Grundfos Grundfos UPS / UPSD Series 200
Grundfos UPS (single) and UPSD (twin) Series 200 wet-rotor circulator pumps, with three speed steps, for heating and air conditioning (bronze variants and variants for domestic hot water), with flanged connections of 32–100 mm.
UPS and UPSD are Grundfos wet-rotor circulator pumps (no shaft seal), with a three-speed-step motor, intended for circulating liquids in heating and air conditioning installations; the variants with a bronze body are also suitable for domestic hot water. UPS is the single-head variant, UPSD the twin-head variant. The datasheet covers flanged connections from 32 mm to 100 mm, in single-phase (1 × 230–240 V) or three-phase (3 × 400–415 V) design, and in the code the value after the diameter is the maximum head in dm: UPS 40-180 F 250 means a 40 mm connection, a maximum head of 18 m and a port-to-port length of 250 mm.
For a quotation, send us the complete code from the nameplate (for example UPS 40-180 F 250) or the product number, the supply voltage, the pressure rating (PN 6 or PN 10), the body material (cast iron or bronze) and, for the UPSD variants, the type of terminal box module. When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.
Models and codes
| Code | Note |
|---|---|
| UPS 32-60 F 220 | 32 mm connection, single, cast iron, 1 × 230–240 V, PN 6/PN 10; product number 96401771; maximum power 190 W at step 3. |
| UPS 40-180 F 250 | 40 mm connection, single, cast iron, 1 × 230–240 V, PN 6/PN 10; product number 96401977; maximum power 790 W at step 3, net weight 23.7 kg. |
| UPS 40-180 F B 250 | Same size with bronze body, 1 × 230–240 V; product number 96401983; net weight 26.5 kg. |
| UPS 50-120 F 280 | 50 mm connection, single, cast iron, 1 × 230–240 V; product number 96402101. |
| UPS 65-120 F 340 | 65 mm connection, single, cast iron, 1 × 230–240 V; product number 96402278; maximum power 1,200 W at step 3, net weight 29.7 kg. |
| UPS 100-30 F 450 | 100 mm connection, single, cast iron, only 3 × 400–415 V; product number 96402503 for PN 6 (96402508 for PN 10). |
| UPSD 50-120 F 280 | 50 mm connection, twin-head, cast iron, 1 × 230–240 V, standard module; product number 96408910; net weight 56.0 kg. |
Key specifications
| Flanged connection (nominal diameter) | 32–100 mm |
|---|---|
| Pressure rating | PN 6/PN 10 in a single version (32–65 mm); for 80 and 100 mm, separate versions: PN 6 or PN 10 |
| Liquid temperature | −10…+120 continuous; +140 for short periods; up to +60 for domestic hot water °C |
| Ambient temperature | 0…40 °C |
| Speed steps | 3 (single-phase: approx. 60 / 80 / 100 %; three-phase: approx. 70 / 85 / 100 % of maximum speed) |
| Power supply | 1 × 230–240 V or 3 × 400–415 V, 50 Hz |
| Pump body | EN-GJL-250 cast iron or CuSn10Pb bronze |
| Wet rotor, bearings | Ceramic radial bearings and carbon thrust bearing; rotor can, rotor cladding and bearing plate in stainless steel |
| Protection class | IPX4D |
| Water/glycol mixture | up to 50 % |
The data come from the Grundfos datasheet "Series 200 – UPS, UPSD circulator pumps, 50/60 Hz" (74 pages, created in October 2015), published on the official Grundfos literature server; the current status of each type and the valid order code are confirmed in the quotation.
Frequently asked questions
How do I read a code like UPS 40-180 F 250?
UPS = single-head circulator (UPSD = twin-head); 40 = nominal flange diameter in mm; 180 = maximum head in dm (18 m); F = pump with flanges (B = bronze body); 250 = port-to-port length in mm. If the pump exists with both a 2-pole and a 4-pole motor, the number of poles appears after the head, for example /2.
What liquids can be pumped and up to what temperature?
Clean, thin, non-aggressive and non-explosive liquids, without solid particles, fibres or mineral oil, between −10 and +120 °C continuous, with short-term peaks up to +140 °C; domestic hot water up to +60 °C. Water/glycol mixtures are permitted up to 50 %, with reduced performance. For domestic hot water, the datasheet recommends bronze pumps for water with a hardness below approximately 14 °dH.
What does the relay module do on the UPSD variant?
The datasheet lists UPSD pumps with both the relay module and the standard module; the relay module allows alternating operation (change-over every 24 hours, each pump running in turn and on standby), standby operation or operation with independent pumps. Pumps with the protection module or relay module must not be connected to a frequency inverter.
Other Grundfos series
The UPS/UPSD range includes many combinations of size, voltage, material and terminal box module; we confirm the exact code and the available variant from the complete code on the nameplate.