Grundfos Grundfos MTH

Grundfos MTH multistage immersible centrifugal pumps, mounted on the tank cover, for coolants and lubricants on machine tools: sizes MTH 2, 4, 8, 10 and 15, rated flow 2.5–18 m³/h at 50 Hz and motors of 0.55–4 kW.

Grundfos MTH is a range of vertical, multistage, immersible centrifugal pumps designed for pumping coolants and lubricants on machine tools, for condensate transfer and similar applications. The pump is mounted on the tank cover, with the chamber stack submerged in the liquid; the immersed length is adapted to the tank by means of empty chambers. The Grundfos data booklet lists it for drilling, milling, grinding, electrical discharge machining, wire cutting, turning, cooling (chillers), parts washing, filtration, condensate systems and washing-cleaning. The range has two material versions: A, with a cast iron EN-GJL-200 pump head, and I, with a stainless steel 1.4408 head; the motor is a standard Grundfos MG motor, 2-pole, totally enclosed and fan-cooled. For variable speed there is the MTHE variant, with an integrated frequency converter.

For a quotation, send us the full code from the nameplate; the example in the data booklet is MTHE 2-6/3 A-W-A-AQQV: after MTH come the size, the number of chambers and the number of impellers, then the codes for version, connection, materials and shaft seal. If the nameplate is missing, send us the required flow and pressure, the pumped liquid, the tank depth, the supply voltage and the frequency (50 or 60 Hz).

Models and codes

CodeNote
MTH 2-3/33 chambers, 3 impellers, 0.55 kW motor (50 Hz); MEI index > 0.70.
MTH 2-6/36 chambers, of which 3 with impeller, 0.55 kW motor (50 Hz).
MTH 4-9/99 chambers, 9 impellers, 2.2 kW motor (50 Hz); size MTH 4 has a rated flow of 4 m³/h.
MTH 8-8/88 chambers, 8 impellers, 3 kW motor (50 Hz); size MTH 8 has a rated flow of 8 m³/h.
MTH 10-1/1one chamber, one impeller, 1.1 kW motor (50 Hz); size MTH 10 has a rated flow of 12 m³/h.
MTH 10-6/66 chambers, 6 impellers, 4 kW motor (50 Hz).
MTH 15-6/46 chambers, of which 4 with impeller, 4 kW motor (50 Hz); size MTH 15 has a rated flow of 18 m³/h.

Key specifications

Rated flow at 50 Hz (MTH 2 / 4 / 8 / 10 / 15)2.5 / 4 / 8 / 12 / 18 m³/h
Flow range at 50 Hz (same sizes)0.7–3.5 / 1.2–8 / 4–12 / 5–15 / 6–22 m³/h
Maximum head at 50 Hz, expressed in bar (same sizes)10 / 10 / 8 / 10 / 7 bar
Motor power at 50 Hz (same sizes)0.55–1.1 / 0.55–2.2 / 0.55–3 / 1.1–4 / 1.1–4 kW
Liquid temperature-10…+90 °C
MotorGrundfos MG, 2-pole, IP54, insulation class F; IE3 efficiency class for the 50 Hz MTH motors; standard voltage at 50 Hz: 220–240 V Δ / 380–415 V Y
Connection (MTH 2, 4, 8 / MTH 10, 15)version A: Rp 3/4 / counter flange G 1 1/4; version I: Rp 3/4 / Rp 1 1/4 or G 1 1/4
Shaft sealAQQV (O-ring seal with fixed driver, silicon carbide / silicon carbide, FKM), -10…+90 °C; other seals on request
Passage through the suction strainer (MTH 2 / MTH 4, 8, 10, 15)Ø 2 / Ø 4 mm

The data come from the Grundfos data booklet “MTR, MTRE, SPK, MTH, MTHE, MTA Immersible pumps 50/60 Hz” (code 96538374, ECM 1399187, edition 07.2024, 223 pages), published on the official Grundfos documentation server. The booklet covers several ranges together; only the data for MTH at 50 Hz are used, and the exact variant is confirmed on the full code from the nameplate.

Frequently asked questions

How do I read an MTH code, for example MTH 2-6/3?

According to the Grundfos data booklet, MTH is followed by the pump size (2), the number of chambers (6) and the number of impellers (3); the letter E after MTH indicates an integrated frequency converter (MTHE). The group after the code, for example A-W-A-AQQV, describes the version, the connection, the materials and the shaft seal.

What liquids can an MTH pump handle?

The data booklet lists non-explosive liquids that do not chemically attack the pump materials; at a density or viscosity higher than that of water, an oversized motor may be needed. The suction strainer has Ø 2 mm holes on MTH 2 and Ø 4 mm holes on the other sizes; wear of the components by abrasive particles starts above a concentration of 20 ppm.

How is the pump mounted in the tank?

MTH pumps are mounted vertically. The distance between the flange and the liquid level and the distance between the pump and the tank bottom are at least 25 mm each. A priming screw fitted under the bottom chamber allows a low liquid level, 40 mm above the bottom of the strainer, and protects the pump against dry running down to 25 mm above the bottom of the strainer.

Other Grundfos series

The immersed length, the connection and the shaft seal differ from one variant to another; we confirm the exact variant before the quotation, on the full code from the nameplate or on the tank depth and the duty point.

Updated: 2026-11-23