Cerex Monitoring Solutions supplier in Romania
Multi-gas FTIR and UV-DOAS analysers for perimeter, stack and process
Founded in 1994 · Headquarters: Atlanta, USA
Who is Cerex Monitoring Solutions and what does it make?
Cerex Monitoring Solutions, LLC is an American company based in Atlanta, Georgia, that designs and manufactures multi-gas analysers based on Fourier transform infrared spectroscopy (FTIR) and differential optical absorption in the ultraviolet (UV-DOAS). The company's beginnings date from 1994, when the open-path AirSentry FTIR remote sensing system was developed. Since then the range has expanded to portable point analysers, fixed stack emission installations and process analysers, and each instrument can measure tens or hundreds of compounds simultaneously, from combustion gases to VOCs.
The technical advantage is the absence of routine calibrations and the retention of raw spectra: the in-house software reads measurements every 5–30 seconds and archives spectrographic data for up to a year, which allows an event to be reanalysed later. AirSentry monitors paths from 1 to 1,000 metres, so it covers a perimeter without point sensors. The FT-5000 series measures in the stack, in a crossed arrangement or with a probe, for more than 350 compounds from the FTIR library, while UV3000, Aeres and UV Scout are aimed at benzene, toluene and xylenes (BTEX), ammonia, chlorine and sulphur dioxide.
Solutions of this type are of interest to refineries and petrochemical platforms that must monitor the perimeter for VOCs, chemical and fertiliser plants with NH3 or SO2 emissions, flue gas cleaning installations with DeSOx or DeNOx, and response teams for accidental releases. The choice depends on the target gases, the detection limits, the measurement configuration (open path, point, in-stack) and the requirements of the environmental permit.
What do we supply from the Cerex Monitoring Solutions range?
| Product | Description |
|---|---|
| AirSentry FTIR | Open-path remote sensing analyser with FTIR spectroscopy, for measurement from sub-ppb level up to percent, over paths of 1 to 1,000 metres. It is used for monitoring perimeters, industrial installations and accidental releases. |
| FT-5000 series | FTIR analysers for continuous emissions and processes: in-stack crossed-path, probe or hybrid UV-DOAS/FTIR configurations, able to measure more than 350 compounds simultaneously, without sampling from the stack. Supplied standard or fully customised. |
| UV3000 series | UV-DOAS analysers for process and stack, with crossed-path, rack, probe and area configurations. They measure combustion gases, BTEX, semi-volatile organic compounds, chlorine, ammonia and sulphur dioxide, with limits in ppb; the probe model suits DeSOx and DeNOx applications. |
| Shepherd FTIR | Portable FTIR analyser, cryogenically cooled without liquid nitrogen, for laboratory-grade measurements in the field, with real detection limits in ppb, bands between 2 and 14 microns and a three-year service cycle. Useful for air toxics and refinery monitoring. |
Why Cerex Monitoring Solutions?
- Open-path AirSentry FTIR, 1–1,000 m — perimeter monitoring without a network of point sensors
- No routine calibrations on the FTIR analysers — no zero and span gases are required, only usual consumables
- Raw spectra archived for up to a year — events can be reanalysed after they have occurred
- More than 350 compounds in the FTIR library — a single measurement covers combustion gases, VOCs and acids
- UV-DOAS with detection limits in ppb — for BTEX, NH3, Cl2 and SO2, without interference from water vapour
Which Cerex Monitoring Solutions codes and series are requested most often?
| Code | Description |
|---|---|
| AirSentry FTIR | Open-path remote sensing, 1–1,000 m |
| UV Sentry | Open-path UV-DOAS analyser for perimeter |
| Micro FTIR | Compact point FTIR analyser |
| Shepherd FTIR | Portable FTIR analyser, ppb, cryogenically cooled |
| Cerex FTIR | Point FTIR analyser with versatile housing, three variants: general, anaesthetic gases, CEM |
| FT-5000 | FTIR series for continuous emissions and processes |
| UV3000-P | UV-DOAS analyser with probe for in-stack measurement |
| UV3000 | UV-DOAS series with in-stack configurations: crossed path, rack, sample and area |
| Aeres-XL | Fixed, integrated UV-DOAS analyser, for stack or process |
| UV Scout | Fixed UV point analyser for BTEX and VOCs, 2–20 m internal path |
| UV Hound | Portable UV analyser for emergency response |
| UV-FTIR | Hybrid UV-DOAS and FTIR analyser for continuous emissions |
Where is Cerex Monitoring Solutions equipment used?
- Refineries and petrochemicals — perimeter monitoring for benzene, VOCs and BTEX
- Chemicals and fertilisers — NH3, Cl2 and SO2 in stacks and in process streams
- Flue gas cleaning — DeSOx and DeNOx, with a probe analyser in the stack
- Response to accidental releases — portable analysers for identifying the compounds released
How do we supply Cerex Monitoring Solutions in Romania?
We can prepare quotations for Cerex FTIR and UV-DOAS analysers, from open-path systems to stack systems. We supply the equipment to order; as these are systems configured for the application, the lead time is usually 1–4 weeks and can be longer for stack configurations or customised units. For a correct quotation we need the gases to be measured and the concentration ranges, the type of measurement (perimeter, point, stack or process), the gas temperature and humidity, the length of the measurement path and, for regulated emissions, the limits in the permit. The exact configuration and lead time are confirmed in the quotation.
Approval of a stack configuration for emissions reporting in Romania is checked step by step, based on the requirements of the environmental permit.
Frequently asked questions about Cerex Monitoring Solutions
What products does Cerex Monitoring Solutions make?
Cerex designs and manufactures multi-gas FTIR and UV-DOAS analysers in Atlanta: open-path AirSentry, portable point analysers (Micro FTIR, Shepherd FTIR, Hound series), fixed stack systems (FT-5000, UV3000, Aeres, UV-FTIR) and process analysers for closed streams.
How do I choose between FTIR and UV-DOAS for my application?
FTIR covers many compounds simultaneously, more than 350 in the FTIR library, including combustion gases and VOCs. UV-DOAS is suited to BTEX, NH3, Cl2 and SO2, with limits in ppb. The choice is made from the list of gases, not from a technology preference; send us the list and the ranges.
Do you supply Cerex analysers in Romania, and how quickly?
Yes, to order. The lead time is usually 1–4 weeks, but stack analysers and customised ones often need longer; the exact lead time appears in the quotation. The systems are configured for the application.
Can a Cerex analyser replace a network of point sensors?
For a perimeter, an open-path AirSentry monitors a path of 1–1,000 m and can replace several point sensors. The result is confirmed at each site; it depends on the target gases, the path and the weather, and we check the data before quoting.
What details should I give for a quotation on a Cerex analyser?
State the gases to be measured and the expected concentrations, the type of measurement (perimeter, point, in-stack or process), the path length or stack diameter, the temperature, humidity and dust in the gas, and the emission limits of the installation. For stacks, add the available power supply.
How do I request a Cerex Monitoring Solutions quotation?
Send the Cerex Monitoring Solutions code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Cerex Monitoring Solutions, LLC (manufacturer documentation)

