Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Unisearch Associates supplier in Romania

LasIR TDLAS and DOAS laser analysers for NH3, HCl, HF and flue gases

Founded in 1980 · Headquarters: Concord, Canada

Request a quote

Who is Unisearch Associates and what does it make?

Unisearch Associates Inc. is a Canadian company from Concord, Ontario, founded in 1980, which develops gas analysers based on tunable diode laser absorption spectroscopy (TDLAS) and differential optical absorption in the ultraviolet (DOAS). It started with research and instruments for air-quality measurements, then moved on to remote-sensing systems and in-situ instruments for emissions, and today its instruments are used for process control and for regulated measurement.

The LasIR family uses telecom-grade lasers mounted on a thermoelectric cooler, and comes in four configurations: in-situ at the stack, extractive, portable and open-path perimeter monitoring. The instrument measures flue gases for compliance and for the process, with up to thirty-two 4–20 mA analogue outputs, Ethernet, MODBUS and status relays. For ammonia and water, HCl and water, HF and their combinations there are versions with approvals according to the manufacturer's documentation, and the in-situ configuration is indicated for EN 14181. For multi-component measurements, DOAS measures several species in a single unit, either in the stack, when dust is low and the optical path is no more than a few metres, or extractively.

Instruments designed in this way are of interest to power plants with SCR or SNCR, where ammonia slip is monitored continuously, to incinerators and plants with HCl, to cement plants, refineries and fertiliser factories. The choice is made according to the gas to be measured, the optical path, the dust in the stack and the certification required.

What do we supply from the Unisearch Associates range?

ProductDescription
LasIR in-situTDL flue gas monitor mounted in the stack, with approvals according to the manufacturer's documentation, and for process control. It can measure several components at once at different points, with an internal reference cell or an external audit module.
LasIR extractiveThe extractive version of the LasIR analyser, for gases where measurement in the stack is not possible, with an in-line flow-through cell for checks and with the same analogue outputs, MODBUS and relays as the in-situ version.
LasIR portable and perimeterThe portable version is compact and weatherproof, for open-path measurements and in ambient air, with internal memory, while the perimeter version monitors an open path with a retroreflector; both use the same TDL laser.
DOAS in-situ and extractiveUV differential absorption instruments, for several species in one unit. The in-situ configuration is for stacks with little dust and a path of a few metres; the extractive one has an internal or external flow-through cell, with optical fibres of up to a few tens of metres.

Why Unisearch Associates?

  • TDLAS with low interference from other gases — the absorption line chosen is specific, so background gases have little influence on the measurement
  • Versions with measurement approvals according to the manufacturer's documentation for NH3 and H2O, HCl and H2O, and HF — for plants with SCR, incinerators and cement
  • Four LasIR configurations — in-situ, extractive, portable and perimeter, on the same platform
  • Flexible outputs — up to 32 analogue 4–20 mA outputs, Ethernet, MODBUS TCP and RTU and status relays
  • Factory test supplied with each instrument — and audit options with an internal reference cell or an external module

Which Unisearch Associates codes and series are requested most often?

CodeDescription
LasIR in-situIn-stack TDL monitor, PS-18 and EN 14181
LasIR extractivExtractive TDL gas analyser
LasIR portablePortable TDL analyser, open path
LasIR perimetruOpen-path perimeter monitoring
NH3 + H2O QAL 1Ammonia and water analyser, with measurement approvals specified in the manufacturer's documentation
HCl + H2O QAL 1HCl and water analyser, with measurement approvals indicated in the manufacturer's technical documentation
HF QAL 1HF analyser, with measurement approvals according to the manufacturer's documentation
HF + HCl + H2O QAL 1Combined analyser, with measurement approvals according to the manufacturer's documentation
DOAS in-situIn-stack UV monitor for low dust
DOAS extractivDOAS system with flow-through cell
External audit moduleFlow-through cell for checking the analyser

Where is Unisearch Associates equipment used?

  • Power plants with SCR or SNCR — ammonia slip and water vapour, with LasIR in a version with approvals specified in the manufacturer's documentation
  • Incinerators and plants with HCl — HCl and H2O, HF and combinations, in the stack
  • Cement and steel industry — acid gases and moisture in dusty processes
  • Refineries, petrochemicals and fertilisers — H2S, NH3, BTEX and other gases, by TDL and DOAS

How do we supply Unisearch Associates in Romania?

We can prepare quotations for the Unisearch Associates LasIR and DOAS analysers. We supply the equipment to order; as these are analysers configured for the application, the lead time may be longer and is confirmed in the quotation, while for standard units it is usually 1–4 weeks to order. For a correct quotation we need the gases to be measured and their ranges, the temperature, humidity and dust in the stack, the length of the optical path or the stack diameter, the configuration wanted (in-situ, extractive, portable or perimeter) and the certification required, for example QAL 1. For integration with your system, state the output signals needed.

Periodic recalibration and consumable parts are clarified with each order, on the basis of the manufacturer's documentation.

Frequently asked questions about Unisearch Associates

What products does Unisearch Associates make?

Unisearch Associates, from Concord, Ontario, has made laser gas analysers (LasIR, TDLAS) and ultraviolet differential absorption analysers (DOAS) since 1980, for process control and for regulated emissions, in in-situ, extractive, portable and perimeter configurations.

How do I choose between LasIR and DOAS for my gas?

LasIR uses a single absorption line, so it is suited to a precise target gas (NH3, HCl, HF, H2S), with low interference. DOAS measures several species in one unit, but requires knowing the composition of the gas. Send us the gases, the ranges and the optical path available.

Can you supply Unisearch analysers in Romania, and in what lead time?

Yes, to order. The lead time to order is usually 1–4 weeks, but analysers configured for the application can take longer; the exact lead time is confirmed in the quotation, after the data received has been checked.

Can I replace an existing ammonia slip analyser with a LasIR?

It can be analysed, but it depends on the optical path, the existing flanges and the signals to the acquisition system. We confirm equivalence after checking; send the make and model of the current analyser, the path length and the NH3 range, so we can see which configuration fits.

What data do you need for a quotation on a LasIR analyser?

State the gases and ranges to be measured, the temperature, humidity and dust in the stack, the stack diameter or the optical path, the configuration wanted, the certification required (for example QAL 1) and the output signals needed. For SCR also state the load of the plant.

How do I request a Unisearch Associates quotation?

Send the Unisearch Associates code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Unisearch Associates Inc. (manufacturer documentation)