Andor Technology supplier in Romania
For Andor we offer Kymera 193i and 328i, Shamrock 500i and 750 and Mechelle 5000 spectrographs, plus iStar, iDus, Newton and Marana cameras; for a quotation we need the technique (LIBS, Raman, OES), the spectral range and the resolution desired.
Founded in 1989 · Headquarters: Belfast, Northern Ireland, United Kingdom
Who is Andor Technology and what does it make?
Andor Technology is a British manufacturer of spectrographs, scientific cameras and detectors for spectroscopy, based in Belfast, Northern Ireland, and active since 1989. For industry, the relevant part is the optical measurement chain: the spectrograph splits the light emitted or scattered by a sample by wavelength, and a sensitive detector, sometimes synchronised at the nanosecond level with a laser, records the spectrum. The same chain is used in Raman spectroscopy, in luminescence, in optical emission analysis (OES) and in LIBS, the technique in which a laser pulse creates a plasma on the sample surface and the elemental composition is read.
The spectrograph families cover different needs. Kymera 193i and 328i are modular spectrometers with a focal length of 193 and 328 mm respectively, with a turret for four diffraction gratings, dual input and output ports and adaptive focus. Shamrock 500i and 750 have focal lengths of 500 and 750 mm, for fine spectral resolution. Mechelle 5000 is an echelle spectrograph with no moving parts, which records the range from 200 to 975 nm simultaneously and is supplied pre-aligned together with the detector. On the detection side, iStar is the intensified camera with an optical gate under 2 ns, used to isolate atomic emission from the plasma's continuous background, while iDus, Newton and Marana cover routine spectroscopy, from UV to near infrared.
In industry, typical applications are: a LIBS analysis line built by an integrator, a laboratory bench for Raman or OES, or a system for diagnosing plasma or combustion processes. The choice depends on the spectral range, the resolution needed and the detector speed, while the Solis software and the development kit allow integration into your own application.
What do we supply from the Andor Technology range?
| Product | Description |
|---|---|
| Kymera 193i and Kymera 328i | Modular optical spectrometers with a focal length of 193 mm (F/3.6) and 328 mm (F/4.1), with gratings from 150 to 2400 lines/mm, dual input and output ports, a four-position turret and adaptive focus. They are used for Raman, luminescence, OES and LIBS. |
| Shamrock 500i and Shamrock 750 | Spectrographs with a focal length of 500 mm (F/6.5) and 750 mm (F/9.7), for fine spectral resolution, with dual inputs and outputs. They are chosen when very close spectral lines must be separated or when the resolution of shorter spectrographs is not enough. |
| Mechelle 5000 | Echelle spectrograph with no moving parts, which records the 200–975 nm range simultaneously, with a patented optical design, automatic temperature correction and nitrogen purging for UV transmission. It is supplied pre-aligned together with the detector. |
| iStar, iDus, Newton and Marana | Cameras for spectroscopy. iStar is the intensified version, with a gate under 2 ns, in CCD 320, 334, 340 and sCMOS versions, for LIBS and plasma; iDus covers UV–NIR and near infrared (InGaAs), Newton and Marana work on fast transients and mapping. |
Why Andor Technology?
- Kymera 193i and 328i with adaptive focus and a four-grating turret — several spectral configurations on the same instrument, without realignment
- Mechelle 5000 echelle, 200–975 nm in a single acquisition — all lines of interest in one spectrum, with no moving parts in the optical path
- iStar with an optical gate under 2 ns — separates the atomic emission of the LIBS plasma from the continuous background, essential for trace element analysis
- Shamrock 500i and 750 — long focal lengths for fine spectral resolution, for tasks such as closely spaced lines in an alloy spectrum
- Solis software and development kit — acquisition and integration into your own analysis or process control application
Which Andor Technology codes and series are requested most often?
| Code | Description |
|---|---|
| Kymera 193i | Modular spectrometer, 193 mm, F/3.6 |
| Kymera 328i | Modular spectrometer, 328 mm, F/4.1 |
| Shamrock 500i | 500 mm spectrograph, F/6.5 |
| Shamrock 750 | 750 mm spectrograph, F/9.7 |
| Mechelle 5000 (ME5000) | Echelle spectrograph, 200–975 nm simultaneously |
| iStar CCD 320 | Intensified gated camera, 1024 × 256 pixels |
| iStar CCD 334 | Intensified gated camera, 1024 × 1024 pixels |
| iStar CCD 340 | Intensified gated camera, 2048 × 512 pixels |
| iStar sCMOS | Intensified gated camera, 2560 × 2160 pixels |
| iDus 401 | TE-cooled CCD camera for spectroscopy |
| iDus 420 | TE-cooled CCD camera for UV–NIR and Raman |
| iDus InGaAs 1.7 | InGaAs camera for near infrared, up to 1.7 µm |
| iDus InGaAs 2.2 | InGaAs camera for near infrared, up to 2.2 µm |
| Newton EM/CCD | Fast camera for transients and chemical mapping |
Where is Andor Technology equipment used?
- Metallurgy and materials — LIBS and OES elemental analysis in installations built by integrators
- Applied research and laboratories — Raman spectroscopy, luminescence and absorption
- Energy and fusion — plasma diagnostics and surface analysis by LIBS
- Combustion and fluid mechanics — time-resolved measurements, with gated cameras
- Renewable energy — optical characterisation of materials
How do we supply Andor Technology in Romania?
We can quote Andor spectrographs from the Kymera, Shamrock and Mechelle families, together with iStar, iDus, Newton or Marana cameras and mounting accessories. Andor Technology items are supplied to order, usually in 1–4 weeks, and depending on the specification the lead time may be longer, which is confirmed in the quotation. For a correct request send the technique used (LIBS, Raman, OES), the spectral range, the resolution sought, the type of laser and, for an existing system, the model and serial number of the instrument.
The compatibility of a camera with a spectrograph already installed in another manufacturer's system is determined on the basis of the exact model of both instruments.
Frequently asked questions about Andor Technology
What does Andor Technology make?
Andor makes in Belfast spectrographs and spectrometers (Kymera, Shamrock, Mechelle), scientific cameras for spectroscopy (iStar, iDus, Newton, Marana, iXon) and acquisition software. They are the components of an optical chain used in LIBS, OES, Raman and plasma diagnostics.
How do I choose between a Kymera and a Mechelle spectrograph?
Kymera is a spectrometer with interchangeable gratings, suitable when the range changes from one measurement to another. Mechelle 5000 records 200–975 nm simultaneously, with no moving parts, so it is chosen when elements from distant ranges are followed in the same acquisition. Send us the technique and the list of lines.
Do you bring Andor spectrographs to Romania and how fast?
Yes, supplied to order: Andor Technology items usually arrive in 1–4 weeks. Depending on the specification, the lead time may be longer; the date is confirmed in the quotation, after we establish the complete configuration with the detector and accessories.
Why iStar cameras for a LIBS application?
In LIBS, the plasma first emits an intense continuous background and only then the atomic lines. The iStar's optical gate of under 2 ns opens the detector only in the useful window, so the lines are seen more cleanly. For a quotation we need to know the laser, the delay desired and the spectral range.
What data do I need to send for a quotation on an Andor spectrograph?
Send the measurement technique, the spectral range, the resolution needed, the type of detector if you already have one and the software interface desired. For a part for an existing system, add the model and serial number of the spectrograph, so that we can check compatibility before the quotation.
How do I request a Andor Technology quotation?
Send the Andor Technology code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Andor Technology, Wikipedia (manufacturer documentation)