Hillger NDT supplier in Romania
For Hillger NDT we quote the USPC 30XX immersion systems, the USPC 3011 NF and USBUS low-frequency systems, the USPC 4000 AirTech system and the FlatScan, RobockScan and ConeScan scanning installations, depending on the material and thickness of the parts.
Headquarters: Braunschweig, Germany
Who is Hillger NDT and what does it make?
Hillger NDT is a German company from the Braunschweig area, specialising in the development of ultrasonic systems for the non-destructive testing of materials. The equipment produces images of internal defects, in the form of A, B, C, D and F scans, on materials such as metals, carbon-fibre or glass-fibre reinforced composites (CFRP, GFRP), foams, wood and concrete. The programme is divided into immersion systems, air-coupled ultrasonic systems, low-frequency systems, complete scanning installations and structural health monitoring.
The USPC 30XX series comprises immersion imaging systems, with bandwidths of 10, 20, 35, 65 and 200 MHz, built from an industrial computer, a motor controller, an acquisition board and a HILL-SCAN transmitter-receiver. The USPC 3060 UHF goes up to 200 MHz, with pulses under 100 ns, so it inspects thin components, such as steel from 0.1 mm thick. The USPC 3011 NF works up to 10 MHz for materials that are hard to investigate, and the USBUS is the USB version for research and education. The USPC 4000 AirTech uses air-coupled probes, without water. The FlatScan installations (1000 × 1000 and 2500 × 2500 mm, flat parts up to 90 mm), the RobockScan for rotating parts, the ConeScan for conical parts and the 10-axis robot cells complete the offer. All are controlled by the Hillgus software.
Such systems are of interest to materials laboratories, manufacturers of composite components and of brazed or welded joints, non-destructive testing companies and research institutes. The choice depends on the material and thickness of the part, the frequency required, the shape of the part and the coupling method, which is why the quotation starts from the type of part and the defects sought.
What do we supply from the Hillger NDT range?
| Product | Description |
|---|---|
| USPC 30XX and HILL-SCAN | Immersion ultrasonic systems, with bandwidth from 10 to 200 MHz, for A, B, C, D and F images; the HILL-SCAN 3011 NF, 3010, 3010 HF, 3010 VHF and 3060 UHF cards use VMOS or avalanche transmitters. |
| USPC 3011 NF and USBUS | Low-frequency systems, up to 10 MHz, for materials that are hard to investigate, such as wood, concrete, foams and thick composites; the USBUS 3011 NF brings the same technique into a USB device, for research and education. |
| USPC 4000 AirTech | Air-coupled ultrasonic testing system, without water as the coupling medium, with a transmitter of 3 ohm internal resistance, a very low-noise amplifier and AirTech probes, in a stationary 19-inch version or a mobile one. |
| FlatScan, RobockScan and ConeScan | Scanning installations: FlatScan for flat parts up to 90 mm, in transmission or pitch-catch, RobockScan for rotating composite parts up to 7 m, ConeScan for conical parts, with spiral scanning. |
Why Hillger NDT?
- Bandwidth up to 200 MHz — USPC 3060 UHF with pulses under 100 ns for very thin components, including steel from 0.1 mm
- Five bandwidth classes in the same series — USPC 30XX from 10 to 200 MHz, with acquisition boards from 100 MS/s to 1 GS/s
- Testing without water — USPC 4000 AirTech uses air-coupled probes, with a transmitter of up to 1.2 kW pulse power
- Installations completed with scanning mechanics — FlatScan for flat parts, RobockScan and ConeScan for rotating or conical parts
- One software for all systems — Hillgus controls the scan, displays the A-scan in real time and exports data in open formats
Which Hillger NDT codes and series are requested most often?
| Code | Description |
|---|---|
| USPC 3060 UHF | Ultrasonic imaging system, bandwidth up to 200 MHz |
| USPC 3010 | Immersion imaging system, 20 MHz bandwidth |
| USPC 3010 HF | Immersion imaging system, high bandwidth |
| USPC 3010 VHF | Immersion imaging system, very high bandwidth |
| USPC 3011 NF | Low-frequency system, up to 10 MHz |
| USBUS 3011 NF | USB device with low-frequency technique |
| USPC 4000 AirTech | Air-coupled ultrasonic system |
| HILL-SCAN 3060 UHF | Transmitter-receiver card with adjustable pulse |
| HILL-SCAN 3010 | Transmitter-receiver card with VMOS pulser |
| FlatScan 1000 | Scanner for flat parts, 1000 × 1000 mm area |
| FlatScan 2500 | Scanner for flat parts, 2500 × 2500 mm area |
| RobockScan | Installation for rotating composite parts |
| ConeScan | Installation for conical parts |
| Hillgus | Control and acquisition software for systems |
Where is Hillger NDT equipment used?
- Composites and aeronautics — scanning of CFRP and GFRP parts, including free-form parts
- Metals and joints — defects in metal parts, brazed and adhesive joints
- Construction materials — concrete, wood and foams, with low-frequency ultrasound
- Electronics and semiconductors — very thin components and contacts
- Research and education — USB systems for the laboratory
How do we supply Hillger NDT in Romania?
We can quote Hillger NDT ultrasonic testing systems, from immersion and low-frequency modules to scanning installations with mechanics and software, supplied to order. The lead time is usually 1–4 weeks to order and, depending on the specification, may be longer, because the installations are configured for the application. For a quotation, send us the material and thickness of the parts, the dimensions, the type of defects sought, the frequency or bandwidth wanted, the coupling method (immersion or air) and whether you need automatic scanning or a single axis.
The frequency and the scanning mechanics are to be set once we know the material, thickness and shape of the parts to be tested.
Frequently asked questions about Hillger NDT
What does Hillger NDT make?
Hillger NDT, from the Braunschweig area, develops ultrasonic systems for materials testing: immersion, air-coupled ultrasound, low frequency, scanning installations, the Hillgus software and structural health monitoring systems. The result is an image of internal defects, without destroying the part.
How do I choose the frequency band for my parts?
Low frequency, up to 10 MHz, suits concrete, wood, foams and thick composites; the 35 to 200 MHz bands see thin parts, brazed joints or contacts, and 200 MHz reaches 0.1 mm steel. Send us the material and the thickness to narrow down the options.
Do you supply Hillger NDT systems in Romania, and how quickly?
Yes, to order, usually in 1–4 weeks; depending on the specification, the lead time may be longer, especially for scanning installations with mechanics. The exact lead time is confirmed in the quotation.
How do you check whether a new system can replace an older Hillger one?
We compare the model and series of the system, the frequency band, the acquisition board, the scanning mechanics and the software version. Equivalence is assessed once these data are available; a photo of the nameplate and a list of the parts tested help with the check.
What do I send for a quotation on a FlatScan or RobockScan installation?
Send the maximum dimensions of the part, the thickness, the material, the type of coupling wanted (air or water), the scanning resolution and whether the part is flat, rotating or conical. FlatScan works with flat parts up to 90 mm, and RobockScan with parts up to 7 m.
How do I request a Hillger NDT quotation?
Send the Hillger NDT code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Hillger NDT GmbH (manufacturer documentation)