Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Tiger Optics supplier in Romania

CRDS laser analyzers for moisture and impurities in ultra-pure gases

Founded in 2001

Request a quote

Who is Tiger Optics and what does it make?

Tiger Optics makes laser gas analyzers based on cavity ring-down spectroscopy (CRDS), supplemented in some models by quantum cascade lasers. The company was founded in 2001. The principle is simple to explain to a process engineer: laser light bounces thousands of times between two highly reflective mirrors, and the impurity molecules absorb part of it and shorten the “ring-down” time of the signal. From this time the concentration results, in ppb or even ppt, without calibration gas.

The range is grouped into families. HALO 3 measures moisture, CO, CO2, CH4, NH3, HCl or HF, one species per unit; HALO KA Max goes down to detection limits of 100 ppt for moisture; HALO Max QCL tracks CO and CO2 at ppt level; Prismatic 3 measures H2O, CO, CO2 and CH4 simultaneously at ppb and is used for hydrogen purity checks according to SAE J2719 and ISO 14687:2019; T-I Max EtO tracks ethylene oxide.

Such analyzers are needed in air separation plants and at producers of nitrogen, hydrogen and special gases, in gas control laboratories and in electronic component factories. For a unit already in operation, the model and serial number on the analyzer give the starting point.

What do we supply from the Tiger Optics range?

ProductDescription
HALO 3A family of CRDS analyzers with one species per unit: moisture, CO, CO2, CH4, NH3, HCl, HF, CH2O or D2O/HDO. Used for quality control of bulk gases, on mobile analysis carts, in air separation and for checking cylinders.
HALO KA MaxCRDS platform for moisture (detection limit down to 100 ppt), ammonia and methane, with fast response, long-term stability and internal zero check.
HALO Max QCLAnalyzers with a quantum cascade laser for CO and CO2 at ppt level in ultra-pure gases, from the same Max platform.
Prismatic 3Multi-species CRDS analyzer for H2O, CO, CO2 and CH4 from ppb to ppm, with a touch screen, created for checking the purity of hydrogen in the fuel cell supply chain.

Why Tiger Optics?

  • CRDS with absolute measurement — no calibration gases are needed, which simplifies operation
  • HALO KA Max H2O with a detection limit down to 100 ppt — for very high purity gases and moisture-sensitive processes
  • Prismatic 3 on four species — H2O, CO, CO2 and CH4 from ppb to ppm, suitable for checking the purity of hydrogen for fuel cells
  • HALO Max QCL for CO and CO2 — detection at ppt level with a quantum cascade laser, internal zero check
  • Applications in inert, corrosive and toxic gases — HALO 3 H2O measures moisture in most inert, corrosive and toxic gases with the same type of unit

Which Tiger Optics codes and series are requested most often?

CodeDescription
HALO 3 H2OCRDS analyzer for moisture in inert, corrosive and toxic gases
HALO 3 COCRDS analyzer for carbon monoxide
HALO 3 CO2CRDS analyzer for carbon dioxide
HALO 3 CH4CRDS analyzer for methane
HALO 3 NH3CRDS analyzer for ammonia
HALO 3 HClCRDS analyzer for hydrochloric acid
HALO 3 HFCRDS analyzer for hydrofluoric acid
HALO KA Max H2OMoisture analyzer with detection down to 100 ppt
HALO KA Max NH3KA Max variant for ammonia
HALO KA Max CH4KA Max variant for methane
HALO Max QCL COQCL analyzer for CO at ppt level
HALO Max QCL CO2QCL analyzer for CO2 at ppt level
HALO H2CRDS analyzer for trace hydrogen in high-purity gases
Prismatic 3Multi-species analyzer H2O, CO, CO2 and CH4
T-I Max EtOAnalyzer for trace ethylene oxide

Where is Tiger Optics equipment used?

  • Industrial gases — air separation plants and nitrogen factories
  • Hydrogen — purity control along the production, transport and fuelling chain
  • Special and medical gases — impurities in inert, reactive and corrosive gases
  • Electronics and semiconductors — moisture and contaminants in process gases
  • Chemicals and sterilisation — monitoring of ethylene oxide in installations

How do we supply Tiger Optics in Romania?

You can request a quotation for Tiger Optics CRDS analyzers or for parts and accessories associated with an analyzer already installed. We supply to order; the lead time is usually 1–4 weeks, longer for analyzers configured for corrosive or toxic gas or for low pressure. For a quotation we need the species to be measured (moisture, CO, CO2, CH4, NH3, HCl, HF, ethylene oxide), the concentration range, the carrier gas (nitrogen, hydrogen, argon, air, corrosive gas), the inlet pressure and the installation area. Accessories can ship in 24–72 h when the item is in stock, locally or at the supplier; the final confirmation appears in the quotation.

The detection limit on a given gas is established after checking the combination of species, carrier gas and pressure.

Frequently asked questions about Tiger Optics

What range of products does Tiger Optics have?

Laser gas analyzers based on cavity ring-down spectroscopy (CRDS), for moisture, CO, CO2, CH4, NH3, HCl, HF and ethylene oxide, at ppb and ppt level. The company was founded in 2001.

How do I choose between HALO 3 and HALO KA Max for moisture?

HALO 3 H2O is a versatile analyzer for most inert, corrosive and toxic gases; HALO KA Max H2O goes down to detection limits of 100 ppt and suits very high purity gases. The moisture level to be tracked and the background gas decide the model.

Do you supply Tiger Optics analyzers in Romania?

We supply the analyzers to order. A HALO or Prismatic analyzer arrives to order, usually in 1–4 weeks, and accessories can ship in 24–72 h when the item is in stock, locally or at the supplier; versions for corrosive or toxic gas are configured separately.

Can a CRDS analyzer replace my current moisture sensor?

The replacement is confirmed after checking. We need the gas measured, the moisture range, the sample pressure, the connection and the output signal currently used, to see whether a HALO can be fitted at the same point.

What details are needed for a Prismatic 3 quotation?

The application (for example hydrogen control for fuel cells), the species and levels of interest, the standard followed (SAE J2719 or ISO 14687), the sample inlet pressure and the interface wanted to the monitoring system.

How do I request a Tiger Optics quotation?

Send the Tiger Optics code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Process Insights (manufacturer documentation)