Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Focused Photonics (FPI) supplier in Romania

TDL and UV analysers, chromatographs and process mass spectrometers

Founded in 2002 · Headquarters: Hangzhou, China

Request a quote

Who is Focused Photonics (FPI) and what does it make?

Focused Photonics (FPI) was founded in 2002 in Hangzhou and makes analytical instruments for industry, the environment and the laboratory. From the portfolio, the process analysis line is of interest here: TDLAS laser analysers, UV analysers, industrial chromatographs, process mass spectrometers and total sulphur analysers. Alongside them are the emission monitoring systems (CEMS), used where legislation requires continuous reporting of stack gases.

The LGA range is based on laser absorption in the gas and measures directly in the duct or stack, without sampling, over optical paths of 0.5 to 20 m, with a response time under one second. It is used for HF, NH3, H2S and HCl and for applications such as ammonia slip after catalytic reduction in thermal power plants or HCl and HF in waste incineration. The OMA-3510 measures H2S, SO2, COS, CS2 and sulphur vapours in the tail gas of a Claus unit, by UV spectroscopy between 190 and 450 nm. The ProGC-3000 is a process chromatograph with programmed column switching, and the ProMars-6000 is a modular quadrupole mass spectrometer for several streams.

Such analysers are found in refineries, thermal power plants, cement plants and steelworks, incinerators and fertiliser plants. The series on the nameplate identifies the LGA, OMA or ProGC variants.

What do we supply from the Focused Photonics (FPI) range?

ProductDescription
LGA-4100In situ TDL analyser, in an ATEX version according to the manufacturer's documentation, for HF, NH3, H2S, HCl and other gases, with a 0.5–20 m optical path and online calibration. Used in selective NOx reduction, in waste incineration and in fertiliser plants.
OMA-3510UV analyser for H2S and SO2 in the tail gas of a Claus unit, supplied with a pressure-reducing probe and a sample conditioning system; it calculates concentrations by chemometric algorithms.
ProGC-3000 / 3500 / 3600Industrial gas chromatographs with programmed column switching and fast injection, for gases and vaporisable liquids from refining, petrochemicals, metallurgy, pharmaceuticals and energy.
UTS-2000Online analyser of trace total sulphur, by UV fluorescence, for natural gas, secondary gases from metallurgy and other industrial gases, in place of laboratory sampling.

Why Focused Photonics (FPI)?

  • In-duct TDLAS, without sampling — the LGA-4100 measures over 0.5–20 m with a response time under one second, useful in hot, dusty and corrosive gases
  • OMA-3510 for Claus units — pressure-reducing probe, sample conditioning and analyser in one system, with H2S, SO2, COS, CS2 and sulphur vapours in the same spectrum
  • UTS-2000 for total sulphur in gas or liquid — UV fluorescence, with no moving parts, for natural gas and secondary gases from metallurgy
  • ProGC-3600, 3500 and 3000 — industrial chromatographs with programmed column switching, for refining, petrochemicals, metallurgy and energy
  • ProMars-6000 with a modular design — analysis and pre-treatment modules adaptable to the application, for multi-component and multi-stream analysis

Which Focused Photonics (FPI) codes and series are requested most often?

CodeDescription
LGA-4100In situ TDL analyser, with optical paths of 0.5–20 m
LGA-4500TDL analyser with bypass for trace gases
OMA-3000Online UV spectrometer with optical fibre
OMA-3510SRU analyser for H2S and SO2
UTS-2000Online analyser of trace total sulphur
ProGC-3000Online industrial chromatograph
ProGC-3500Online industrial chromatograph
ProGC-3600Online industrial chromatograph
ProMars-6000Online industrial mass spectrometer
RLGD-100Remote laser detector for methane
GRD-2000Thermal conductivity gas analyser
CEMS-2000Continuous emission monitoring system: SO2, NOx, CO, CO2

Where is Focused Photonics (FPI) equipment used?

  • Refineries and petrochemicals — total sulphur, H2S and SO2 from sulphur tail gas
  • Thermal power plants — NH3 slip after SCR or SNCR
  • Cement and steelworks — process gases and secondary gases
  • Waste incineration — HCl and HF in flue gases
  • Fertilisers — NH3 and HF in chemical plants

How do we supply Focused Photonics (FPI) in Romania?

We can quote FPI analysers from the LGA, OMA, ProGC and UTS lines, with their sampling and conditioning systems. Equipment is ordered by configuration; the lead time is usually 1–4 weeks, and systems with a cabinet, probe and sample conditioning may need longer. For a quotation you need to state the gas and the measuring range, the temperature, the pressure and the dust content in the duct or in the sample, the length of the optical path, the classified area, the power supply and the signals required by the control system. Items can ship in 24–72 h when the item is in stock, locally or at the supplier; the exact lead time is shown in the quotation.

Documentation in Romanian and local spare parts for a specific configuration are checked before the quotation.

Frequently asked questions about Focused Photonics (FPI)

What products does Focused Photonics (FPI) make?

Gas analysers and analytical instruments: TDL for ducts and stacks (LGA), UV analysers for sulphur (OMA, UTS), process chromatographs (ProGC), mass spectrometers (ProMars) and emission monitoring systems (CEMS). The company is based in Hangzhou and was founded in 2002.

How do I choose between the LGA-4100 and the LGA-4500?

The LGA-4100 measures in situ, directly in the duct, without sampling, over 0.5–20 m. The LGA-4500 is the bypass version for trace gases and an extracted sample. The temperature, dust, pressure and concentration range decide the right version.

Do you supply FPI analysers in Romania and within what lead time?

Yes, to order. FPI analysers are supplied to order, usually in 1–4 weeks; accessories and parts can ship in 24–72 h when the item is in stock, locally or at the supplier. For systems with a probe, sample conditioning and cabinet, the lead time is set after configuration.

Can I replace an old H2S and SO2 analyser with the OMA-3510?

Interchangeability is confirmed on the basis of the data. Send the current model, the sampling point, the temperature and pressure of the tail gas, the length of the sample line and the output protocol, to see what can be reused.

What data are needed for a quotation on a ProGC chromatograph?

The components to be measured and their ranges, the type of sample (gas or vaporisable liquid), the number of streams, the pressure and temperature of the sample, the carrier gases available, the classified area and the protocol to the DCS.

How do I request a Focused Photonics (FPI) quotation?

Send the Focused Photonics (FPI) code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Focused Photonics Inc. (manufacturer documentation)