Lantronix supplier in Romania
For Lantronix we quote UDS1100, UDS2100, xDirect and EDS serial servers, SLC 8000 and SLC 9000 console servers, media converters, SISPM switches and G520 and NTC gateways, on the basis of the serial interfaces, the protocol and the mounting method required.
Headquarters: Irvine (California), USA
Who is Lantronix and what does it make?
Lantronix, based in Irvine, California, makes network equipment that connects devices not designed for it to Ethernet and to cellular networks: serial device servers, console servers for out-of-band management, media converters, industrial switches with power over Ethernet (PoE) and industrial gateways or routers for LTE and 5G connections. For an automation or maintenance engineer, these are the parts that bring onto the network an analyser, a meter, an old controller with an RS-232, RS-422 or RS-485 port or equipment located in a place without a network cable.
The range is divided into families. The serial servers include the UDS1100 and UDS2100 families, xDirect and xDirect-IAP, with one serial port and Modbus, XPress DR+ for DIN rail mounting, EDS1100, EDS2100, EDS3000PS (8–16 serial ports), EDS4100 and EDS5000, plus the rugged SDSTX3110 models with 1 or 4 RS-232/422/485 ports. The console servers are SLC 8000, modular, expandable up to 48 ports, and SLC 9000, while EMG 7500 and EMG 8500 are intended for remote offices. The media converters range from Fast Ethernet to 10G and T1/E1.
For gateways there are the G520, X300, E210 and M110 series and the NTC-201, NTC-220, NTC-500 and NTC-550 routers, with LTE or 5G. In industrial installations, such equipment appears in the monitoring of pumping stations and transformer stations, of process lines and of remote access systems, where the serial port, the protocol, the supply voltage and the working temperature matter. The quotation starts from the model or from the interfaces required.
What do we supply from the Lantronix range?
| Product | Description |
|---|---|
| Serial device servers (UDS, xDirect, EDS, SDSTX) | UDS1100 and UDS2100 are external servers, xDirect-IAP has one serial port and Modbus support, XPress DR+ is mounted on a DIN rail, and SDSTX3110 includes rugged models with 1 or 4 RS-232/422/485 ports and two 10/100Base-TX Ethernet ports. EDS3000PS offers 8–16 serial ports. |
| SLC 8000 and SLC 9000 console servers | SLC 8000 is a modular console manager, with RS-232 and USB ports, expandable up to 48 ports. SLC 9000 is the new generation, with autonomous out-of-band management, while EMG 7500 and EMG 8500 are management gateways for remote offices, with up to 8 console ports. |
| Media converters and rugged switches | Fast Ethernet, Gigabit and 10G media converters (C2110, C3110, C4110 series), E-100BTX-HT rugged converters, PoE injectors and SISPM and SISGM switches with PoE+ or PoE++, in managed and unmanaged versions, including Layer 3. |
| Industrial gateways and routers | The G520, X300, E210 and M110 series and the NTC-201, NTC-220, NTC-500 and NTC-550 routers, with LTE or 5G connection, for connecting equipment in isolated places to the network. E210 has two Ethernet ports and support for two SIM cards. |
Why Lantronix?
- Serial servers for older equipment — UDS1100, UDS2100, xDirect and EDS bring an RS-232, RS-422 or RS-485 port onto the network without changing the device
- DIN rail mounting and rugged models — XPress DR+ and the SDSTX3110 series, with 1 or 4 serial ports, for automation cabinets
- Modular console servers — SLC 8000 expands up to 48 RS-232 or USB console ports for out-of-band management of network equipment
- LTE and 5G cellular gateways — G520, X300, E210, M110 and NTC for sites without access to a fixed network
- Switches and media converters in the same range — from Fast Ethernet to 10G, with PoE+ and PoE++ versions for cameras and access points
Which Lantronix codes and series are requested most often?
| Code | Description |
|---|---|
| UDS1100 | External server for serial devices |
| UDS2100 | External server for serial devices, 2 ports |
| xDirect-IAP | Serial server with one port and Modbus support |
| XPress DR+ | Industrial serial server for DIN rail |
| EDS3000PS | Multiport server, 8–16 serial ports |
| EDS5000 | Serial server for remote connection and management |
| SDSTX3110-124-LRT-B | Rugged serial server, 4 RS-232/422/485 ports |
| SLC 8000 | Modular console manager, up to 48 ports |
| SLC 9000 | Console manager with out-of-band management |
| EMG 8500 | Management gateway with modular chassis, up to 8 ports |
| E-100BTX-HT | Rugged Fast Ethernet media converter |
| C3110 | Gigabit media converter for fibre |
| SISPM1040-384-LRT-C | Rugged managed switch, 8 PoE+ ports and 4 SFP |
| G520 | Rugged LTE and 5G cellular gateway |
| E210 | Cellular router with two SIM cards and two Ethernet ports |
| NTC-220 | Industrial LTE 4G router |
Where is Lantronix equipment used?
- Industrial automation — connecting controllers and devices with a serial port to Ethernet
- Utilities and water — monitoring pumping stations and remote stations over LTE or 5G
- Energy — remote access to equipment in transformer stations and power plants
- Data centres and telecommunications — console servers for out-of-band management
- Transport and infrastructure — rugged PoE switches for cameras and access points
How do we supply Lantronix in Romania?
We can quote Lantronix serial servers, console servers, media converters, switches and gateways, bringing them in to order. The lead time is usually 1–4 weeks to order, and depending on the specification it can be longer for the rugged versions and for the 5G cellular ones. For an accurate quotation, send us the type of serial interface (RS-232, RS-422 or RS-485), the number of ports, the protocol used, the mounting method (DIN rail or rack), the supply voltage, the working temperature range and, for gateways, the cellular band required. For existing equipment, add the model from the label.
Compatibility with an older device is determined from the serial interface, the protocol and the supply voltage, not only from its name.
Frequently asked questions about Lantronix
What does Lantronix make?
Lantronix makes network connectivity equipment: serial device servers, console servers, media converters, switches with PoE and LTE and 5G cellular gateways or routers. It is based in Irvine, California. The range helps bring older equipment with a serial port, and equipment in isolated places, onto the network.
How do I choose a serial server for a device with RS-485?
What matters is the number of ports, the interface (RS-232, RS-422 or RS-485), the protocol, for example Modbus, and the mounting method. For a DIN rail, XPress DR+; for a single device, xDirect-IAP; for several, EDS or UDS2100. Send us the device data and we recommend the family.
How long does it take to receive Lantronix equipment in Romania?
Supply is to order. The usual lead time is to order, usually 1–4 weeks; rugged models or those with a 5G modem can take longer, depending on the specification. We give you the precise lead time with the quotation, once we have determined the code.
Can I replace a UDS1100 with a current model?
It is checked on the basis of the serial interface used, the speed, the protocol, the power method (including PoE) and the existing configuration. A direct replacement is confirmed after the comparison; send the label from the device and a description of the serial link.
What do I send for a quotation for a cellular gateway?
State the band required (LTE or 5G), the number of Ethernet and serial ports, whether you need two SIM cards, the supply voltage, the working temperature and the mounting method. If you are replacing equipment, add the model from the label so that we can check compatibility.
How do I request a Lantronix quotation?
Send the Lantronix code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Lantronix (manufacturer documentation)

