Spectruma Analytik supplier in Romania
GDOES spectrometers for depth profile and composition
Headquarters: Hof, Germany
Who is Spectruma Analytik and what does it make?
Spectruma Analytik GmbH, based in Hof, Germany, is a manufacturer specialising in glow discharge spectrometers (GDOES, glow discharge optical emission spectrometry). The method measures both the bulk composition of solid materials and the depth profile, that is, the variation of the elements from the surface inwards, layer by layer. For a steelworks, a coatings producer or a research laboratory, this means being able to check the thickness and composition of thin layers, thermochemical treatments and metallic coatings, without complicated sample preparation.
The GDA range covers several levels. GDA-Alpha is the compact benchtop instrument with high-resolution CCD optics, intended for production control, quality assurance and goods-in inspection of materials. GDA 150 HR is a robust instrument for conductive samples, designed for 24/7 operation and for small and medium-sized heat-treatment and coating companies; it can also analyse light elements such as C, N and H, as an option. GDA 650 HR analyses conductive and non-conductive samples, with CCD technology and a direct optical path, for minimal transmission losses. GDA 750 HR is the modular model, intended for research and development, with up to 79 channels with photomultiplier tubes, able to analyse conductive and non-conductive samples. The options include high-resolution CCD optics, monochromator, universal sample unit, autosampler, sample transfer chamber, external plasma ignition and chiller.
The instruments are of interest to steel and coated sheet producers, heat-treatment and galvanising companies, research laboratories and those in the automotive and electrical industries. The choice starts from the type of samples (conductive or not), the depths of interest and the elements required.
What do we supply from the Spectruma Analytik range?
| Product | Description |
|---|---|
| GDA-Alpha | Compact benchtop GDOES spectrometer with high-resolution CCD optics. It measures the thickness and weight of ultrathin layers and the composition of coatings, substrates and bulk materials. It is suitable for production control, quality assurance and goods-in inspection. |
| GDA 150 HR | Robust, thermostatted GDOES spectrometer for conductive samples, useful in quality control and research. It can also analyse C, N, H, as an option, and runs continuously. It is intended for small and medium-sized heat-treatment and coating companies. |
| GDA 650 HR | GDOES spectrometer for conductive and non-conductive samples, with CCD technology and a direct optical path. Used in quality control and research, with easy maintenance. The instrument is built for continuous operation and has a direct optical path, with minimal transmission losses. |
| GDA 750 HR | Modular GDOES spectrometer, with up to 79 photomultiplier channels, for difficult research and development applications, with analysis of conductive and non-conductive samples. The modular configuration allows adaptation to the requirements of each laboratory. |
Why Spectruma Analytik?
- Depth profile and bulk composition from the same instrument — checking thin layers and coatings
- GDA 650 HR and GDA 750 HR analyse conductive and non-conductive samples — wider coverage of materials
- GDA 750 HR with up to 79 photomultiplier channels — suited to research and difficult applications
- GDA 150 HR for continuous 24/7 operation at heat-treatment and coating companies — and with C, N and H as an option
- Modular options (autosampler, transfer chamber, monochromator) — configuration according to the laboratory's application
Which Spectruma Analytik codes and series are requested most often?
| Code | Description |
|---|---|
| GDA-Alpha | Compact benchtop GDOES spectrometer |
| GDA 150 HR | GDOES for conductive samples, 24/7 operation |
| GDA 550 HR | GDOES model from the GDA HR series |
| GDA 650 HR | GDOES for conductive and non-conductive samples |
| GDA 750 HR | Modular GDOES, up to 79 channels |
Where is Spectruma Analytik equipment used?
- Steel and coated sheet — depth profile and layers
- Automotive industry — coatings and surface treatments
- Electrical industry — thin layers and contacts
- Aerospace — coatings and advanced materials
- Research — elemental analysis and layer thickness
How do we supply Spectruma Analytik in Romania?
We can check and quote Spectruma spectrometers from the GDA series, plus options (autosampler, transfer chamber, monochromator, chiller) and consumables. The instruments are supplied to order; depending on the specification, the lead time may be longer, and for consumables it is usually 1–4 weeks. For a correct quotation the following are useful: the type of samples (conductive or non-conductive), the layers and depths of interest, the elements required (including C, N, H) and the number of samples per day.
Whether a GDA model covers the required analysis is determined from the sample and layer data.
Frequently asked questions about Spectruma Analytik
What products does Spectruma Analytik make?
Spectruma Analytik, from Hof, makes GDOES spectrometers from the GDA series (GDA-Alpha, GDA 150 HR, 650 HR, 750 HR) for bulk and depth profile analysis of solid materials, with options for optics, samples and plasma.
How do I choose between GDA 150 HR, 650 HR and 750 HR?
GDA 150 HR targets conductive samples and continuous operation, 650 HR adds non-conductive samples, and 750 HR is the modular model for research. The type of samples and the elements required decide; send them to us. The depth of the layers of interest is also a criterion.
Do you supply Spectruma spectrometers in Romania, and within what lead time?
Yes. Consumables and options for the GDA series are supplied to order, usually in 1–4 weeks. A configured GDOES spectrometer, with an autosampler or transfer chamber, has a longer lead time, set in the quotation.
Can GDOES replace my current method for layers?
We assess equivalence on the basis of the data. We compare layer thickness, materials and the precision required, then say whether a GDA model suits the analysis or whether the current method remains more suitable. The conclusion is formulated before the quotation, after analysing the data sent.
What data do you need for a quotation on a GDA spectrometer?
The type of samples, the layers and depths, the elements (including C, N, H), the number of samples per day and the options wanted. For replacements, add the model and serial number of the current instrument. The estimated layer thickness and the base material complete the information needed.
How do I request a Spectruma Analytik quotation?
Send the Spectruma Analytik code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Spectruma Analytik GmbH (manufacturer documentation)