Halton supplier in Romania
For Halton we quote control dampers CCD-01, isolation dampers CID-02, fire dampers FCE, smoke control dampers SFC and pressure relief dampers CPR-01, louvres CWL-01 and moisture eliminators SL/HL; we need the code, the dimensions and the operating environment.
Who is Halton and what does it make?
Halton offers indoor air solutions for spaces with strict requirements, grouped in six families: air conditioning for rooms and cabins, ventilation for kitchens and on-board pantries, airflow management and outdoor air intakes, air treatment, fire and smoke safety, and ventilation for cleanrooms and laboratories. For industrial installations the range includes dampers, louvres and moisture eliminators.
The control damper CCD-01 has a steel casing and aerodynamic-profile blades, can be manual or automatic and is fitted in any position. A single unit reaches 1275×1800 mm, and multiple assemblies reach 3925×3650 mm. Leakage across the blades is class 3, and through the casing class C, under EN 1751:2014. It is rated SIL 2 (safety integrity level) under IEC 61508-2:2010 and ATEX certified under Directive 2014/34/EU. The isolation damper CID-02, with a single blade, has dimensions of at most 600×300 mm and withstands a pressure test of 5,000 Pa for 60 minutes.
The fire damper FCE (EI 60 S) closes automatically at 72 °C or more, has an EN 13501-3 classification, is CE marked under EN 15650 and covers rectangular ducts of 150–1000 mm or circular ducts Ø100–1000 mm. The smoke control damper SFC has diameters between 100 and 630 mm and the classification E600 120 S. For a quotation, the code, the dimensions, the actuation type and the ATEX zone matter.
What do we supply from the Halton range?
| Product | Description |
|---|---|
| Control and isolation dampers (CCD, CID, CBD, CRD, CPR) | Control dampers CCD-01 and CCD-02, isolation dampers CID-02, non-return dampers CBD-01 and CBD-02, gas-retention dampers CRD-01 and pressure relief dampers CPR-01, for industrial ventilation installations, with galvanised steel or stainless steel versions. |
| FCE fire dampers | The fire damper FCE (EI 60 S) for rectangular ducts of 150–1000 mm and circular ducts Ø100–1000 mm, with a spring-return electric actuator (FCE-EL, 24–230 V) and ATEX versions. |
| SFC smoke control dampers | The uninsulated SFC damper, in galvanised steel, with diameters Ø100–630 mm, for smoke extraction ducts, with a 15 Nm electric actuator at 24 V or 230 V and classification E600 120 S. |
| Louvres and moisture eliminators | Weather louvres CWL-01 and CWL-01C, moisture eliminators SL and HL, and the under-platform extraction grille UPE, for outdoor intakes and exhausts of ventilation. |
Why Halton?
- CCD-01 and CID-02 dampers with SIL 2 and ATEX — suited to isolating and controlling air in hazardous industrial environments
- Large dimensions: CCD-01 up to 1275×1800 mm in one unit — covers wide ducts without assembling several modules
- FCE fire damper with automatic closing at 72 °C and classification EI 60 S or E 120 S — protection of fire compartmentation
- SFC with classification E600 120 S — smoke control damper for extraction ducts
- Dampers with electric, pneumatic or manual actuation — the choice is made by the existing control system
Which Halton codes and series are requested most often?
| Code | Description |
|---|---|
| CCD-01 | Control damper, SIL 2 and ATEX, up to 1275×1800 mm |
| CCD-02 | Control damper |
| CID-02 | Isolation damper with one blade, zero leakage, 5,000 Pa |
| CBD-01 | Non-return damper |
| CBD-02 | Non-return damper |
| CRD-01 | Gas-retention damper |
| CPR-01 | Pressure relief damper |
| FCE | Fire damper EI 60 S, automatic closing at 72 °C |
| FCE-EL | FCE version with spring-return electric actuator |
| SFC | Smoke control damper, Ø100–630 mm, E600 120 S |
| CWL-01 | Weather louvre with fixed blades |
| HL / SL | Moisture eliminators |
Where is Halton equipment used?
- Industrial installations with a hazardous environment — ATEX and SIL 2 dampers for isolation
- Ventilation for kitchens and on-board pantries — a dedicated product family
- Cleanrooms and laboratories — ventilation with strict air requirements
- Air treatment — exhaust fans, make-up air units and pollution control units
- Fire and smoke safety — fire dampers and smoke control dampers in ducts
How do we supply Halton in Romania?
We can quote Halton dampers and components for industrial ventilation installations. For a correct quotation, send the product code (for example CCD-01, CID-02, FCE or SFC), the duct dimensions, the actuation type (electric, pneumatic or manual), the material (galvanised steel or stainless steel) and, where relevant, the ATEX zone and the SIL requirement. A photo of the nameplate of the existing damper shortens the identification. Dampers are supplied to order for each project: usually 1–4 weeks, and a standard part can ship in 24–72 h when the item is in stock, locally or at the supplier. You receive the exact lead time in the quotation.
Certifications and fire classifications are checked in the quotation, for each dimension and mounting version requested.
Frequently asked questions about Halton
What are CCD-01, CID-02, FCE and SFC at Halton?
CCD-01 is the control damper, up to 1275×1800 mm, CID-02 is the single-blade isolation damper with zero leakage, FCE is the fire damper EI 60 S, with automatic closing at 72 °C, and SFC is the smoke control damper, Ø100–630 mm.
How do I choose between the CCD-01 and CID-02 damper?
CCD-01 controls the flow, with leakage across the blades of class 3, in units of up to 1275×1800 mm. CID-02 is a single-blade isolation damper, up to 600×300 mm, with a 5,000 Pa test. Send the duct dimensions and the purpose, and we identify the suitable version.
Are Halton dampers supplied in Romania, and how quickly?
Dampers are supplied to order, usually in 1–4 weeks; the lead time is 24–72 h when the item is in stock, locally or at the supplier. For special dimensions the lead time may be longer. We confirm the exact date in the quotation.
What actuation can I choose for an FCE fire damper?
FCE closes automatically at 72 °C or more and can also be triggered by a local switch or by the automation system. The electric actuator FCE-EL works between 24 and 230 V; Ex actuators also exist. Send the voltage and the ATEX zone.
What data must I send for a quotation on a Halton damper?
Send the code (CCD-01, CID-02, FCE, SFC or another), the duct dimensions, the shape (rectangular or circular), the material, the actuation type, the voltage and, where relevant, the ATEX zone or the SIL level. A photo of the nameplate of an existing damper helps with identification.
How do I request a Halton quotation?
Send the Halton code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Halton (manufacturer documentation)