Who is LTB Lasertechnik Berlin and what does it make?

LTB Lasertechnik Berlin GmbH develops and manufactures short-pulse UV lasers, high-resolution spectrometers, laser-based measurement technology and systems for laser material processing. It is based in Berlin and has worked in laser measurement for over 35 years. Its core competences include nitrogen lasers and the ARYELLE echelle spectrometers, which it also uses in its own LIBS and Raman analysers.

The products fall into three areas. Lasers: MNL 100, a compact nitrogen laser, under 3 litres and about 3.5 kg, with no external gas supply, with 60 million pulses or two years of operation without maintenance; qMNL-1000, a DPSS laser at 336 nm, with a 4 ns pulse and a frequency of up to 1 kHz, with the series spanning 355 to 1342 nm. Spectrometers: ARYELLE 200, with a focal length of 200 mm and an f/10 ratio, usable with CMOS, CCD, EMCCD or ICCD detectors, for LIBS and Raman; ARYELLE 400; and ARYELLE Butterfly, which brings together two 400 mm spectrographs, one for VUV and one for UV-VIS-NIR, on a single detector. Analysers: CALIBSO, a laboratory LIBS system with a 6-megapixel camera and selection of measuring points on the image, and CORALIS, which combines Raman and LIBS, useful for technical cleanliness, particles and forensics.

It is of interest to metallurgy, geology, environmental and research laboratories that need direct elemental analysis, on aluminium and steel or on geological samples, or components for building their own set-up. The choice starts from the spectral range and the sample type.

What do we supply from the LTB Lasertechnik Berlin range?

ProductDescription
ARYELLE 200 and ARYELLE 400UV-VIS-NIR echelle spectrographs, fibre-coupled, for LIBS and Raman spectroscopy. ARYELLE 200 has a 200 mm focal length and f/10, while ARYELLE 400 offers higher resolution; both accept several detector types.
ARYELLE ButterflyDual echelle spectrograph with two separate spectral ranges (VUV and UV-VIS-NIR), each with a 400 mm focal length and a common detector, in a compact, thermally stable housing, for precise elemental analysis.
CALIBSOLaboratory LIBS system for qualitative and quantitative elemental analysis. The measuring points are chosen on an image of the sample, and the Sophi nXt software controls all components. The robust housing has an integrated safety circuit for user protection.
CORALIS and MNL lasersCORALIS is the combined Raman-LIBS system for particles and technical cleanliness. MNL 100 is a compact nitrogen laser, and qMNL-1000 a 336 nm DPSS laser with active triggering.

Why LTB Lasertechnik Berlin?

  • ARYELLE 200, 400 and Butterfly echelle spectrometers — high spectral resolution in a compact format, for LIBS and Raman
  • MNL 100 runs without an external gas supply and has 60 million pulses between interventions — suitable for installations with infrequent maintenance
  • CALIBSO selects the measuring points on a quality image, with a 6 MP camera — contactless elemental analysis
  • CORALIS combines Raman and LIBS on the same point — molecular and elemental information in a single instrument
  • Applications on aluminium and steel, geology, forensics and research — from components to complete analysers

Which LTB Lasertechnik Berlin codes and series are requested most often?

CodeDescription
ARYELLE 200Compact echelle spectrograph, 200 mm focal length
ARYELLE 400Echelle spectrograph with a 400 mm focal length
ARYELLE ButterflyDual echelle spectrograph, VUV and UV-VIS-NIR
CALIBSOLaboratory LIBS system
CORALISCombined Raman-LIBS system
MNL 100Compact nitrogen laser
MNL 100 HPHigher-power version of the MNL nitrogen laser
qMNL-1000DPSS laser at 336 nm, active Q-switching
Sophi nXtControl software for the measurement systems

Where is LTB Lasertechnik Berlin equipment used?

  • Metallurgy — fast analysis of aluminium and steel alloys
  • Geology and gemology — elemental analysis of mineral samples
  • Technical cleanliness and forensics — particle identification with Raman-LIBS
  • Research — nuclear fusion, MALDI-TOF, laboratory spectroscopy
  • Laser material processing — microstructures and special systems

How do we supply LTB Lasertechnik Berlin in Romania?

We can check and quote LTB products: ARYELLE spectrometers, MNL nitrogen lasers and qMNL-1000 DPSS lasers, as well as CALIBSO and CORALIS systems, starting from the application described. They are supplied to order; depending on the specification, the lead time may be longer, and for components it is usually 1–4 weeks. For a correct request, the following are useful: spectral range, desired resolution, detector type, nature of the samples and mode of integration (component or complete system). Software configuration and calibrations on materials are outside our offer.

The spectrometer or laser from the family that suits the application is determined from the spectral range and the sample type.

Frequently asked questions about LTB Lasertechnik Berlin

What products does LTB Lasertechnik Berlin make?

LTB, from Berlin, develops short-pulse UV lasers (nitrogen and DPSS lasers), ARYELLE echelle spectrometers, LIBS and Raman analysers (CALIBSO, CORALIS) and systems for laser material processing. The company has worked in laser measurement for over 35 years.

How do I choose between ARYELLE 200, 400 and Butterfly?

ARYELLE 200 is the compact version, ARYELLE 400 offers higher resolution, and Butterfly covers the VUV and UV-VIS-NIR ranges simultaneously. The required spectral range and resolution decide; send them to us together with the application. The detector used also influences the final choice.

Do you supply LTB products in Romania, and within what lead time?

Yes. LTB components, such as ARYELLE spectrometers or MNL lasers, are supplied to order; for items the lead time is usually 1–4 weeks. CALIBSO and CORALIS systems are configured for the application, so they may need longer.

Can an MNL nitrogen laser replace another UV laser?

We assess equivalence on the basis of the data. We compare wavelength, pulse energy, frequency and control interface, then say whether an MNL or a qMNL-1000 suits the application. The control interface is also checked before the quotation.

What information do you need for a quotation on a LIBS or Raman system?

The nature of the samples, the elements of interest, the spectral range, the desired resolution, the detector type and whether you need a complete system or only components. If you are replacing an instrument, add its model. For separate components, also state the interface you want.

How do I request a LTB Lasertechnik Berlin quotation?

Send the LTB Lasertechnik Berlin code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: LTB Lasertechnik Berlin GmbH (manufacturer documentation)