For Jean Müller we quote NH gG and aM fuses, HRC fuses for industry, NH fuse bases and SL series fuse switch disconnectors (SL00–SL3); the code on the body or label is enough for us to quote.

Founded in 1897 · Headquarters: Eltville am Rhein, Germany

Request a quote

Who is Jean Müller and what does it make?

Jean Müller is a German manufacturer of high-performance fuse-links for protecting industrial electrical installations. For over 125 years it has made NH (blade-type) and HRC (High Rupturing Capacity) fuses that protect transformers, motors, capacitors, inverters and electric cables against short circuits and overloads. The company is based in Eltville am Rhein and does business in 64 countries.

The manufacturer's technology is based on filling the ceramic body with calibrated quartz sand that absorbs the energy of the electric arc on breaking. When the short-circuit current reaches 10-100 kA, the fuse element melts within microseconds, and the sand extinguishes the arc before it can destroy downstream equipment.

The characteristics of each fuse type (I²t, time-current characteristic) are those in the manufacturer's documentation for the code concerned; compatibility when completing an existing set is checked by code.

What do we supply from the Jean Müller range?

ProductDescription
NH gG 400V FusesThe NH (Niederspannungs-Hochleistungs) range covers several rated currents; the ratings and voltages available are confirmed from the manufacturer's documentation. Blade form according to IEC 60269-2, sizes 00/000/0/1/2/3/4 compatible with all standard European bases. The gG (general purpose) characteristic provides full protection for cables and apparatus - at low currents (1.6×In) melting takes hours, at short circuit melting is fast; the exact values result from the time-current characteristic in the datasheet. Ceramic body filled with quartz sand; construction details are confirmed from the datasheet. A red mechanical indicator appears when the fuse has blown.
NH aM Fuses for MotorsThe aM (accompanying motor fuse) version is optimised for protecting electric motors on direct starting. It lets the starting current pass (6-8×In for 5-10 seconds) without blowing, but breaks immediately on short circuit. Fuse elements with variable cross-section and constriction points calculated for the desired characteristic are used. Ratings and power dissipation are confirmed from the datasheet. They are fitted in series with the motor contactor for back-up protection - the contactor breaks the overload, the NH fuse breaks the short circuit.
HRC 690V Fuses for IndustryThe HRC (High Rupturing Capacity) line for 690V AC is used in high-voltage industrial installations - 20kV/690V transformers, 500kW+ motors, high-power frequency inverters. Breaking capacity, operating classes, ratings and certifications (for example UL/CSA) are confirmed from the manufacturer's documentation for each code. Versions with a mechanical striker for operating an auxiliary switch on melting.
NH Fuse Bases with DisconnectorModular NH bases allow mounting on 35mm DIN rail or on a plate, with a transparent phase barrier for IP20 protection. Contact details are confirmed from the datasheet. Versions for 1-3 poles, with or without isolation (the rotary-handle model allows disconnection under load up to In). Upper and lower terminals for 1.5-240 mm² cable or copper busbar.

Why Jean Müller?

  • High breaking capacity - the exact value for each type is confirmed from the datasheet
  • I²t characteristic - values for each rating are taken from the manufacturer's documentation; selectivity is set by the designer
  • Ceramic body filled with quartz sand for extinguishing the electric arc
  • Integrated mechanical blow indicator - you see instantly which fuse has blown, without a multimeter
  • Silver-plated contacts - contact resistance and power losses are confirmed from the datasheet
  • Quality control - test procedures are confirmed from the manufacturer's documentation

Which Jean Müller codes and series are requested most often?

CodeDescription
SL00NH fuse switch disconnector size 00, current up to 160A
SL1NH fuse switch disconnector size 1, current up to 250A
SL2NH fuse switch disconnector size 2, current up to 400A
SL3NH fuse switch disconnector size 3, current up to 630A
SL3-910ANH incomer disconnector for secondary protection of 630 kVA transformers
SL3-910Aplusincomer fuse switch disconnector with thermal current up to 1000A
SL3-1000Aincomer disconnector code; exact description confirmed from the manufacturer's documentation
TOKEOsmart NH fuse switch disconnector with integrated monitoring electronics
KETONH fuse switch disconnector; characteristics confirmed from the manufacturer's documentation
SASILpluscompact fuse switch disconnector for secure power supply
D/D0range of compact fuses for non-professional use and terminals
HH (IKUS series)fuses for high-voltage applications, IKUS range
NH00-NH3 bazeNH fuse bases for plate or busbar mounting
PVfuse dedicated to protecting DC photovoltaic systems
aR semiconductorultra-fast fuse for protecting power semiconductors

Where is Jean Müller equipment used?

  • Power distribution - low-voltage electrical switchboards
  • Motors & Drives - motor protection, frequency inverters
  • Renewable Energy - photovoltaic panels, wind turbines, batteries
  • Marine & Offshore - ship installations, oil platforms
  • Mining - mine transformers, excavator motors
  • Railways - train power supply, traction substations
  • Steel & Metallurgy - electric arc furnaces, rolling mills
  • Chemical - pumps, compressors, agitators in ATEX zones
  • Data Centers - UPS, transformers, distribution panels
  • Water Treatment - high-power pumps, air blowers

How do we supply Jean Müller in Romania?

We source Jean Müller fuses to order, and availability is confirmed case by case with the supplier. We take the information on ratings and characteristics from the manufacturer's technical documentation. As a general rule, common NH and HRC fuses can arrive in 24–72 h when the item is in stock, locally or at the supplier, while large batches or rare ratings go through the ordering flow, usually in 1–4 weeks. For an accurate quotation we need the rated current, the installation voltage and the number of pieces. Selectivity of the electrical installation remains the designer's responsibility.

The availability of each Jean Müller fuse rating is checked on request; selectivity of the electrical installation is calculated by the designer.

Frequently asked questions about Jean Müller

How do I choose the right size of a Jean Müller NH fuse, for example between SL1 and SL2?

The size depends on the rated current of the line and on the physical space in the existing switchboard. SL1 covers up to 250A and SL2 up to 400A, but correct sizing also takes into account the short-circuit current of the network. We recommend checking the full code marked on the existing disconnector before ordering a replacement, to avoid a sizing error in the installation.

Do you supply Jean Müller fuse switch disconnectors in Romania?

Yes, we bring in disconnectors from the SL, TOKEO or SASILplus ranges to order, based on the code confirmed by the customer. This range is supplied to order and we refer to the manufacturer's technical documentation; the lead time to order is usually 1–4 weeks. It helps to send the full code from the label of the existing disconnector, to identify exactly the version compatible with the installation.

What do I need to specify for an NH fuse quotation?

You need the NH size (00 to 3), the operating class (gG for general use or aM for motor protection), the rated current and the working voltage. For mounting bases also state the connection type, plate or busbar. A photo of the existing part helps avoid confusion between close variants of the same range.

What is the difference between the SL series and the TOKEO disconnector from Jean Müller?

SL is the classic series of fuse switch disconnectors, available in sizes 00 to 3 and in versions for high incomer currents. TOKEO adds electronics for monitoring the state of the installation and signalling possible problems, and is designed for applications where additional supervision is wanted. The choice depends on the complexity of the switchboard and the need for active monitoring.

How do I find the equivalent of an older Jean Müller NH fuse base?

We compare the NH size, the distance between terminals and the connection type (plate or busbar) with the current ranges in the manufacturer's technical documentation. A clear photo of the existing base, together with the NH size written on the body, is usually enough for identification. Final confirmation is made after checking the rated current needed in the installation.

How do I request a Jean Müller quotation?

Send the Jean Müller code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote