PSG PerfectSampleGas supplier in Romania
Heated sampling probes, heated lines and gas sample coolers
Founded in 1975 · Headquarters: Hochheim am Main, Germany
Who is PSG PerfectSampleGas and what does it make?
PSG, short for PerfectSampleGas, is a German company from Hochheim am Main, near Frankfurt, founded in 1975. It began with air receivers for instrumentation and over time moved on to what it makes today: gas sampling probes, heated sample transport lines, sample coolers and complete conditioning systems, sometimes supplied in an analysis container, including for explosive atmospheres. The company's roughly 40 people work in premises modernised in 2021, and the concept is simple: from the sampling point to the analyser, the sample must remain unchanged.
The PSG Plus and PSG Basic probes filter the sample over an outer surface of 212 cm², open without tools for filter replacement, and the PSG Plus is heated with controlled or self-regulating heating to 180 °C. On the PSG Plus, with one- or two-stage backflushing, permitted dust concentrations reach 40 g/m³ and 280 g/m³ respectively; the PSG Basic is intended for small and medium dust loads. There are variants for DeNOx, with a glass condensate vessel and a peristaltic pump that removes ammonium salts, for explosion-hazard zones (the ATEX 90, 150 and 180 variants, according to the manufacturer's documentation) and, in the Duo series, with two independent outlets for two analysers. Heated lines are made in more than 2500 variants, and the MAK Process C coolers are designed for high flow rates and a lot of water, for example for measuring O2 in H2 in electrolysis.
PSG components are of interest to integrators and CEMS operators: power plants, incinerators, cement works, steelworks, chemical and petrochemical plants, biogas and wastewater treatment plants. The choice is made according to dust content, temperature and acid in the gas, the distance to the analyser and the mounting zone.
What do we supply from the PSG PerfectSampleGas range?
| Product | Description |
|---|---|
| PSG Plus Probe | Heated sampling probes for continuous extractive analysis from hot gases loaded with dust and vapours. They are heated to 180 °C, with tool-free filter replacement and without removing the heated line; variants: DeNOx, ATEX 90, with double backflush and mobile. |
| PSG Basic Probe Duo | Probe for small and medium dust loads, with two independent outlets for splitting the sample between two heated lines and two analysers. The filter is heated under control up to 250 °C or self-regulating at 160–180 °C. |
| PSG Heated Lines | Sample transport lines in more than 2500 versions, so that the gas stays above the dew point of water and acids as far as the conditioning system. The TBX-H PerfectZero series avoids CO being produced by the heater, which matters at small CO ranges. |
| MAK Sample Coolers | Sample gas coolers configurable into complete conditioning systems. The MAK Process C series is modular, for high flow rates and high water concentrations, in safety applications such as monitoring O2 in H2 in electrolysis. |
Why PSG PerfectSampleGas?
- 212 cm² filtration surface — the sample passes through a large filter, suited to gases with dust and moisture
- One- or two-stage backflushing on the PSG Plus — operation at 40 g/m³ and 280 g/m³ of dust respectively
- PSG Plus DeNOx with condensate vessel and peristaltic pump — removes ammonium salts from the condensate
- ATEX 90, 150 and 180 variants and lines with approvals according to the manufacturer's documentation — sampling in explosion-hazard zones
- Heated lines in more than 2500 variants — length, temperature and material are chosen according to the application
Which PSG PerfectSampleGas codes and series are requested most often?
| Code | Description |
|---|---|
| PSG Plus Probe | Heated sampling probe, 180 °C, 212 cm² filter |
| PSG Plus Probe DeNOx | Probe with condensate vessel and SR25 peristaltic pump |
| PSG Plus Probe ATEX 90 | Probe for explosion-hazard zones, heating to 90 °C |
| PSG Plus Probe Double Back Purge | Probe with double backflush |
| PSG Plus Probe Mobile | PSG Plus probe for mobile measurements |
| PSG Basic Probe | Probe for small and medium dust loads |
| PSG Basic Probe Duo | Probe with two independent sample outlets |
| PSG Process Probe ATEX 150 | Process probe for ATEX zones |
| PSG Process Probe ATEX 180 | Process probe for ATEX zones, up to 180 °C |
| PSG HT 250 | Heated sampling tube |
| PSG ST | Sampling tube |
| PSG ST49 | Temperature controller for probes and heated lines |
| PSG PR | Pressure reducing valve for protecting the sampling system |
| TBX-H PerfectZero | Heated line that prevents CO formation |
| MAK Process C | Modular sample cooler for high flow rates |
Where is PSG PerfectSampleGas equipment used?
- Energy and emissions measurement — power plants and incinerators, CEMS with probe and heated line
- Cement industry and steel — sampling from gases with a lot of dust
- Chemicals and petrochemicals — sampling and conditioning, including in ATEX zones
- Biogas and wastewater treatment plants — sample conditioning for process analysers
- Green hydrogen — monitoring O2 in H2 at electrolysers
How do we supply PSG PerfectSampleGas in Romania?
We can prepare quotations for PSG Plus and Basic probes, heated lines, MAK coolers and PSG conditioning systems. Components are supplied to order; the lead time is usually 1–4 weeks, and complete systems or analysis containers, configured per project, may need more. For a correct quotation we need the gas temperature and pressure, the content of dust, vapours and acids or ammonia, the line length, the analyser served, the electrical supply available and the mounting zone (safe or explosion-hazard). For replacement parts, send the code from the nameplate. The exact configuration is confirmed in the quotation.
The length and connection type of a heated line for a given route are determined from a sketch of the route, which is needed before the quotation.
Frequently asked questions about PSG PerfectSampleGas
What products does PSG PerfectSampleGas make?
PSG, from Hochheim am Main, makes heated gas sampling probes (PSG Plus and PSG Basic), heated lines in more than 2500 variants, MAK sample coolers and complete conditioning systems, sometimes in an analysis container, for CEMS and process analysis.
How do I choose between the PSG Plus, Basic and Duo for a stack?
The PSG Plus is the choice for gases with a lot of dust and moisture, with two-stage backflushing up to 280 g/m³; the Basic suits small and medium dust loads; the Duo has two outlets for two analysers. Send us the dust content, the temperature and the list of analysers.
Can I order PSG components for an installation and within what time?
Yes, to order. For probes and lines the lead time is usually 1–4 weeks, and complete systems or containers may need more. The exact time is set in the quotation, according to the type of parts.
Can an existing probe or heated line be replaced with a PSG one?
It is analysed case by case, according to flange, length, supply voltage and connections. Equivalence is confirmed only after checking; send the make and code of the current part, the length, the working temperature and the tube diameter, and we determine which PSG variant fits.
What details should I send for a sampling probe quotation?
State the gas temperature and pressure, the dust concentration, the presence of water vapour, acids or ammonia (DeNOx), the diameter and flange of the stack opening, the line length to the analyser and the mounting zone. For Ex zones, give the required class.
How do I request a PSG PerfectSampleGas quotation?
Send the PSG PerfectSampleGas code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: AGT-PSG GmbH & Co. KG (manufacturer documentation)