Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Meinberg supplier in Romania

For Meinberg we quote LANTIME servers from the M150 to M4000 series, PTP grandmasters, IMS-HPS100 and IMS-PSX210 modules, microSync and PCIe clocks; we need the device series, the outputs required and the reference source.

Founded in 1979 · Headquarters: Bad Pyrmont, Germany

Request a quote

Who is Meinberg and what does it make?

Meinberg is a German company, founded in 1979 and based in Bad Pyrmont, specialising in time and frequency synchronisation. The products are developed and manufactured in the same place, from concept to series production. The range includes NTP time servers, IEEE 1588 (PTP) grandmaster clocks, GNSS receivers, PCI and PCIe computer clocks, IRIG time code generators and readers, signal distribution, antennas and time displays. In energy and telecommunications, the main interest is providing a common time reference for intelligent electronic devices (IED), SCADA systems and data networks.

The products include the LANTIME servers, available in series such as M150, M250, M320, M450, M500, M1000, M2000S, M3000 and M4000. The M450 series is a time source for substation automation. The modular IMS (Intelligent Modular System) platform takes modules such as IMS-HPS100 and IMS-PSX210, and microSync is the compact family of synchronisation clocks. The LANTIME PTP Grandmaster versions have an OCXO HQ oscillator and support several PTP profiles, including those for energy (IEEE C37.238) and, for telecommunications networks, ITU-T G.8265.1 and G.8275.1.

The target applications are energy, broadcasting, the financial sector and transport, where time accuracy is measured in nanoseconds. For existing systems there are GNSS receivers for computers, DCF77 clocks and IRIG code systems, and the match with an older unit is established by series, modules and the outputs used.

What do we supply from the Meinberg range?

ProductDescription
LANTIME NTP time serversSeries M150, M250, M320, M450, M500, M1000, M1000S, M2000S, M3000, M3000S and M4000, with GNSS synchronisation, rack or rail mounting. They can have additional Ethernet ports, including fibre. M450 is recommended for substation automation.
LANTIME PTP GrandmasterIEEE 1588v2 grandmaster clocks with an OCXO HQ oscillator, multi-profile (including IEEE 1588-2008 and IEEE C37.238), suited to IED, SCADA and telecommunications networks with ITU-T G.8265.1 and G.8275.1 profiles.
IMS and microSyncIMS is the modular synchronisation platform, with modules such as IMS-HPS100 and IMS-PSX210. microSync is the compact family of PTP and NTP devices for installations where a full system would be disproportionate.
PCI/PCIe, GNSS, DCF77 and IRIG clocksGNSS receivers as PCI and PCIe cards, DCF77 clocks and modules for IRIG time code, as well as readers and generators. Used to bring exact time directly into a computer or a measuring instrument.

Why Meinberg?

  • LANTIME NTP servers in series from M150 to M4000 — from a small network to redundant systems for large infrastructures
  • PTP grandmasters with an OCXO HQ oscillator and multiple profiles — suited to energy substations and telecommunications networks
  • Modular IMS platform — synchronisation modules added over time, without replacing the whole system
  • GNSS receivers, DCF77 and IRIG time code — varied reference sources for different environments
  • Manufacturing and development in Bad Pyrmont — control over the product from design to series production

Which Meinberg codes and series are requested most often?

CodeDescription
LANTIME M150NTP time server
LANTIME M250NTP time server
LANTIME M320NTP time server
LANTIME M450Time server for substation automation
LANTIME M500NTP time server
LANTIME M1000NTP time server
LANTIME M2000SNTP time server
LANTIME M3000NTP time server with optional modules
LANTIME M4000NTP time server
LANTIME PTP GrandmasterIEEE 1588 grandmaster clock with NTP
IMS-HPS100IMS synchronisation module
IMS-PSX210IMS PTP/synchronisation module
microSyncCompact family of synchronisation clocks
PTP270PEXPTP slave clock, PCI Express

Where is Meinberg equipment used?

  • Energy — synchronisation for IED, SCADA and substations
  • Telecommunications — network synchronisation through time and frequency references
  • Broadcasting — synchronisation of studio equipment over IP
  • Financial sector — time reference for data systems
  • Transport — time reference for control systems

How do we supply Meinberg in Romania?

We can quote LANTIME time servers, PTP grandmaster clocks, IMS modules, microSync, PCI/PCIe clocks and GNSS antennas, mainly for modernising or completing existing synchronisation systems. Delivery is to order, usually in 1–4 weeks; configured modular systems may take longer. For a correct quotation, send us the device series from the label (for example M450 or M1000), the type of outputs needed (NTP, PTP, IRIG, pulses), the reference source (GNSS, DCF77) and the number of synchronised clients. For replacements, add the list of installed modules.

Availability of an IMS modular configuration is established from the exact list of modules and options required.

Frequently asked questions about Meinberg

What does Meinberg make?

Meinberg makes time and frequency synchronisation systems: LANTIME NTP servers, IEEE 1588 PTP grandmasters, GNSS receivers, PCI and PCIe clocks, IRIG modules, antennas and time displays. The company is German, founded in 1979, and the products are manufactured in Bad Pyrmont.

How do I choose between an NTP server and a PTP grandmaster?

NTP is used to synchronise computers and servers in a network, while IEEE 1588 PTP is used when devices (IED, measurement systems, telecommunications networks) need much finer accuracy, in the nanosecond range. Tell us which equipment you are synchronising and which PTP profile it requires, and we will propose the series.

Do you supply Meinberg equipment in Romania, and within what lead time?

Meinberg equipment is supplied to order, usually in 1–4 weeks. A unit can ship in 24–72 h when the item is in stock, locally or at the supplier. For modular IMS systems with several modules the lead time may be longer, and we give it in the quotation.

Can I replace an old Meinberg clock or server?

It can be checked, and equivalence is confirmed after comparison. Send us the series from the label, the installed modules or cards, the outputs used (NTP, PTP, IRIG, pulses) and the reference source. Based on these, we tell you which current model can take over the functions.

What data should I send for a synchronisation system quotation?

State the number of synchronised clients, the protocols needed (NTP, PTP and the profile, IRIG), the time source (GNSS, DCF77), the mounting type (rack or rail) and whether you want redundancy. For a substation project, also mention the automation protocol used.

How do I request a Meinberg quotation?

Send the Meinberg code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Meinberg Funkuhren (manufacturer documentation)