MBW Calibration supplier in Romania
Chilled-mirror hygrometers for dew point, calibration and SF6
Founded in 1962 · Headquarters: Wettingen, Switzerland
Who is MBW Calibration and what does it make?
MBW Calibration AG was founded in 1962 and is based in Wettingen, Switzerland. It develops and makes chilled-mirror hygrometers, that is, instruments that directly determine the temperature at which condensation appears on a thermostatted mirror, rather than deducing it from an electrical response. MBW instruments are used as transfer standards in metrology laboratories and in interlaboratory comparisons.
The problem they solve is confidence in a humidity measurement. Sensors that deduce humidity from an electrical response drift more over time; the chilled mirror gives a value with good repeatability and low drift, suitable as a reference. Model 373 covers from −95 °C frost point to +95 °C dew point, with a detachable mirror module for calibration in liquid. Model 573 is the industrial version for continuous measurement, 473 is used for validating climatic chambers, and 973 is portable, for on-site checks.
For the electrical industry there is also the 973-SF6 version: it measures humidity, SF6 purity and, optionally, SO2 concentration in gas-insulated equipment, with an internal system for capturing and returning the sample. MBW makes sense in substations with high-voltage GIS cells, in metrology and calibration laboratories, at humidity sensor manufacturers and in compressed air installations where dryers are checked.
What do we supply from the MBW Calibration range?
| Product | Description |
|---|---|
| Model 373 | Chilled-mirror reference hygrometer, from −95 °C frost point to +95 °C dew point, with two platinum resistance thermometers, a thermostatted sample and a detachable mirror module. For calibration, metrology institutes and research. |
| Model 573 | Industrial chilled-mirror hygrometer for continuous measurement, in three configurations, from −60 °C frost point to +95 °C dew point, with heated versions for dew points above ambient temperature. |
| Model 973 | Portable chilled-mirror hygrometer, with temperature and pressure measurement. Versions are 973L for low range, 973S with built-in pump and 973CA for compressed air or high pressure. |
| Model 973-SF6 | Portable analyser for SF6 gas: humidity (dew point), SF6 purity and, optionally, SO2, with an internal system for capturing and returning the sample, for GIS cells and high-voltage circuit breakers. |
Why MBW Calibration?
- Direct measurement of dew point and frost point — the chilled mirror offers repeatability and low drift, and is the reference used to calibrate other sensors
- Model 373 from −95 °C to +95 °C — covers both very low humidity and dew points above ambient, with a detachable mirror module
- 973-SF6 for gas-insulated equipment — three measurements in one portable instrument, with recovery of the SF6 sample to limit losses to the atmosphere
- A range from field to laboratory — 973 portable, 573 industrial, 473 for climatic chambers, 373 reference, all on the same principle
- Hygrometers used as transfer standards — in metrology laboratories and in interlaboratory comparisons
Which MBW Calibration codes and series are requested most often?
| Code | Description |
|---|---|
| 373 | Chilled-mirror reference hygrometer, −95 °C to +95 °C |
| 473 | Chilled-mirror hygrometer, cable heads, for climatic chambers |
| 573 | Industrial chilled-mirror hygrometer, continuous measurement |
| 973 | Portable chilled-mirror hygrometer |
| 973L | 973 version for low humidity range |
| 973S | Standard 973 version with built-in pump |
| 973CA | 973 version for compressed air and high pressure |
| 973-SF6 | Portable analyser for humidity, SF6 purity and SO2 |
| T12 | Multichannel thermometer for validating climatic chambers |
Where is MBW Calibration equipment used?
- High-voltage substations — humidity and purity of SF6 in GIS cells and circuit breakers
- Metrology and calibration laboratories — reference for dew point and frost point
- Humidity sensor manufacturers — calibration and interlaboratory comparisons
- Climatic testing — validation of climatic chambers and humidity generators
- Compressed air and technical gases — checking of dryers and gas quality
How do we supply MBW Calibration in Romania?
We can quote MBW hygrometers, from the portable models to the reference ones, plus accessories and measuring heads. The equipment is supplied to order, usually in 1–4 weeks, and reference configurations or those with several heads may need more time. For a correct quotation, state the application (field, laboratory, process line or SF6), the dew point and frost point range, the gas pressure, whether you also want SO2 measurement, and the accessories needed. Accessories can ship in 24–72 h when the item is in stock, locally or at the supplier; the final lead time is confirmed in the quotation.
Periodic calibration of the supplied instrument and its interval are clarified case by case before the order.
Frequently asked questions about MBW Calibration
What product range does MBW Calibration have?
Chilled-mirror hygrometers for direct measurement of dew point and frost point: models 373 (reference), 473 (climatic chambers), 573 (industrial) and 973 (portable, including 973-SF6 for gas-insulated equipment). The company is based in Wettingen, Switzerland.
How do I choose the MBW model by application?
For calibration and reference, 373 is used; for validating climatic chambers, 473 together with the T12 thermometer; for continuous measurement in a process, 573; for field checks, 973. In electrical substations with SF6, 973-SF6 is chosen. The dew point range and the gas pressure decide the version.
Do you supply MBW hygrometers in Romania, and how long does it take?
Supply is to order. An MBW hygrometer or measuring head is supplied to order, usually in 1–4 weeks; accessories can ship in 24–72 h when the item is in stock, locally or at the supplier. Reference models and configurations with several heads need a separate lead time.
Can a 973-SF6 replace an existing SF6 analyser?
It depends on what the current instrument measures. 973-SF6 offers humidity, SF6 purity and optionally SO2, with sample recovery. Send us the old model, the connections used at the gas compartment and the required parameters, and we check compatibility before the quotation.
What details should I give for a quotation on a chilled-mirror hygrometer?
The type of gas, the dew point or frost point range, the pressure and flow of the sample, the place of use (laboratory, field, line), whether SF6 or SO2 measurement is needed and the list of accessories wanted, for example measuring heads or the T12 thermometer.
How do I request a MBW Calibration quotation?
Send the MBW Calibration code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Process Insights (manufacturer documentation)