Who is Signal Group and what does it make?

Signal Group is a British manufacturer of gas analysers headquartered in Camberley, active for almost five decades. It builds its instruments in the United Kingdom, on the principle that an analyser must work for well over a decade, and besides the instrument itself it takes on the whole measuring chain: sample extraction, conditioning, calibration and system integration. The S4 range brings together different detectors for the same industrial problems: hydrocarbons, nitrogen oxides, ammonia, gases measured in the infrared and oxygen.

S4 SOLAR is a heated FID analyser for VOC, in a 19-inch rack, with a dual-detector version for the simultaneous measurement of methane and non-methane hydrocarbons; S4 SOLAR XPLORE is the portable version, with a detachable tablet, and 3010 MINIFID is a portable heated FID, with a 5 m sample line. S4 QUASAR uses heated vacuum chemiluminescence for NO, NOx, NO2 or ammonia, S4 NEBULA measures ammonia by tunable diode laser spectroscopy (TDLS), between 0–100 ppm and 0–10,000 ppm, and S4 PULSAR is a multi-gas NDIR with a detector that eliminates cross-sensitivity. S4 AURORA is the paramagnetic oxygen analyser. SOLAR CEMNEX combines the FID, heated sample handling and automatic calibration in a rack system with measurement approvals specified in the manufacturer's documentation for 15, 30 and 500 mg/m³.

These analysers are used on stacks with VOC limits, on boilers and combustion processes, in DeNOx installations, in fertiliser production and in emissions laboratories. The choice depends on the gases and ranges measured, on whether the instrument is fixed or portable and on the certification required.

What do we supply from the Signal Group range?

ProductDescription
S4 SOLAR and S4 SOLAR XPLOREHeated FID analysers for VOC, in a 19-inch rack (SOLAR) or portable (XPLORE, with a detachable tablet and an optional zero-air generator). There are versions with two detectors for methane and non-methane hydrocarbons.
SOLAR CEMNEXSingle system for total hydrocarbons and VOC in applications with strict compliance: S4 SOLAR FID, heated sample handling and automatic calibration, in a rack, for continuous unattended operation. Measurement approvals indicated in the manufacturer's technical documentation for 15, 30 and 500 mg/m³.
S4 QUASAR and S4 NEBULAQUASAR is a heated vacuum chemiluminescence analyser for NOx, NO, NO2 or ammonia; NEBULA measures ammonia by TDLS, in application mode or laboratory mode, depending on the humidity of the sample.
S4 PULSAR and S4 AURORAPULSAR is a multi-gas NDIR analyser (CO, CO2, SO2) with a correlation filter and very low drift, for low ranges. AURORA is a paramagnetic oxygen analyser, with remote control by software and an optional wireless tablet.

Why Signal Group?

  • S4 SOLAR with dual detector — measures methane and non-methane hydrocarbons simultaneously in a single rack
  • SOLAR CEMNEX with measurement approvals according to the manufacturer's documentation for 15, 30 and 500 mg/m³ — integrated system from probe to data output, for regulated VOC
  • Complete measuring chain — extraction, conditioning, calibration and integration, not only the analyser
  • S4 NEBULA TDLS for ammonia — 0–100 ppm or 0–10,000 ppm, useful in DeNOx and for injection control
  • Instruments designed for operation of over a decade — long service life pursued from the design stage

Which Signal Group codes and series are requested most often?

CodeDescription
S4 SOLARHeated FID analyser for VOC, 19-inch rack
S4 SOLAR XPLOREPortable heated FID analyser, detachable tablet
3010 MINIFIDPortable heated FID, 5 m sample line
SOLAR CEMNEXTHC/VOC system with approvals specified in the manufacturer's documentation
S4 QUASARHeated vacuum chemiluminescence, NOx
S4 NEBULATDLS ammonia analyser
S4 PULSARMulti-gas NDIR analyser
S4 GHG PULSARGHG version of the PULSAR analyser
S4 AURORAParamagnetic oxygen analyser
VCLDQUASAR version with NOx converter
TDLS-NH3 A0–100 ppm range for NEBULA
TDLS-NH3 B0–10,000 ppm range for NEBULA

Where is Signal Group equipment used?

  • Stacks and processes with VOC limits — heated FID for total hydrocarbons and methane
  • DeNOx installations and power plants — ammonia and NOx in flue gases
  • Fertiliser production — NH3 in processes and emissions
  • Combustion and combustion efficiency — paramagnetic oxygen and CO
  • Emissions laboratories — portable FID for periodic measurements

How do we supply Signal Group in Romania?

We can prepare quotations for Signal Group analysers from the S4 range, for the 3010 MINIFID portable FID and for SOLAR CEMNEX systems. The equipment is supplied to order; the analysers are configured per application, and the lead time to order is usually 1–4 weeks and can be longer for systems with probe and conditioning. For a correct quotation we need the gas and the range to be measured, the type of analyser wanted (rack or portable), the temperature and humidity of the sample, the internal pumps required and whether the measurement is regulated (MCERTS). The configuration and the lead time are confirmed in the quotation.

Configurations with multiple options, for pump, calibration gases and interfaces, are confirmed once the full specification has been defined.

Frequently asked questions about Signal Group

What products does Signal Group make?

Signal Group makes gas analysers in the United Kingdom, at Camberley: S4 SOLAR and 3010 MINIFID (FID for VOC), S4 QUASAR (NOx), S4 NEBULA (TDLS ammonia), S4 PULSAR (multi-gas NDIR) and S4 AURORA (oxygen), plus the integrated SOLAR CEMNEX system.

How do I choose between S4 SOLAR and SOLAR CEMNEX?

S4 SOLAR is the FID analyser itself; SOLAR CEMNEX is the complete system for regulated emissions, with a probe, heated sample handling and automatic calibration, with measurement approvals specified in the manufacturer's documentation for ranges such as 15 mg/m³. Send us the emission limit and the installation site.

Can you supply Signal analysers in Romania and how soon?

Yes, we supply the instruments to order. For analysers the lead time to order is usually 1–4 weeks, and complete systems, with probe and conditioning, may need longer. The exact lead time appears in the quotation.

Can I replace an older FID analyser with an S4 SOLAR?

It is analysed according to the current model, the range, the output signals and the sample line. Equivalence is confirmed only after checking. Send the make, model and series of the old instrument, the calibration gas used and whether it is rack-mounted or portable.

What information do you need for a quotation on an S4 analyser?

State the gas to be measured and the range (for example VOC in ppm or mg/m³), whether the instrument is fixed or portable, the temperature and humidity of the sample, the sample pump wanted, the calibration and whether the measurement requires MCERTS certification. For ammonia, also give the moisture content of the gas.

How do I request a Signal Group quotation?

Send the Signal Group code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: Signal Group (manufacturer documentation)