair yards — upgrading older oil mist detection installations
- Power generation — high-power diesel generator sets with separate control rooms
- Industrial two-stroke and four-stroke diesel engines — crankcase explosion protection
How do we supply Graviner in Romania?
We can quote Graviner Mk7 detectors, control units, display units, cables and spare parts, starting from the codes of the form 1-53836-K on the existing components. We supply to order, usually in 1–4 weeks; depending on the specification, the lead time can be longer. For an accurate quotation, send us the engine type and the number of crankcase compartments, the codes of the installed components, the cable length between the detector and the control unit, the supply voltage and the classification society approving the installation. The exact lead time is confirmed in the quotation.
The number of detectors and the cable lengths are set from the crankcase sketch and the position of the control unit on the engine.
Frequently asked questions about Graviner
What is the Graviner Mk7 system and what does it protect?
Graviner Mk7 is an oil mist detection system for the crankcases of two-stroke and four-stroke diesel engines. The detectors measure the mist density optically, starting from 0.05 mg/l, and raise the alarm before the oil reaches the explosion limit, so the engine can be stopped once an overheated bearing has appeared.
How many Mk7 detectors are needed for one engine?
A detector monitors a single crankcase compartment, so their number equals the number of compartments. A control unit accepts up to 10 detectors, and a system can have 10 units, i.e. 100 detectors for 10 engines. Send us the engine type and the number of compartments.
Can Graviner components be supplied in Romania and how quickly?
Yes, we supply to order, usually in 1–4 weeks. An item can ship in 24–72 h when the item is in stock, locally or at the supplier. Depending on the specification, the lead time can be longer; we confirm it in the quotation for Graviner items.
Can older installations still be upgraded with Mk7 detectors?
For moving from the Mk5 system to Mk7 there is the upgrade board with the code 1-35100-K274. Compatibility is checked from the codes on the existing components, the engine type and photos of the installation, and then we confirm what can be kept.
What data should I send for a Mk7 system quotation?
Send the engine type and number, the number of crankcase compartments per engine, the 1-53836-K codes on the existing components, the cable length needed between the detector and the control unit, the supply voltage available and the classification society approving the installation. With this data we prepare the quotation.
How do I request a Graviner quotation?
Send the Graviner code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Fire Security Products (manufacturer documentation)